-
product
High Density, 64-Channel Switch Card - 64 Channel, SPDT, High Isolation, Low Crosstalk Switch Module
1260-16A
The Astronics 1260-16A is a 64-channel, SPDT, high isolation; low crosstalk switch module designed for switching and routing sources such as AC and DC power supplies in automated test systems. The 1260-16A switches currents up to 6A, AC or DC, and voltages up to 110VDC or 250VAC.
-
product
PXI 24 x DPST Reed Relays
40-115-122
Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.
-
product
Signal Path Analyzers
HL5200 Series
HYPERLABS HL5200 Series Signal Path Analyzers™ provide ESD-robust, multi-channel test and measurement capabilities for a fraction of the cost of traditional benchtop systems. These differential instruments have up to 20 channels and can be used to take TDR, TDT, and XT (crosstalk) measurements. Beginning in June 2015, S-parameter (S11/S21) data will also be available.
-
product
High Temperature Axial Torsional Extensometers (1200 C or 1600 C)
Model 7650
Jinan Testing Equipment IE Corporation
Model 7650 extensometers are primarily used on round specimens tested in bi-axial test machines capable of simultaneous axial and torsional loading. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to minimize crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.
-
product
Quad 4 to 1 50 600MHz PXI RF Multiplexer
40-760-004
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Single 8 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-763A-001
The 40-763A-001 terminated single 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Cable, 25 Pin 1.27mm Pitch Micro-D, Female to Unterminated, Cut Ends, 1m
A025CFR-C-5A100
This 1m long female 25-Pin Micro-D to unterminated (with cut ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product. This cable assembly is suitable for high density applications including connection to Pickering's LXI DIO/Trigger port.
-
product
Dual 16 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-765-002
This terminated dual 16 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Performance Board For LSI Tester
Place inner layer GND plane all over. Impedance control of signal line and crosstalk prevention, etc. contribute to improvement of characteristics in various ways.
-
product
Cable, 25 Pin 1.27mm Pitch Micro-D, Female to Unterminated, Tinned Ends, 0.5m
A025CFR-T-5A050
This 0.5m long female 25-Pin Micro-D to unterminated (with tinned ends) cable assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connector to its associated product.
-
product
High Temperature XY Planar Biaxial Extensometer 1200 C or 1600 C)
Model 7651
Jinan Testing Equipment IE Corporation
Model 7651 extensometers measure combined in-plane strains in flat cruciform specimens tested in machines capable of simultaneous X and Y (perpendicular) axial loading and on standard flat samples tested in pure tension. All models are capable of bi-directional displacement in both axes and may be used for strain-controlled fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7651 models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to eliminate crosstalk between axes and to provide high accuracy, high resolution measurements. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods with conical rod tips for specimen contact when testing to 1200℃(2200°F). Silicon carbide rods are used for the 1600℃(2900°F) high temperature option.
-
product
Cable, 25 Pin 1.27mm Pitch Micro-D, Female to Female, 0.5m
A025CFR-025CFR-5A050
This 0.5m long female to female 25-Pin Micro-D Cable Assembly is constructed from 18/0.1 (26 AWG) copper wiring with PVC insulation and screening to minimise crosstalk. Screwlocks are provided to secure the connectors to their associated products. This cable assembly is suitable for high density applications including connection to Pickering's LXI DIO/Trigger port.
-
product
Cable 100-Pin Micro-D Male to Unterminated, Tinned Ends, 2m 2-56 UNC Screwlocks, Metal Shell
A100SMR-T-9A200
This 2m long male to unterminated 100-Pin SCSI Style Micro-D Cable Assembly is suited for direct connection to various products using the 100-Pin connector. It is constructed from 100-Pin twisted pair cable with varying left and right hand lays to minimise crosstalk. The Cable is colour coded to ensure easy connection. Screwlocks are provided to secure the SCSI connector to its associated product.
-
product
Cable 100-Pin Micro-D Male to Unterminated, Cut Ends, 2m 2-56 UNC Screwlocks, Metal Shell
A100SMR-C-9A200
This 2m long male to unterminated 100-Pin SCSI Style Micro-D Cable Assembly is suited for direct connection to various products using the 100-Pin connector. It is constructed from 100-Pin twisted pair cable with varying left and right hand lays to minimise crosstalk. The Cable is colour coded to ensure easy connection. Screwlocks are provided to secure the SCSI connector to its associated product.
-
product
Multi-Axis Sensors
Multi Axis Load Cell are designed and manufactured by Interface to measure a multiple of forces and/or moments simultaneously with a single load cell sensor. These sensors provide multiple bridges that precisely measure the applied force from one direction with little or no cross-talk from the other forces or moments - when installed and used according to specifications.
-
product
Multispectra, Multifiber, Multichannel Imaging spectrometer with 8-16-32 Simultaneous UV-NIR Spectra
PoliSpectra® M116 MultiTrack Spectrometer
HORIBA designs and manufactures a large range of custom OEM fiber-coupled, multi-spectra spectrometers capable of simultaneous measurement of up to 32 fiber channels and sequential measurement up to 96. Utilizing a concentric imaging spectrometer with a broadband spectral range and a customized fiber bundle, the HORIBA OEM multifiber spectrometers provide excellent imaging quality with minimum crosstalk.
-
product
Dual 8 to 1 50 600MHz PXI RF Multiplexer
40-762-002
This dual 8 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Transceiver
SDRlab 122-16
It comes with two 16-bit 50-ohm inputs and 14-bit 50-ohm outputs, Xilinx Zynq 7020 FPGA for real-time processing capabilities plus an ultra-low phase noise 122.88MHz clock which makes it more hardware-compatible with HPSDR compliant applications. RF inputs are optimized for minimal distortion, noise and crosstalk which significantly improves reception and broadens the choice of antenna.
-
product
Temperature Measurement IR Sensors & Detectors
DR34 Compensated
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
product
Multi Axis Load Cells
Multi-Axis Sensors are designed to measure a multiple of forces and moments simultaneously with a single load cell sensor. These sensors provide multiple bridges that precisely measure the applied force from one direction with little or no cross-talk from the force or moment.
-
product
Optical Switch
FTBx-9150
With crosstalk of –80 dB and life expectancy of 10 million cycles, the FTBx-9150 Optical Switch is ideal for bidirectional component testing, ribbon fiber testing, multichannel monitoring, remote and multiple-component testing, signal routing and bypass switching. Housed in the LTB-8-based test systems, the FTBx-9150 provides highly accurate and repeatable fiber-to-fiber switching. It offers a choice of 1x2, 1x4, 1x8, 1x12, 1x16, 1x24, 1x32, 2x2 and 2x4 configurations. Designed for minimal reflectance, the switches integrate precision optical components into a compact modular package. Both singlemode and multimode versions are available and offer a solution for all your optical switching needs.
-
product
C Series Voltage Output Module
The C Series Voltage Output Module helps you update analog output models that feature overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST-traceable calibration. This module includes up to 16 channels. Some models include a channel-to-earth ground double isolation barrier for safety and noise immunity as well as improved signal quality, and some higher density models conserve chassis space, which leaves room for other measurement types.The C Series Voltage Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Quad 4 To 1 Terminated 50Ω 600MHz PXI RF Multiplexer
40-761A-004
The 40-761A-004 terminated quad 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
Cable 96-Pin Female to 100-Pin Male Micro-D, 0.5m
40-973B-096-0.5m-FM
The 96-Pin to 100-Pin SCSI Style Micro-D Adaptor Lead is constructed from 7/36 (28AWG) Tinned Copper twisted pair wiring with Polyolefin insulation to minimise crosstalk. Metal Spring Latches are provided on the 96-Pin connector and 4-40 UNC screwlocks on the 100-Pin connector.
-
product
Cable 100-Pin Micro-D Male to Unterminated, Tinned Ends, 0.5m 2-56 UNC Screwlocks, Metal Shell
A100SMR-T-9A050
This 0.5m long male to unterminated 100-Pin SCSI Style Micro-D Cable Assembly is suited for direct connection to various products using the 100-Pin connector. It is constructed from 100-Pin twisted pair cable with varying left and right hand lays to minimise crosstalk. The Cable is colour coded to ensure easy connection. Screwlocks are provided to secure the SCSI connector to its associated product.
-
product
100 Pin Micro-D Cable, Male to Male, 1m 2-56 UNC Screwlocks, Metal Shell
A100SMR-100SMR-9A100
This 1m long male to male 100-Pin SCSI Style Micro-D Cable Assembly is constructed from 7/36 (28 AWG) Tinned Copper twisted pair wiring with Polyolefin insulation to minimise crosstalk. Screwlocks are provided to secure the connectors to their associated products. This cable assembly is suitable for use with Pickering BRIC modules that use the 100-pin Micro-D connector.
-
product
2-Module ICT System, I317x Series 6
E9902G
Keysight's family of i3070 Series 6 In-Circuit Test (ICT) systems are built on a proven technology foundation, and they improve test efficiency with time-tested software, hardware, and programmability. I3070 Series 6 ICT tester supports a wide range of printed circuit board assembly (PCBA) sizes for applications including IoT and 5G, as well as automotive and energy. The i3070 features a unique design that delivers the shortest signal path between measurement circuitry and devices under test to minimize undesired effects from parasitic capacitance, improve immunity to crosstalk, and eliminate stray signal coupling effects, delivering consistent and repeatable measurements. The Series 6 is fully backward compatible with previous systems and makes highly repeatable measurements.
-
product
Single 16 to 1 50 600MHz PXI RF Multiplexer
40-764-001
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.
-
product
100 Pin Micro-D Cable, Male to Male, 0.5m 2-56 UNC Screwlocks, Metal Shell
A100SMR-100SMR-9A050
This 0.5m long male to male 100-Pin SCSI Style Micro-D Cable Assembly is constructed from 7/36 (28 AWG) Tinned Copper twisted pair wiring with Polyolefin insulation to minimise crosstalk. Screwlocks are provided to secure the connectors to their associated products. This cable assembly is suitable for use with Pickering BRIC modules that use the 100-pin Micro-D connector.
-
product
Active Antenna Combiner
M2C
The M2C active antenna combiner is designed as an ideal matching component to Lectrosonics digital transmitters. Up to eight transmitters can feed a single antenna to minimize cabling in multi-channel systems. The inputs are isolated to minimize crosstalk and IM (intermodulation) between RF channels.





























