Kingrun Instrument Co., Ltd.
Measuring device for transmitting and converting high voltage. The professional high technology company collects scientific research developing,producing and sales for an inegral whole.
- +86-312-5959618
- +86-312-5926968
- kingrun.steven@gmail.com
- Building2# Torch High-Tech Park
Baoding City, 071000
China
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Transformer Short Circuit Impedance Tester
JYW6300
This instrument is mainly applicable to low voltage load impedance test of 35kV and above power main transformers (single phase or three phases) in ex-works routine tests, overhaul tests, pre-tests, and acceptance tests.
-
product
Contact Resistance Tester
JYL
As a high current passes through a pair of mechanically independent metallic contacts, the contact resistance must be as low as possible. Increasing the contact resistance of the contact often causes a large voltage drop on the contact, which reduces the input power of the load equipment. If the contact resistance of one or two contacts becomes large, the three-phase voltage of the load equipment will be unbalanced, causing phase loss operation.
-
product
Contact Resistance Tester
JYL-200B/100B
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
product
Transformer Performance Tester
6691
applying ±90V voltage on the winding of the transformer demagnetized and get the voltage value on the terminal and the current value in the winding to draw the hysteresis characteristic curve. This method can be used for linear quantitative analysis of residual magnetism in transformers, and fast demagnetization can be achieved by tracking hysteresis curves. The analyzer can measure magnetism residual rate before and after demagnetization.
-
product
Portable Winding Resistance Tester
1. Handheld winding resistance meter2. Conversion function for standard temperature resistance.3. 500 test data can be saved and download by flash disk.4. Temperature testing function.
-
product
Transformer Performance Tester
JYM
JYM insulation resistance tester is used for on-site insulation resistance measurement. The instrument has built-in positive and negative bipolar high-voltage power supplies, with large output power and strong load capacity. It is suitable for insulation resistance measurement of samples with large capacitance, such as power transformers and cables.
-
product
Partial Discharge Tester
GTPD-4C
GTPD-4C partial discharge comprehensive tester is the new generation of digital PD measurement and analysis instrument. The instrument has a strong ability of comprehensive analysis of partial discharge and detection of partial discharge in small signal and strong interference environment. With different accessories, it can measure and locate the partial discharge in any high voltage electrical equipment. It can realize testing the transformer partial discharge by applying the voltage on the three phases simultaneously.
-
product
Transformer Performance Tester
JYW6100
JYW6100 Transformer No-loads and On-loads tester power factor tester is suitable for loss testing of low power factory transformer such as amorphous alloy transformer, with high precision and data loc
-
product
Substation Series Testers
GTPD-92
Partial discharge(PD) is a pulsed discharge that produces a series of physical phenomena and chemical changes such as light, sound, electrical and mechanical vibrations in and around electrical equipment.
-
product
Transformer Heat Run Tester
1. Suitable for all transformers below 240MVA heat run test and winding resistance testing.2. Printing heat run data automatically.3. With double power supply, can test high voltage side and low voltage side simultaneously and test any operation respectively.4. With anti breakage protection function of inductive test items.
-
product
Capacitance and Inductance Tester
JY6700
Capacitance measurementsInstrument can test take a single capacitor without stitches in test group capacitance to bring convenience to test. It will show test results of capacitance while show test
-
product
Contacts Resistance Tester
JYK II
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
product
Transformer Degaussing Analyzer
KRI6691
The KRI6691 transformer degaussing analyzer injects current into the test winding by applying ±90V voltage, and collects the terminal voltage and winding current to draw the hysteresis characteristic curve. Linear quantitative analysis of transformer remanence can be performed, and rapid demagnetization can be achieved by tracking the hysteresis curve.
-
product
Substation Tester
JYH
JYH C CT PT Analyzer,full-featured, can not only satisfy the test requirements of various CTs (include TP class), such as the excitation characteristics (i.e., volt-ampere characteristics), ratio, polarity, secondary winding resistance, secondary burden, ratio error and phase displacement, but can also be used for the tests of various PTs, including excitation characteristics of the electromagnetic unit, ratio, polarity, secondary winding resistance, ratio error and phase displacement.