TEAM SOLUTIONS, INC.
Team Solutions, Inc. specializes in supplying computer-controlled, PC-based Test & Measurement, GPIB, Data AcQuisition, & Process Control solution-based instruments to industry, research, government, military & individual end-users. Our high-end, high-quality instruments are used by thousands of scientists, engineers, technicians & hobbyists world-wide.
- (949)338-8078
- sales@team-solutions.com
- 30322 Grande Vista Ave
Laguna Niguel, CA 92677
United States of America
-
Product
WiFiScope WS6-DIFF + SureConnect: 1 GS/s 250MHz BW, 4 Channel, Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-DIFF-1000XMS-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
Product
16-channel, 1GHz, 1Mb/ch USB Logic Analyzer Plus 8-Channel Pattern Generator
LA-Gold-16
-
A maximum sampling rate of 1 GHz is available on all channels. The LA-Gold-16 has a large data buffer of 1 Mega samples per channel for sampling rates of up to 500 MHz on all 16 channels. The large buffer allows long capture times at high sampling rates. The digital logger function is for capturing very slow varying signals, e.g. room temperature.
-
Product
GPIB PCI Mezzanine Card (PMC) Interface & Cable
GPIB-PMC-XL
-
The GPIB-PMC-XL is a PCI Mezzanine Card (PMC) GPIB controller card that converts any CPU card with PMC slots into a GPIB controller.It performs all the basic IEEE-488.1 functions such as talker, listener and system controller. The IEEE-488.2 compatible functions make it fully compliant with the IEEE-488.2 specification. In controller applications, you can control typically up to 15 devices (instruments). If operated as a talker/listener (device) interface it does exchange data and state information with the current controller-in-charge of the GPIB bus. The GPIB-PMC-XL lets Windows and Linux programs control GPIB devices.The flat ribbon cable has a standard GPIB jack on one end and a receptacle to be plugged into the GPIB card on the other end. The 30cm (12in) flat ribbon cable is included by Team Solutions, Inc.
-
Product
HandyScope HS5 + SureConnect: 500 MS/s 250MHz BW, 2 Channel, USB Digital Storage Oscilloscope, 40MHz AWG, Spectrum Analyzer, Voltmeter, Transient Recorder
HS5-540XMS-W5
-
The Handyscope HS5 is the first USB oscilloscope (USB powered) sampling at 500 MHz, with a 14 bits resolution and a 250 MHz bandwidth. This makes it possible to analyze very fast signals with very small amplitudes. The smallest distortions can be revealed due to the high resolution and bandwidth. Because of the deep memory (up to 64 MSamples on one channel), long record measurements are available for intermittent phenomena and Fast Fourier Transform calculations with over 32 million spectral lines can be performed. Using very fast FFT algorithms, an FFT with 1 million spectral lines can be performed within a second.
-
Product
Quadrature Signal Generator
TE5100-PCI
-
The TE5100 is a 100MHz Direct Digital Synthesized Signal Generator available in a 3U, CompactPCI or straight PCI format. The TE5100 generates Sine and ACMOS/TTL output signals simultaneously up to 100MHz in 1 µHz steps. Sweep, FSK, Chirp and Single Tone are generated on board. The virtual panel allows control up to 100MHz of all parameters. The TE5100 is equipped with a ±1ppm on-board TCXO clock and can accept an external clock source.
-
Product
Four Port RS-232 Interface
PCI-COM232/4
-
Serial ports: 4Configured: Address and interrupt configured through PCI BIOS and supplied driversMax. baud rate: to 460.8 Kbps, software selectable per channel for 115.2, 230.4, or 460.8KbpsSerial modes: 5, 6, 7, or 8 data bits; odd, even or no parity; 0, 1 or 2 stop bitsUART: 16C550 standardInterrupt Status: Each UART interrupt status read from any UARTís Scratchpad RegisterConnector: 37 position D-type with fanout cable to 4 DB-9 or DB-25 male connectorsPower: +5V only
-
Product
3-in-1 Analyzer: Logic Analyzer, Protocol Analyzer, Simple DSO
MSO2216B
-
3-in-1 Analyzer : Logic Analyzer, Protocol Analyzer, Simple DSO• PC-based, USB3.0 interface• 8 / 16 Channels(display digital and analog waveforms of the same channel)• Digital Inputs : 2 GHz Timing, 200MHz State Analysis (Max.)• Analog Inputs : 200 MS/s (Max.), Bandwidth 40 MHz• 8 Gb Memory (Max.)• PC RAM storage for streaming mode• Utility model patent of Taiwan number M601827
-
Product
WiFiScope WS6+SureConnect: 500 MS/s 250MHz BW, 4 Channel, Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
WS6-500XMS-W5
-
TiePie engineering has introduced the WiFiScope series oscilloscopes. The new range WiFi oscilloscopes can be used via an ethernet connection (LAN, WiFi or WAN) but also still with a USB 2.0 / 3.0 connection. The built-in battery gives the WiFiScope the possibility to perform fully wireless measurements. Measurements can then be performed completely galvanically isolated, and over long distances. This wireless PC-based data acquisition instrument offers the user more possibilities for measurement applications.
-
Product
PCI-Embedded Solution
MSX-Box-800
-
ADDI-DATA offers a brand new Embedded Solution for all measurement and control applications: the MSX-Box (Measurement Solution EXtended-Box).
-
Product
16-bit, 200KHz, 8SE/4DIFF Isolated Analog Input Board
APCI-3016-8
-
The APCI-3016 is a 16-bit analog input board for 3.3 V and 5 V PCI systems, with optical isolation and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.
-
Product
HandyScope HS6-DIFF With SafeGround: 100 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-100XMG-W5
-
- 1GS/s sampling and flexible resolution of 8-16 bit.- Four input channels up to 250 MHz analog bandwidth- Highly accurate 1 ppm time base- DC Accuracy of 0.25 % and 0.1 % typical- Very fast 200 MSamples per second USB streaming Data logger- Spectrum analyzer with 32 million bins- Optional SureConnect connection test on all channels- Up to 256 MSamples memory per channel
-
Product
Lacquered Digital I/O Board, 64 Optically Isolated I/O Channels, 24V
APCI-1564-LAC
-
*32 digital input channels, 24V, incl. 16 interruptible*32 digital output channels, 24V, 500 mA / channel*Optical isolation 1000V*Input and output filters*Watchdog, timer*After power/ON the outputs are reset to ì0î
-
Product
Digital Input Board, 32 Isolated Channels, 24V
APCI-1032
-
32 digital inputs, 24 V or 5 V, incl. 16 interruptible inputs Optical isolation 1000 V Input filters Protection against pole reversal
-
Product
Handyscope TP450-250XM-W5
TP450-250XM-W5
-
The Handyscope TP450 is a power quality analyzer, connected via USB to the computer. The advanced measurement software delivered by default contains Quick Setups that allow to start mains power logging measurements without specialized instrument knowledge. With the 450 V input range, the Handyscope TP450 can be plugged directly in a (110 - 230 V) wall socket to measure the mains voltage. No additional attenuator is required. Logging mains voltage can be done at a high rate of 250 thousand measurements per second, with a resolution of 16 bit, which is equal to a 5½ digit voltmeter. The Handyscope TP450 is an accurate voltmeter, but one that performs 5000 measurements on each cycle of the mains voltage, while a standard voltmeter performs 3 measurements per second. Even with the very high measurement rate of the Handyscope TP450, the mains voltage can be measured continuously for weeks, and afterwards each period of the mains voltage can be analyzed thoroughly. Using this fast continuous measuring method, no voltage peak or dip is missed, even if it lasts just a msec. The maximum measuring duration of the mains voltage is only limited by the available hard disk space. Measuring one week takes approximately 0.69 GB disk space. During a measurement, also RMS value and frequency are logged. It is possible to measure various properties, like e.g. Minimum, Maximum, Peak to peak, Mean, Variance, Standard deviation.
-
Product
LOW-PROFILE Bracket for Ines GPIB-PCI-XL & GPIB-PCI-E
BRKT-GPIB-LP
-
We remove the normal-height PCI hold-down bracket from the Ines GPIB-PCI-XL or GPIB-PCI-E, replacing it with the LOW-PROFILE bracket. We keep the normal-height bracket in exchange.