IET Labs
Manufacturer very high-quality instruments at competitive prices while providing a level of service not often found in the industry.
- (516) 334-5959
- info@ietlabs.com
- 99 Powerhouse Road
#302
Roslyn Heights, New York 11577
United States of America
-
Product
Inductance Standard
1482 Series
-
The GenRad 1482 Standard Inductors are the standard of choice in metrology labs. Used today by national metrology institutes and primary standards bodies around the world, these inductors have no peer or equivlent.
-
Product
Standard Capacitor
1409 Series
-
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
Product
Capacitance Bridge
1620
-
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
Product
Capacitance Standard
GenRad 1417
-
The GenRad 1417 Four-Terminal Capacitance Standard consists of a 1 F standard capacitor and two precise inductive voltage dividers used to scale the value of the 1 F capacitor up to 1 F in decade steps. This arrangement provides accuracy and stability unattainable with very high-value true capacitors.
-
Product
Micro-Ohmmeter
LOM-510A
-
The Micro-Ohmmeter has 4 digits, 0.02% basic accuracy and 1 resolution. The 4-terminal kelvin measurement connection minimizes lead resistance errors and 80 dB of ac noise rejection provides rock-steady readings even in noisy locations. The micro-ohmmeter comes with rugged 4-terminal test clips and a large selection of optional probes, clips and fixtures allowing attachment to any low-resistance unknown.
-
Product
Benchtop LCR Meter
1692
-
The GenRad 1692 LCR Meter is a sophisticated, microprocessor-controlled tester that brings new levels of flexibility, simplicity and accuracy to RLC measurement. It's testing automation at its best with a range of programmable test frequencies and test voltages, as well as automatic limit comparison, automatic parameter selection, remote programmability, automatic binning and automatic zeroing. The display facilitates visual acquisition of test data and eliminates costly guesswork and errors. The 1692 LCR Meter provides a powerful combination of features designed to maximize productivity in production testing applications.
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
High Power Resistance Decade Box
HPRS Series
-
The HPRS Series resistance decade boxes employ state-of-the-art precision resistors of various types for high accuracy, high stability, and low temperature and power coefficients of- resistance. High-power resistors within the unit are made available without sacrificing other electrical properties.
-
Product
Capacitance Bridge
1621
-
The GenRad1621 Capacitance Measurement system is a completely self-contained system capable of capacitance measurements in increments as small as 0.1 aF (10-4 pF) and conductance measurements in increments as small as 100 aU (10-7 U; equivalent to a shunt resistance of 1010 M). Measurements are three terminal, with 2- or 3-terminal connection, and provision is also made for the connection of an external standard for comparison measurements.
-
Product
LCR Meter
ET/QuadTech 1910/1920
-
The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
-
Product
Decade Capacitance Box
1412-BC
-
The wide capacitance range and high resolution of the GenRad 1412-BC decade capacitance box make it exceptionally useful in both laboratory and test shop. Owing to its fine adjustment of capacitance, it is a convenient variable capacitor to use with an Impedance Comparator. The polystyrene dielectric used in the decade steps is necessary for applications requiring low dielectric absorption and constancy of both capacitance and dissipation factor with frequency.
-
Product
Resistance Substitution Box
RS Series
-
The RS Series Resistance Substitution Box is the most commonly used decade box on the market today. The RS Series is not only easier to use, but it is also priced lower than most its competition.
-
Product
Resistance Decade Box
HARS Series
-
The HARS Series is the best choice when you need a laboratory grade, tight tolerance, high performance resistance decade box that is also cost effective.
-
Product
Decade Capacitor
GenRad 1423-A
-
The GenRad 1423 decade capacitor is a versatile tool for calibration laboratories and production-line testing. With it a bridge can be standardized to an accuracy exceeded only by that of the highest quality, individually certified laboratory standards such as the GR 1404 Reference Standard Capacitors.Used with a limit bridge, such as the GR 1689 Digibridge, the 1423 facilities fast and accurate production-line measurements of arbitrary capacitancevalues with minimum setup time.
-
Product
Decade Resistance Substituter Lab Standard
HARS-LX Series
-
The HARS-LX substituter is a precision resistance source with excellent characteristics of accuracy, stability, temperature coefficient, and power coefficient. All these features serve to make it a laboratory resistance standard, exceeded in performance only by stand-alone standard resistors.