Quartz Crystal Microbalance
-
Product
Quartz Crystal Microbalance
-
Determining moisture concentration in natural gas, industrial gases or process gas is critical to many applications. QCM and electrolytic analyzers deliver fast, reliable and cost-effective measurements that support these processes.
-
Product
Quartz Crystal Microbalance
QCM200
-
Stanford Research Systems, Inc.
The QCM200 Quartz Crystal Microbalance measures mass and viscosity in processes occurring at or near surfaces, or within thin films. This system includes a controller, crystal oscillator electronics, crystal holder, three quartz crystals, and Windows / Mac software.
-
Product
Open-Source Quartz Crystal Microbalance
-
The sensor is a surface sensitive quartz crystal capable of measuring phenomena at molecular scale. It works in vacuum, air and liquid environments. The QCM sensor is based on the piezoelectric properties of the quartz crystal. The application of an alternating current causes the mechanical vibration of the quartz crystal in the MHz range. The QCM technique measures the variations in quartz frequency for measuring the mass variations on its surface.
-
Product
EQCM Electronic Quartz Crystal Microbalance
Elettra
-
Elettra has been designed to operate on its own, but it is also possible to connect it to a PC to control it and acquire, view and save data thanks to its extremely easy to use software that runs under MS-Windows™. The data acquisition process can be controlled extremely quickly thanks to the PLAY, PAUSE and STOP keys.
-
Product
Differential Quartz Crystal Microbalance
Dike
-
During an experiment to detect an affinity reaction on biological material, a molecule of interest is attached to the quartz crystal of the measurement channel, this deposition can be achieved by direct binding or by capture through another protein, the result of this process is to make the quartz sensitive to the molecule to be detected.
-
Product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
-
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
Product
Flow Cell Kit
QCMT
-
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
Product
Moisture Analyzer Series
3050
-
The 3050 series of moisture analyzers utilizes AMETEK’s proven, accurate quartz crystal microbalance (QCM) technology. Built-in verification provides operators with increased measurement confidence.
-
Product
Quartz Crystals
-
Quartz crystal resonators are used in a wide range of electronic applications that require timing devices. The quality of the quartz crystal blank is critical to the performance of quartz crystal units and the high Q factor of quartz means that tight stabilities can be achieved; this is key to ensuring microprocessor timing circuits work correctly within customer’s designs.
-
Product
QUARTZ
-
Quartz – Time Tracking for Jira is a product of QARA Enterprise. It’s an advanced time-tracking tool that extends the power of Jira by adding powerful time management capabilities. The add-on supports powerful time reports, painless time entry, custom attributes, approval process and more. It is available for download on the Atlassian Marketplace.
-
Product
Phase-Locked Crystal Oscillator
PLXO Series 0.9” x 0.9” x 0.25”
-
*Compact Surface Mount Package *Excellent Phase Noise and Stability *Configurable for any application
-
Product
Quartz Sensor Fiber Head
SLG-1001
-
Pure quartz fiber stands aving high UV transmission properties are used. This is the quartz sensor fiber head exclusive for the UV MONITOR SERIES excelling in flexibility and durability. The exclusive use receptacle for the light receiving inlet is also available.
-
Product
Temperature compensated crystal oscillator
TCXO
-
A TCXO (Temperature compensated crystal oscillator) is a crystal oscillator with a temperature-sensitive reactance circuit in its oscillation loop to compensate the frequency-temperature characteristics inherent to the crystal unit. Epson's are classified into two types. One is a Direct-Type TCXOwith a temperature compensation circuit built into the oscillation loop. The other is an Indirect-Type TCXO with a temperature compensation circuit outside the oscillation loop, in which the oscillation frequency is therefore indirectly controlled.
-
Product
Electro-Optic OH1 Crystals
-
OH1 and other high-quality organic crystals are produced and optically prepared in the facilities of Rainbow Photonics in Switzerland.
-
Product
3-Component Quartz Force Links
261 Series
-
Three-component force links eliminate the preload requirement of 3-component quartz force ring sensors, and offers a convenient, 4-screw hole mounting plate on each side end the sensor. Quartz 3-component force links are constructed by installing a 3-component force ring sensor, under preload, between two mounting plates.
-
Product
Electro-Optic DAST Crystals
-
DAST and other high-quality organic crystals are produced and optically prepared in the facilities of Rainbow Photonics in Switzerland.
-
Product
Voltage Controlled Crystal Oscillators
VCXOS
-
Voltage Controlled Crystal Oscillators (VCXOs) are used for fine adjustment of the operating frequency and are normally used in conjunction with a phase locked loop.
-
Product
Miniature Quartz Force Sensors
-
Often the test engineer will try to take low level measurements with a sensors not rated for these low levels. Due to insufficient sensitivity the resulting data may be noisy, hard to analyze or unusable. Using the appropriately sized and ranged PCB Miniature Quartz Force Sensor solves the problem and gives reliable data at a Low Amplitude level. The miniature sensor configuration permits low-amplitude, dynamic compression, tension, and impact force measurements.
-
Product
Electro-Optic DSTMS Crystals
-
DSTMS and other high-quality organic crystals are produced and optically prepared in the facilities of Rainbow Photonics in Switzerland.
-
Product
Liquid Crystal Thermographic Analysis Tool
thermVIEW
-
Advanced Thermal Solutions, Inc.
thermVIEW is a high resolution liquid crystal thermography system for cost effective temperature measurement of electronic circuit boards, micro circuits, hybrid components and integrated circuits. One micron level* thermal mapping of electronic devices.
-
Product
Quartz ICP® Links
-
Link-style sensors measure dynamic compression and tension. They are constructed using a force ring that is under compressive pre-load between threaded mounting hardware. The threaded mounting on both ends of the sensor supports integrated link-style installations. Versions offering full-scale measurements of 10 lb to 50k lb (45 N to 220k N) compression and 30k lb (130k N) tension are available.
-
Product
Single Crystal Films
YIG
-
Due to their very low microwave losses, single crystal ferromagnetic materials such as Yttrium Iron Garnet (YIG) and doped YIG are used for devices in microwave technology.
-
Product
Glass Sealed Electrolytic Cell With Quartz Optical Window
SWO-1
-
SWO-1 Glass Sealed Electrolytic Cell with Quartz Optical Window is an electrochemical cell for laboratory research, designed for three-electrode testing, sealed or unsealed experiments, photocatalysis, corrosion studies, optical observation, or customized electrochemical workflows depending on the selected model.
-
Product
5μm Transparent Quartz Interdigitated Electrode Chip
TIF1
-
5μm transparent quartz IDE chip designed for MEMS, biosensing, gas sensing, electrochemical, and photoelectric applications.
-
Product
2210A & 2211A Quartz Frequency Standards
-
Precise Time and Frequency, Inc.
The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.
-
Product
5μm Transparent Quartz Interdigitated Electrode Chip
TIM1
-
5μm transparent quartz IDE chip designed for MEMS, gas sensing, bioelectrochemical, and photoelectric applications.
-
Product
Quartz Electrolytic Cell Series | 30ml–300ml Square Fused Cells
QSE1
-
QSE1 Quartz Electrolytic Cell Series for electrochemical experiments, spectroelectrochemistry, corrosion testing, and high-temperature laboratory applications. Available in round and square fused quartz configurations from 30ml to 300ml and 50×50×50mm to 80×80×80mm sizes, including sealed, gas-welded, integrated, and bench stand versions. High-purity fused quartz provides excellent chemical resistance, high-temperature stability, and optical transparency for advanced electrochemical research systems.
-
Product
Quartz Crystall Oscillators
-
Superior crystal oscillator precision is required for both time and frequency in precision instrument applications such as synthesizers, counters and spectrum analyzers.
-
Product
3-Component Quartz Force Rings
260 Series
-
Three-component quartz force ring sensors are capable of simultaneously measuring dynamic force in three orthogonal directions (X, Y, and Z). They contain three sets of quartz plates that are stacked in a preloaded arrangement. Each set responds to the vector component of an applied force acting along its sensitive axis. 3-component ring force sensors must be statically preloaded for optimum performance. Preloading provides the sensing elements with the compressive loading required to allow the proper transmission of shear forces. Versions are available with ranges up to 10k lb (45k N) in the z-axis (perpendicular to the top surface), and up to 4000 lb (18k N) in the x-and y (shear) axes. Both ICP® and charge output styles are available.





























