Radio Frequency
3 kHz to 300 GHz or a frequency < microwave.
See Also: Radio, Software Defined Radio, Ham Radio, Mobile Radio, RF, Microwave, VHF
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Bulk Current Monitoring Probe
MP-50
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
product
K-50 Series Probes
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
product
Frequency Meter, 3.7 to 12.5 GHz
537A
The Keysight 537A direct-reading frequency meter measures frequencies from 3.7 to 12.5 GHz quickly and accurately. Its long scale length and numerous calibration marks provide high resolution. This is particularly useful when measuring frequency differences or small frequency changes. Frequency is read directly in GHz so interpolation or charts are not required.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Ultra-Thin Telemetry Collar
Advanced Telemetrics International
The Ultra-Thin Telemetry Collar houses all of the electronics needed to provide a precision radio frequency link from sensors mounted on rotating shafts to stationary data acquisition and display instruments.
-
product
110 GHz Frequency Extender
N5293AX53
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-02
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
product
Above Ground Insulator Tester / RF-IT
RF-IT
Hand Held InstrumentEasily locates shorted bolts, replaces bolt to boltUse on structure with or without CPUses Radio Frequency to test effectiveness of above ground insulatorsAuto Shut-Off feature
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX02
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
350 MHz RF Frequency Counter, 10 digits/s
53210A
Single-channel, RF frequency counter One 350 MHz input channel, plus optional second channel (6 GHz or 15 GHz)10 digits/second resolution Built-in math analysis and color, graphical display (trend and histogram)LXI-C/LAN, USB, GPIB Optional: Lithium Ion Battery BenchVue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
product
Standard 3.06 (86.70) - 4.00 (113.40) RF Probe For SMA Connectors
CSP-30ES-013
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Return Loss @ -20dB (GHz): 22.00Test Center (mil): 328Test Center (mm): 8.33Recommended Travel (mil): 100Recommended Travel (mm): 2.54Full Travel (mil): 200Full Travel (mm): 5.08Overall Length (mil): 1,033Overall Length (mm): 26.24Rec. Mounting Hole Size (mil): 297Rec. Mounting Hole Size (mm): 7.54
-
product
RF High Frequency Probes
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
product
110 GHz Frequency Extender
N5293AX03
The N5293AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
120 GHz Frequency Extender
N5295AX01
The N5295AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Maritime Navigation and Communications Antennas
LBA provides equipment and services to support shore station requirements for modern maritime communications in the low frequency, medium frequency, and high frequency radio bands
-
product
110 GHz Frequency Extender
N5293AX01
The N5293AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.





























