Hilkar
Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
Categories
-
product
LV Iron Core Smoothing Reactors
Smoothing Reactors are serially connected reactors inserted in DC systems to reduce harmonic currents and transient over currents and/or current ripples in DC systems. They are necessary in order to smooth the direct current wave shape to reduce losses and improve system performance.
-
product
LV Iron Core Motor Starting Reactors
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
product
LV Iron Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Medium Voltage Iron Core Oil-Immersed Shunt Reactor
Iron core Oil-immersed Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system.
-
product
High Resistance Neutral Grounding Devices
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Sensing Resistors
Resistive Voltage Dividers
NGR Sensing Resistors are attached in parallel to the neutral grounding resistor. The sensing resistor allows a protective relay to detect a resistor failure in a continuous manner. Sensing Resistors are used in combination with neutral grounding resistor monitor relays. The relay measures neutral grounding resistance, neutral grounding resistor current and neutral to ground voltage. The relay continuously measures neutral grounding resistor ohmic value in an unfaulted system and it trips on if neutral grounding resistance varies from its calibrated value.
-
product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
product
Anti-Condensation Heaters
Anti-Condensation Space Heaters are designed to maintain the temperature of an electrical enclosure. Anti-Condensation Heaters are used for elimination of water vapor contained inside the enclosures. They also provide frost protection by keeping the internal temperature of electrical enclosure above the freezing temperature. The Anti-Condensation Space (Panel) Heaters prevent condensation through convection.
-
product
LV Iron Core Harmonic Filters
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
product
LV Iron Core Shunt Reactors
Iron core Shunt Reactors act as an absorber of reactive power to increase energy efficiency of the power system. Shunt Reactors are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. Shunt Reactors can be directly connected to the power line or to a tertiary winding of a three-winding power or distribution transformer.
-
product
Air Core Shunt Reactors
Shunt Reactors act as absorbers of reactive power to increase energy efficiency of the power system. Shunt Reactors are inductors that are used in order to compensate capacitive reactive power generated by long and lightly loaded transmission lines as well as underground cables, thus allowing the flow of more active power through the system and avoiding over voltages. The shunt reactors provide inductive compensation.
-
product
Radiator Mounted Load Banks
RD-Series
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Dynamic Braking Resistors
Speed of three phase asynchronous squirrel-cage motors and three phase synchronous motors are generally controlled by motor drives where frequency of the drive output determines the motor speed, and it can be adjusted without dependence on the voltage magnitude.