PCB Piezotronics, Inc.
A manufacturer of piezoelectric quartz sensors, accelerometers, and associated electronics for the measurement of dynamic pressure, force, and vibration.
- 800-828-8840
716-684-0001 - 716-684-0987
- info@pcb.com
- 3425 Walden Avenue
Depew, NY 14043-2495
United States of America
-
Product
Precision Condenser Microphone
377C01
-
Performance:Nominal Microphone Diameter:1/4"Open Circuit Sensitivity 2.0 Open Circuit Sensitivity (3 dB)-54 dB re 1 V/PaFrequency Range Inherent Noise<35 Temperature Coefficient of Sensitivity (+14 to +122FHousing Material: Stainless Alloy
-
Product
Multi-Conductor Cables
-
16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.
-
Product
Low Noise Prepolarized Microphone
378A04
-
The 378A04 is a matched system that is comprised of a high sensitivity microphone and a low noise preamplifier that contains a built-in filter that enables the free-field response to remain flat over a wide frequency range. The system requires a minimum of 4 mA and measures to 6.5 dBA (5.5 dBA typical) within a cost efficient, prepolarized (0V) design. PCB's model 378A04, the industry's first prepolarized low noise microphone and preamplifier system allows you to measure extremely low amplitudes. In the past this was only possible with externally polarized solutions. With a typical noise floor of 5.5dBA, this microphone system delivers all of the benefits commonly associated with prepolarized systems.
-
Product
Building Acoustics
-
Measurements to evaluate and improve Building Acoustics are typically made to analyze and design noise control from room to room, or from outside to inside. Noise sources such as music systems, televisions, appliances, traffic, aircraft, and manufacturing are all around us. The field of Building Acoustics evaluates and designs the materials and methods to insulate and isolate us all from these sound sources when we are at work, rest, or enjoying leisure time. The resulting data is useful for evaluating compliance with building codes and for proposing countermeasures for areas of concern. These measurements often involve creating and measuring an artificial sound source, and then measuring the resulting noise in receiver locations.
-
Product
Dual-Mode Charge Amplifiers
-
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
In-line ICP® Charge Converters
-
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
Product
3-Component Quartz Force Links
261 Series
-
Three-component force links eliminate the preload requirement of 3-component quartz force ring sensors, and offers a convenient, 4-screw hole mounting plate on each side end the sensor. Quartz 3-component force links are constructed by installing a 3-component force ring sensor, under preload, between two mounting plates.
-
Product
Conformal Ballistic Pressure Sensor
Model: 117B44
-
Conformal ballistics pressure sensor, 243 Win, 260 Rem, 30-07, 308 Win (7.62 x 51 NATO), 338 Federal, 358 Win, 375 JDJ, 38-40 Winc, 44 S & W Special, 444 Marlin, 7.5 x 54Conformal ballistics pressure sensor for 243 Winchester, 260 Remington, 30-07, 308 Winchester (7.62 x 51), 338 Federal, 358 Winchester, 375 JDJ, 38-40 Winchester, 44 Smith & Wesson Special, 444 Marlin, 7.5 x 54 MAS, and 7 mm -08 Remington caliber cartridges.
-
Product
Ballistic Pressure Sensors
-
PCB® has supplied high frequency, durable, quartz ballistics pressure sensors in both charge and ICP® voltage mode versions for over forty years. Keeping with our tradition, PCB continues to offer a complete line of sensors for conformal and case mouth ballistic measurements. All PCB sensors are provided with NIST traceable calibration. For pre-calibration stabilization purposes, all ballistic pressure sensors are hydraulically cycled at high pressures and most are test fired in the PCB ballistic firing range.
-
Product
Miniature Triaxial Accelerometers
-
Miniature triaxial accelerometers are available in a variety of sensitivities to suit specific application requirements. These small and lightweight units have a high frequency response and minimize mass loading on test structures. They are ideal for installation in space restricted locations
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
PROBE MICROPHONE ICP
377B26
-