Picoprobe
Line of microwave and oscilloscope probes, has served the on-wafer probing needs of the worldwide semiconductor industry, beginning with a line of high impedance troubleshooting probes for diagnostic studies of the internal workings of complex logic and memory chips.
- (239) 643-4400
- 239 643-4403
- email@ggb.com
- 4196 Corporate Sq
Naples, Fl 34104
United States of America
-
Product
Probe Cards
-
PICOPROBE® PROBE CARDS by GGB Industries, Inc., allows for more chip design flexibility because each probe card is custom configured to your circuit for testing wafers on either manual or automatic probe stations. Probe cards with complex layouts consisting of numerous DC contacts and multiple microwave probes with operating frequencies of 40, 50, 67, or 110 GHz can be custom fabricated quickly and inexpensively.
-
Product
Tungsten Probe Tips
T-4 Series
-
T-4 tips are for use in most standard commercial micropositioners for probing integrated circuits, pads, or lines. Each T-4 tip uses the same 10, 22, 35, 60, or 125 micron diameter tungsten wire as our Model 12C Picoprobe, but is mounted to a 0.020 inch diameter, 2 inch long tinned copper shaft.
-
Product
Microwave Testing
140
-
The PICOPROBE® MODEL 140, a high performance microwave probe which incorporates a WR-8 waveguide with our patented coaxial design techniques, has inherent low loss and low dispersion characteristics.
-
Product
Microwave Testing
75
-
The MODEL 75 PICOPROBE® sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 75 Picoprobe, with or without the bias T option, achieves an insertion loss of less than 1.0 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.
-
Product
Microwave Testing
220
-
The PICOPROBE® MODEL 220, a high performance microwave probe which incorporates a WR-5 waveguide with our patented coaxial design techniques, has inherent low loss and low dispersion characteristics.
-
Product
Dual Microwave Probe
-
The PICOPROBE® DUAL MICROWAVE PROBE consists of two separate probes mounted on a single holder. One probe is fixed to the holder; the other is adjustable. Each probe may be individually configured with GSG, GS, or SG footprints having any fixed pitch from 50 to 2540 microns. The probe to probe (signal to signal) spacing is user adjustable over a 4000 micron (160 mil) range. When ordering, an initial signal to signal spacing should be specified (up to .75 inches).
-
Product
Microwave Testing
120
-
The MODEL 120 PICOPROBE® sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics, the Model 120 Picoprobe®, achieves an insertion loss of less than 1.75 db (typical) and a return loss of greater than 15 db (max.) over its frequency range.
-
Product
Calibration Substrates
-
The GGB Industries, Inc., line of CALIBRATION SUBSTRATES allows the user to calibrate any GGB Industries, Inc., microwave Picoprobe® at the probe tip. The underlying principal of the calibration of a measurement system is to provide accurate known standards to which the measurement system can be connected
-
Product
High Impedance Active Probes
35
-
The Picoprobe Model 35 has been engineered to meet the stringent demands of advanced high frequency circuit designers.
-
Product
Microwave Testing
90
-
The PICOPROBE MODEL 90, a high performance microwave probe which incorporates a WR-12 waveguide with our patented coaxial design techniques, has inherent low loss and low dispersion characteristics.
-
Product
High Impedance Active Probes
18C & 19C
-
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
Product
Microwave Testing
1100B
-
The Model 1100B Picoprobe sets new standards in microwave probing performance. Benefiting from coaxial techniques, which have inherent low loss and low dispersion characteristics.
-
Product
High Impedance Active Probes
28 AND 29
-
Designed to serve the needs of integrated circuit engineers working in the most advanced high speed, submicron, MOS technology. These high frequency instruments include the attractive features of the Models 18C and 19 including full dc capability, negligible dc current drain, and extremely low input capacitance. In addition the frequency range of the Models 28 and 29 has been extended to a full 1 GHz.
-
Product
Microwave Testing
40A
-
The GGB Industries, Inc., MODEL 40A microwave probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 40A achieves an insertion loss of less than 0.8 db and a return loss of greater than 18 db through 40 GHz.
-
Product
High Impedance Active Probes
34A
-
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.















