optek
Turbidity Meters, Colorimeters, UV, pH and Conductivity sensors
- +49-(0)201-63409-0
- info@optek.com
- Emscherbruchallee 2
Essen, 45356
Germany
Categories
-
product
Electrochemical Converter
C800
The Control 800 series of electrochemical converters combines high performance digital conductivity and analog pH measurements with intuitive operation. It has been designed for easy integration into skids and panels to cover a wide range of bioprocess applications in both, conventional stainless steel and single-use systems.
-
product
Photometric converter
HC 4000
Dedicated to optek turbidity sensors the HC4000 provides high precision signal processing combined with flexible configuration of the measurement setup. Several scales, like FTU or EBC can be selected to display the photometric signal in common units with product and process control.
-
product
Universal Converter
C8000
Multi channel converter for all optek photometric and conductivity sensors and electrochemical pH electrodes. Flexible configuration of sensors, measuring ranges, units and product specific setups make the C8000 converter series a powerful device in process monitoring in both conventional and single-use systems.
-
product
Converter
556
The dual channel converter 556 provides continuous inline, real-time measurement and control of turbidity. The customer’s specific factory calibration of the converter can be configured in ppm (DE), FTU or EBC. Combined with an optek TF56-N scattered light sensor the 556 converter is a cost-saving measuring system, providing reliable process measurements.
-
product
Turbidity Sensor
TF56-N
The TF56-N sensor is an inline real-time device designed to measure light absorbance at 11° caused by interaction with process turbidity. As an NIR light beam is passed through a dynamic process stream, the sensor simultaneously measures the amount of light scattered at 11° and the remaining amount of un-scattered light at 0°.
-
product
Electroplating Bath Analyzer
optek’s electroplating analyzers are inline devices designed to measure plating solution’s metal concentration in real time. These analyzers can be designed to accommodate virtually any concentration range. Operationally, the analyzer passes a white light beam through the plating solution to be monitored. Then, light absorbance is measured at two distinct wavelengths, and the difference in light absorbance between the two wavelengths is equated to a plating solution concentration.
-
product
Turbidity Probe
AS56-N
AS56-N is a probe for direct installation into pipelines and vessels measuring NIR light absorption (Turbidity or Solids Concentration) in various liquid flow streams. Two optical path length choices allow the measurement range to meet the process control requirements.
-
product
Saybolt Color Analyzer
optek’s Saybolt color analyzer is a dual wavelength light absorption sensor. Operationally, the sensor passes a white light beam through the stream to be monitored, where light absorbance is measured at two distinct wavelengths. The measuring wavelength is set to focus on or near the peak absorbance point of the “yellowness” curve, while the secondary wavelength is chosen to compensate for any influence due to light scattering (window fouling, particulate, immiscible fluids, gas bubbles, etc.). Together, the sensor yields a repeatable and reliable true color number without any sample conditioning.
-
product
Absorption Probe
ASD12-N
The ASD12-N absorption probe has a durable LED light source for direct installation into laboratory bioreactors and disposable bioreactors for measuring cell growth and optical density. The probe is available in three different lengths to fit any vessel and is suited for sterilization / autoclaving procedures.
-
product
Color Sensor
AF16-F
High precision sensor for direct installation into pipelines measuring VIS or NIR light absorption of various liquid samples. Wavelength and optical path length can individually configured to meet the process control requirements with the highest accuracy.
-
product
Chlorine Dioxide Analyzer
optek’s chlorine dioxide (ClO2) analyzers are inline devices designed to measure real time ClO2 solution strength and/or ClO2 gas concentration . These analyzers can be designed to accommodate virtually any measuring range regardless of the stream’s phase. Operationally, the analyzer passes a white light beam through the ClO2 stream to be monitored, where light absorbance is measured at two distinct wavelengths.
-
product
Turbidity Sensor
AF56-N
AF56-N is a high precision sensor for direct installation into pipelines measuring NIR light absorption (turbidity) of various liquid samples. The optical path length can be individually configured to meet the process control requirements.
-
product
Conductivity Probe
ACS60-35
Knowing the conductivity of liquid samples is a key parameter to control product quality throughout the production process. The optek ACF60 conductivity probe fulfils technical requirements of international regulations for reliable measurements ensuring quality and consistency.
-
product
VIS/NIR Sensor
AF26
The AF26 is a high precision dual channel color sensor for inline operation; the secondary wavelength is designed to compensate the desired light absorbance measurement from any undesired light scattering influence, such as suspended solids, gas bubbles, immiscible fluids or window fouling. The AF26 sensor’s output can be correlated to almost any color scale including APHA and Hazen.
-
product
Color Probe
AS56-F
AS56-F is a probe for direct installation into pipelines and vessels measuring VIS light absorption of various liquid samples. Optical path length can individually configured to meet the process control requirements.