Laurel Electronics, Inc
Laurel Electronics, Inc. designs, manufactures and sells programmable digital panel meters, counters, timers, remote displays, transmitters and other instrumentation for demanding industrial applications.
- (714) 434-6131
- support@laurels.com
- 3183-G Airway Avenue
Costa Mesa, CA 92626
United States of America
-
Product
True AC RMS Panel Meter
-
The Laureate? True RMS meter offers a high accuracy 4 1/2 digit display for five voltage ranges and four current ranges. It is suited for AC applications where there is considerable distortion of current waveforms from nonlinear loading. The input is AC coupled to read only the AC component, such as ripple on a power supply.
-
Product
Quadrature Position & Rate Meter
-
Accepts low-level differential or single-ended 5 V logic level quadrature signals from shaft encoders to display scaled position or scaled rate. One, two or four transitions may be counted at a maximum combined rate of 250 kHz and be mathematically scaled to display in engineering units from -999,999 to +999,999. An analog output scaled to the display and relay outputs are optional.
-
Product
Wall-Mount Enclosure
Model BOX
-
Model BOX is a wall-mount / bulkhead enclosure which provides environmental protection to IP65 / NEMA-4X. It comes with a 1/8 DIN panel cutout (45 x 92 mm) and can be used with 1/8 DIN instruments with a depth up to 134.5 mm (5.30"). This includes all 1/8 DIN instruments sold by Laurel Electronics.
-
Product
Phase Angle Meter
-
Exceptionally fast response (up to 20 updates per second) and high accuracy for low frequencies, such as AC line frequency. A resolution of 1, 0.1 or 0.01 is user-selectable. Accuracy is 0.01% up to 100 Hz, 0.1% at 1 kHz, and 1% at 10 kHz.
-
Product
MAGNA Series "Large Digit" Elapsed Timers
Models TIM4 & TIM6
-
4-digit model (TIM4) with MM:SS or HH:MM display, or 6-digit model (TIM6) with HH:MM:SS display. Large-digit displays with a digit height of 2.2" (57 mm), 4.0" (102 mm), 5.7" (144 mm), 7.9" (200 mm), or 11.0" (280 mm) for long viewing distances. Optional relays and data I/O. Choice of display brightness and cases for indoor or outdoor mounting.
-
Product
2", 4", 6", 8" or 11" Large-Digit Displays
Grand Series
-
Available with 57 mm (2.2"), 102 mm (4.0"), 144 mm (5.7"), 200 mm (7.9"), or 280 mm (11.0") digit height for clock, timer, totalizer, frequency and rate inputs. RS-422 and dual-relay output options.
-
Product
Remote & Large Digit Displays
-
Remote and Large Digit Displays, as defined in this web page, are numeric displays that are driven by a serial signal from a computer, programmable controller, or other instrument. Digit heights can range from 0.56" (14.2 mm) to 11.0" (280 mm). Laureate remote displays, with a digit height of 0.56", are similar to a digital panel meter or counter in appearance.
-
Product
Batch Controller (analog input)
-
Same capabilities as the Laureate pulse-input batch controller, but for 0-1 mA, 4-20 mA, or 0-10 V process signals, as made possible by a built-in voltage-to-frequency (V-to-F) converter. Square root extraction is standard for use with flow meters.
-
Product
Duty Cycle Meter
-
Displays ON or OFF period as a percentage of total period over a programmed gate time from 10 ms to 199.99 s. A resolution of 1%, 0.1% or 0.01% is user-selectable. Applications include monitoring modulated proportional control systems and pulse-modulated systems, such as radar, lasers or packet radio.
-
Product
Splashproof Cover
Model IPC
-
Model IPC Splashproof Cover adds protection to IP67 / NEMA-4X from the front panel. It fits all of Laurel's 1/8 DIN instruments as well as 1/8 DIN instruments by other manufacturers, provided that instrument dimensions in front of the panel do not exceed 48 x 96 x 15 mm (1.89" x 3.78" x 0.59").
-
Product
Process Totalizer (analog input)
-
Displays and totalizes 0-1 mA, 4-20 mA, or 0-10 V process signals. Square root extraction is standard for flow applications, allowing display of volume from the 4-20 mA signal of a flow transducer with a linear or squared output.
-
Product
Scale / Weight Meter
-
Equipped with a DC or load cell signal conditioner, this Laureate offers special firmware for scale / weighing applications: two tare functions; count by 1, 2, 5, 10, 20, 50 or 100; auto-zero function; setpoint offset, and dummy right-hand zero for display to 999,990. Built-in excitation for up to four 350-ohm load cells in parallel.
-
Product
Laureate Duty Cycle Meter
Model FRD
-
Configured display ON or OFF period as a percentage of total period over a gate time from 10 ms to 199.99 s. A resolution of 1%, 0.1% or 0.01% is selectable. Ideal for repetitive short pulses with a pulse width down to less than 1 s.
-
Product
Totalizer (pulse input)
-
Two independent scalable pulse-input channels. Count up or down to a preset at rated up to 1 MHz. Scaled rate and total from the same electronic counter. Scaling for direct readout in engineering units, such as gallons or cubic feet based on counts from a turbine flow meter. One channel can display total while other displays rate.
-
Product
Process Meter & Totalizer
-
User-scalable for display to 999,999 for 0-1 mA, 4-20 mA, or 0-10 V process signals requiring zero and span adjustment. Ideal as flow rate meter or flow totalizer for analog flow meter signals. Includes 5, 10, 24 V transducer excitation output (user-selectable).