ZOLIX
Zolix was established since 1999 and has been a leading global supplier of opto-mechanics and spectroscopy in China. Have strong R&D ,Production,Sales,and after service team with many years experience of industry knowledge and expertise across a broad range of technologies.
- 86-10-5637 0168
- :86-10-56370118
- sally-liu@zolix.com.cn
- LDUV 68B, No. 16 Huanke Middle Rd
Golden Bridge Science and Technology Industrial Base, Zhongguancun Science Park Tongzhou Zone
Tongzhou District, Beijing 101102
China
-
product
Crossed-Roller Bearing Linear Stage ,25mm Travel XY,Sensitivity 1um
NFP-2462
Model:NFP-2462 Crossed-Roller Bearing Linear Stage ,25mm Travel XY,Sensitivity 1um DetailsSpec: Please refer to NFP-1462 Specification,It is combinated by 2pcs NFP-1462(C,SR,SL)
-
product
Crossed-Roller Bearing Linear Stage 13mm Travel,Sensitivity 2um
KSM13(A)-40
Model:KSM13(A)-40 Crossed-Roller Bearing Linear Stage 13mm Travel,Sensitivity 2um
-
product
Modular Raman Spectrometers
Multifunction confocal Raman microscopy system, based on new designed confocal microscopy techniques, with the ultra-low noise CCD camera latest advanced for Raman detection, highresolution spectrometer, attaining superior user friendliness and sensitivity.
-
product
Ball Bearing Linear Stage,13mm Travel, Sensitivity 3um
PSM13(A)-34
Model:PSM13(A)-34 Ball Bearing Linear Stage,13mm Travel, Sensitivity 3um
-
product
Crossed-Roller Bearing Linear Stage ,25mm Travel,Sensitivity 1um
NFP-1462
Model:NFP-1462 Crossed-Roller Bearing Linear Stage ,25mm Travel,Sensitivity 1um
-
product
Omni-λ200i Monochromators and Spectrographs
Omni-λ Series of imaging spectrographs and monochromators from Zolix Instruments are profession standard for researchers who demand the highest quality data. Zolix spectrographs and monochromators feature a very flexible design that can be configured for a wide range of applications & spectral range from UV to NIR.Your product description goes here.
-
product
Microscope Photoluminescence Spectrometer
Flex One
Photoluminescence (PL) is the light emission from a material under the excitation by ultraviolet, visible or near infrared radiation. In semiconductor luminescent property measurements, the sample (e.g. GaN, ZnO, GaAs etc.) was usually excited by a laser (with a wavelength of 325 nm, 532 nm, 785 nm etc.), and its PL spectrum is measured to analyze the optical physical properties, such as the band gap width etc.. Photoluminescence is a high sensitivity, non-destructive analysis method, which can provide the information about the structure, composition and surrounding atomic arrangement of materials. Therefore, it is widely used in physics, materials science, chemistry and molecular biology and other related fields.
-
product
Stepper Motor,Precision Linear Stages,Application for Labs
PSAXXX-11-X
Model:PSAXXX-11-X Stepper Motor,Precision Linear Stages,Application for Labs Stepper motor and RS232 interface combine with SC300,MC series controller, achieve automatical control. Grinding ball screw ,linear slide and elastic couplings adopt high-quality products ,provide quality assurance . The design of limited switches and zero switch protect products and supply convenience;Standard interface is convenient for singal’s output. The back of motorized stages has handwheel , it is for convenience for adjustment; Standard hole is so easy for combine with other units, ensure convenience for multi-dimensional system; standard stepper motor and DB9 interface, choose to any controller according to requiremment
-
product
Triple Monochromator/ Spectrograph
Omni-λTripple Series
Omni-λ 500 Triple Monochromator/ SpectrographThe Triple Monochromators/Spectrographs include three 500 mm focus monochromators which are with fine alignment. The first two monochromators as the dispersion subtraction are used to reduce the stray light. The third monochromator as dispersion sum configuration is used to improve the resolution. And each unit can work well as the monochromator, and the two unit can also be used as the double monochromator. The first and the second monochromator are the side entrance and double exits, the third monochromator is the double entrances and double exits, it is easy to connect the CCD and PMT, the single channel detectors. There are three import gratings in each monochromator, and the spectral range is located in deep UV region, the middle UV and visible region. Each grating reflectivity can be up to 70% in their spectral region. Mainly used in high grade Raman spectroscopy measurement, such as UV-resonance Raman spectroscopy.
-
product
Crossed-Roller Bearing Linear Stage 25mm Travel,Sensitivity 2um
KSM25(A)-65
Model:KSM25(A)-65 Crossed-Roller Bearing Linear Stage 25mm Travel,Sensitivity 2um Details&Spec: Please refer to KSM25(A)-65 Specification,It is combinated by 2pcs KSM25(A)-65 (C,SR,SL).
-
product
UFP series High Sensitivity Fiber Optic Alignment Stages
UFP
Model: UFP1A-LFeatures:• The linear stage has both coarse adjustment and fine adjustment, sensitivity is much better than 0.5um• The rotation stage sensitivity is much better than 23.4" • High stability
-
product
Stepper Motor ,High-Precision Linear Stages,Application for Labs
KSAXXX-11-X
Model:KSAXXX-11/12-X Stepper Motor ,High-Precision Linear Stages,Application for Labs KSA xxx-11/12 series high-precision motorized translation stages has adopted new structure and crafts ;.Application for motion fields which needs high linearity.For example :femetosecond laser experiment, laser processing,three-dimensional scanning measured system and so on.
-
product
Crossed-Roller Bearing Linear Stage ,13mm Travel,Sensitivity 1um
NFP-1461
Model:NFP-1461 Crossed-Roller Bearing Linear Stage ,13mm Travel,Sensitivity 1um
-
product
Crossed-Roller Bearing Linear Stage ,25mm Travel XYZ,Sensitivity 1um
NFP-3462
Model:NFP-3462 Crossed-Roller Bearing Linear Stage ,25mm Travel XYZ,Sensitivity 1um Details&Spec: Please refer to NFP-1462 Specification,It is combinated by 2pcs NFP-1462(C,SR,SL) and 1pc NFP-1462CZ(as vertcail stage)
-
product
Spectrographs & Monochromators
Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. More than 100 gratings for the best spectral range, throughput and dispersion to meet your applicationDSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioningOptional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuationInstallation and set-up through USB 2.0 computer interfaces Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programsZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up