High Voltage Inclined Plane And Erosion Tester
SCR ELEKTRONIKS have developed HIGH VOLTAGE INCLINED PLANE AND EROSION TESTER to carryout test specified in many standard to cover test method for the evaluation of the relative tracking and erosion resistance of insulating solid using liquid contaminant (ASTM D2303). Perform the Initial Tracking Voltage Test, Time to track Test, And Erosion Test as per selection.
-
product
PXI/PXIe High Voltage Multiplexer, Single 48-Channel, 1-Pole
42-321-109-HI
The 40-321-109-HI (PXI) and 42-321-109-HI (PXIe) are single 48-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
Service, Modernization, and Calibration Serivices
In addition to production of new material testing machines, TIRA offers inexpensive service, modernisation and calibration. Our modular design makes it possible to modernise complete measuring technologies, electromechanical and hydraulic material testing machines in a cost-efficient manner.According to all requirements of force-measuring systems DIN EN ISO 7500-1, calibration DIN EN ISO/IEC 17025 and test options according to EN 10002.
-
product
AC Voltage Transducer
TD SERIES: AC
Kusam Electrical Industries Limited
• Dual Aux. Power 110/220V AC• High Accuracy 0.2% RO at 23 °C ± 5 °C• High Dielectric Strength 2.6KV AC / Min,Between Input / Output/ Power Case• ABS Plastic Case, DIN Rail or Wall Mounting
-
product
NIST Calibration for D610-A
D610-A-CCNIST
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
product
High Voltage DC Power Supply
IT6700H Series
IT6700H series high-voltage DC power supplies is with maximum output power 3000W, adjustable voltage 0-1200V and current 0-10A, IT6700H series have desktop and shelves installation function, easy to operate. IT6700H series provide list mode, built-in RS232 / USB / GPIB communication interface, rich SCPI instructions facilitate the formation of a variety of intelligent test platforms.
-
product
HIPOTS (High Voltage Testers) / AC Hipots
5 kV Digital
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Panel mounted controls & indicators. Variable from zero to 5 kV. Digital kV and leakage mA meter.
-
product
Temperature Calibration
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Micropower Voltage Reference
ISL21010
The ISL21010 is a precision, low dropout micropower bandgap voltage reference in a space-saving SOT-23 package. It operates from a single 2.2V to 5.5V supply (minimum voltage is dependent on voltage option) and provides a ±0.2% accurate reference. The ISL21010 provides up to 25mA output current sourcing with low 150mV dropout voltage.
-
product
High Voltage Linear Amplifier
A400X
This unit is a version of A400 amplifier equipped with two inputs, DC-offset and output atenuation. Input A is a normal non-inverting one. Using this input alone makes A400X functionally identical with A400 amplifier.Input B can act as a inverting or non-inverting depending on the position of the corresponding switch.
-
product
Sound Level Calibrator
511E
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
product
C Series Voltage Output Module
The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Replacement Alligator Clips for High Voltage Differential Probe
PK-HVA-01
Replacement Alligator Clips for High Voltage Differential Probe
-
product
High Voltage Test Equipment
A hipot test is conducted by ensuring no current flows from one point to another on a circuit. A hipot test will take two conductors that should be isolated from one another and passes a high voltage between the two points. The current which flows between these points is then measured. If too much current flows, this would indicate that the points are not well isolated and the test will fail.
-
product
Voltage Pulse Generator
SKS-IV10J
Shanghai Sanki Electronic Industries Co., Ltd.
The voltage pulse generator SKS-IV10J is completely designed in accordance with the requirements of the impulse voltage chapter in OIML R 46-1/-2; it meets the requirements of the new IEC60255-5 and GB14711 standards; the leakage current detection alarm function is added, and the leakage current limit can be Adjustment; using linearized high-voltage power supply, low noise, high stability, high voltage accuracy and long service life.
-
product
High Voltage 50 Ω Pulse Generator
TLP-8010A
High Power Pulse Instruments GmbH
*Wafer and package level TLP/HMM testing*Fast 50 Ω high voltage pulse output with typical 300 ps rise time*Up to 80 kW peak output power into 50 Ω load*Built-in HMM pulse up to ±15 kV with 50 Ω-configuration*High pulse output current up to ±80 A (short circuit) with 6 dB reflection suppression*High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)*6 GPIB programmable pulse rise times: 300 ps to 50 ns*1 built-in pulse width: 100 ns*Optional external pulse width extensions 5/10/50/100/200/500 ns using an external pulse width extender TLP-8012A5*Fast measurement time, typically 0.2 s per pulse including one-point DC measurement between pulses*Efficient software for system control and waveform data management*The software can control automatic probers for fast measurements of complete wafers*High performance and high quality components
-
product
Acoustic Calibration Services - IEC
Acoustic Calibration Services - IECMake sure you measure correctly! We offer traceable acoustic calibration services according to international IEC and ANSI standards and ensure that your instrument accurately indicates the required measurement parameters. Calibrations are documented, traceable, and digitally signed in cooperation with an accredited calibration laboratory.
-
product
Voltage Converters
Made from marine-grade aluminium extrusions or heavy-gauge aluminium sheet metal. Powder-coated or anodized, and use stainless fittings throughout Fitted with robust circuit boards using expensive heavy-gauge copper conductors, designed by Analytic Systems' engineers and assembled in our plant.Models are available to step-up, step-down, stabilize or isolate DC power over a range of 12 to 360 volts. No matter which unit you need, these easy-to-install Voltage Converters will give you many years of reliability.
-
product
AC DC High Voltage Divider
NMC make products are the ideal equipment for HV measuring products are the ideal equipment for HV measuring instruments, apply in power system, electronic equipment factory to test frequency AC high voltage and DC high voltage. This product is composed by HV measuring part and LV display instrument. HV part and LV display instrument are separate when working, it is safe and reliable.
-
product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-906-HI
The 65-231-906-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
Calibration Kit
N612
*N612 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Low Level, DC Voltage Data Logger
Volt101A
The Volt101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
-
product
Surge Voltage Generator
SSG 1100
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
product
Solid State Voltage Injector
J2110A
While it is possible to obtain high quality injection transformers with bandwidths as wide as 1Hz to 5MHz or more, in some cases this is still insufficient for some tests. For example a typical heater control loop might have a bandwidth of less than 1Hz while some linear regulators and opamp circuits can have bandwidths of up to 100MHz or in some cases even higher. For these applications, a solid state injector can provide the necessary bandwidth. A solid state injector can perform at DC, while the upper frequency limit is dictated by the components selected and the printed circuit board material and layout. It is possible to obtain a solid state injector with a working range of DC – 200MHz, though above 50MHz the interconnection between the injector and the circuit being tested can become quite critical. It is essential that ripple from the injector power supply does not dramatically degrade the dynamic range or the signal to noise ratio of the measurement. The resulting plots are often much cleaner when using a solid state injector than with a transformer injector.
-
product
Calibration Equipment
Tempsens offers a complete range of temperature calibration types of equipment for calibration of Contact Type Sensors (Thermocouple, RTD) and Non-Contact Type Sensors (Pyrometer). Our Calibration range is from -196°C to 3200°C
-
product
Calibration
The Young Calibration laboratory provides UKAS calibration (Laboratory 0604) services and testing to all industries whilst maintaining a reputation for quality, cost effectiveness and reliability.Water Flow Calibration, Oil Flow Calibration, Air Velocity Calibration, Humidity Calibration, Pressure Calibration, Temperature Calibration, Electrical Calibration, Mechanical Calibration, Automotive Calibration, Medical Calibration, On-Site Calibration,
-
product
Data-based Modeling and Calibration
ASCMO
ETAS ASCMO is the easy-to-use-solution for advanced model-based calibration and data-based modeling in significantly less time. ETAS ASCMO enables the fast and efficient development of accurate data-based models. Once created, these high-accuracy models can be used to optimize parameters of real systems such as engine ECUs or plant models in different simulation environments (e.g. Simulink or HiL-Systems). Both, steady state and dynamic/transient system behaviors can be captured.