Current Sources
See Also: Programmable Current Sources, Battery, Voltage Current Sources
-
Product
Multichannel Source Measurement Unit
AXS844x
-
Run tests simultaneously on 4 channels with up to 400 V. Carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for direct testing of high-voltage RGBW LEDs
-
Product
Current Sensor For Outdoor Use
CT-41B
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Equivalent to protection grade IP67
-
Product
Directional Source
BAS003
-
The BAS003 Source is designed to generate homogeneous sound fields using random noise in compliance with the following standards: Building acoustics (insertion loss, acoustic absorption area, etc: ISO 140-3, ASTM E90, ISO 140-5, ASTM E966). The BAS003 is typically used to generate a noise in a free-field for the evaluation of the transmission loss index of a façade. The available high-efficiency power amplifier, BAS002, is light and can be remotely controlled for easy use in the field.
-
Product
Halogen & Deuterium Halogen Light Sources
-
Avantes Deuterium light sources are known for their stable output ad are used for UV absorption or reflection measurements. These can also be used as irradiance calibration sources due to their high stability. The standard AvaLight-DH-S mixes the halogen light with the Deuterium light, thus producing a wide spectral range light source. The output spectrum of Deuterium light sources exhibits several peaks, with a prominent peak at 656 nm. The AvaLight-DH-S-BAL incorporates a dichroic beam splitter installed to minimize these peaks, providing a smooth spectrum from 200-2500 nm.
-
Product
UV LED Light Source
Model 32
-
This new UV LED lightsource is designed and engineered by the proven lithography experts at OAI. The lightsource delivers a number of unique benefits, the most consequential of which is consistent intensity over an exceptionally long life. The lightsource is highly energy efficient, requires no maintenance or light replacement, and contains no mercury.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
42-514-102
Multiplexer Module
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
-
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
Product
PXIe-4162, 12-Channel, ±24 V, Precision PXI Source Measure Unit
785680-01
Analog Input Module
PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. It also features guard terminals to remove the effects of leakage currents and parasitic capacitances. Additionally, the PXIe-4162 can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4162 is ideal for a broad range of mixed-signal integrated circuits (ICs) in semiconductor production test.
-
Product
6000 Series ATE(AC Source)
-
Voltage output has totally six ranges,maximum up to 500V,convenient for 300V above the voltage regulation test
-
Product
AC to AC Non-Programmable Power Sources
AFC Series
-
CEHCO can supply AC to AC Non-Programmable Power Sources. We offer standard or customized solutions. The AFC Series is from 500 VA to 2000 KVA.
-
Product
Current Measurement in a Compact Design
ICD-Series
-
Isabellenhütte Heusler GmbH & Co. KG
The ICD series is a compact system for current measurement. The ICD-A is suitable for an application in the automotive industry due to its connector, while the ICD-C is more suitable for the design industry. The shunt-based measurement provides for a high level of accuracy and temperature compensation is also incorporated through the internal signal processing. External temperature influences are thus reduced to a minimum.
-
Product
Dual Mobile Communications DC Source w/ DVM
66309D
DC Power Supply
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections.The Keysight 66309D dual output mobile communications dc source provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a half rack box) and eliminates the need for two separate power supplies.The 66309D dc source provides all of the capabilities of the 66309B with the addition of a built in digital voltmeter.
-
Product
AC Current / Leakage Digital Clamp-on Tester
MCL-500DFN
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
MCL-500DFN AC Current / Leakage Digital Clamp-on Tester
-
Product
NI-9476, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module
785045-01
Digital Module
36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module - The NI‑9476 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 36 V,based on the external power supply, and features transient overvoltage protection between the output channels and the backplane. You can programmatically monitor the built-in overcurrent and short-circuit protection status of each channel.
-
Product
True RMS Current Clamps
-
PeakTech Prüf- und Messtechnik GmbH
Current clamps are ideal for current measurement in electrical systems and control cabinets, since only single wires are guided through the clamp jaws for contact-free current measurement and no electrical connections have to be disconnected. In addition, this model has extensive multimeter functions for voltage, resistance, frequency, capacitance and temperature measurement.
-
Product
NI-9470, 5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module
787089-01
Digital Module
5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module - The NI‑9470 is a digital output module that features proportional valve drive control. You can use the NI-9470 to perform pulse width modulation (PWM), dither control, and current readback. The NI‑9470 features eight output channels compatible with signals from 5 V to 30 V and transient overvoltage protection between the output channels and the backplane.
-
Product
AC and DC Non Inductive Current Shunt
Series A co-axial shunt and Option 02F/B shunt
-
Use with wattmeters, DMMs and power analyzers to extend current measurement ranges. Use with phase angle meters to enable phase angle measurements between voltage and current. Ultra low phase shift
-
Product
High Current 45 Relay PXI Card
GX6315 Series
Relay
The GX6315 is a 45 channel, high current relay board that plugs directly into any 6U PXI slot. The GX6315 also provides nine transistor-driven channels for external relays. These outputs may be used to drive external loads, such as heavy duty relays, lamps or other devices.
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. -
Product
For Detecting Low Range And Leakage AC/DC/Pulsed Current.
FDAZCT-20L-0.6S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Lowest Influence from Magnetization,Temperature *Change,Residual Current and Terrestrial Magnetism.*Low Cost and High Performance (Output Linearity ±1% F.S)
-
Product
30 Amps, 100 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP031
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Optical Light Sources
-
A fiber optic source is commonly used with a meter to measure optical fiber attenuation or insertion loss.
-
Product
Digital Volt Or Current Meter
CS1/CS2-VA
-
Measuring Voltage or Current for DC / AC / TRMS Accuracy: DC: +/-0.04% or AC: +/-0.1%; Display range: -19999~29999 User function, Easily programmable via the front panel. 1 relay, 1 Analogue output or RS 485 communication port in option with flexible functions. CE approved
-
Product
Three-Phase AC Power Source 320 Vrms, 3 KVA, 5000 Hz
AC6903H
Power Supply
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
Product
Emissions Reference Source (ERS)
Emissions
-
The ERS is a comb generator that radiates RF continuously every 2MHz over the range 30MHz - 1000MHz. Each 2MHz peak is precisely measured during the calibration process with the ERS orientated both vertically and horizontally. These measurements are correlated against a 3m OATS such that any fully implemented CISPR16 site, measuring at 3m and using height scanning, will read the same.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
40-514-102
Multiplexer Module
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
High Power Programmable AC Source With Transients
-
Chroma Systems Solutions, Inc.
Ideal for commercial, power electronics, avionics, military, and regulation test applications from bench-top R/D design verification to quality assurance and mass production
-
Product
High DC Primary Current Injection Test Set
PDC15k
-
PDC15k High DC Primary Current Injection Test Set adopts high-frequency invert principle to realize the high DC current output capability, with very small size and light weight. PDC15k is modular designed with changeable modules and multi-functions local control software.
-
Product
Closed Loop Precise Hall AC/DC Current Sensor
CYHCS-LF
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for accurate measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
-
Product
Noise Source, 1 GHz up to 50 GHz
346CK01
-
The Keysight 346CK01 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 50 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty, which are reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 20 dB at 1 GHz, decreasing to typically 7 dB at 50 GHz.