Frequency Meters
Meters that measure the number of cycles or events per unit time
-
Product
Automated Test Interface
ATI-100
-
Matrix Test Equipment Incorporated
Now, with our ?New? Model ATI-100 you can turn your existing Matrix Signal Generator and Switchable Filter Bank into a full-blown DTS (Distortion Test System). Plug and play is the word, just plug in your Multiple Frequency Signal Generator, Switchable Filter Bank, Spectrum Analyzer, Oscilloscope, Power Meter, Frequency Counter, etc. to allow the following automatic testing with a single insertion of DUT (device under test
-
Product
Frequency Shaped Isotropic Electric Probes
PI-SH-FCC, PI-SH-ICNIRP
-
An isotropic electric field probe with shaped frequency response meeting the ICNIRP or FCC RF safety standards for occupational and general public exposure limits (see the specified frequency ranges below). Meter readings are shown in % of the STD – standard reference level, eliminating the need to know the source frequency. Probe output is proportional to RF power density in the whole specified power range, producing the correct RF power measurements in single and multi-signal environments, typically present at multiple antenna sites.
-
Product
Field meters
-
Small, lightweight and low priced non frequency selective Efield meter. It can be used for relatively high field strengths e.g. to observe the field in a TEM cell or a strip line.
-
Product
5 Digit Frequency Meter
CS1-F
-
CS1-F economic type Frequency Meter is designed with high accuracy measurement, display and communication of Frequency.The innovation feature is auto-range input from 0.01Hz~100KHz(option ~140KHz) and the display resolution will auto-change to show the highest according to input frequency.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of panels and testing applications.
-
Product
Analog Panel Meters (W)
-
Rishabh Instruments Pvt. Ltd.,
Measure AC/DC Voltage or Current and frequency. These meters are installed on 35mm Din rail, the mounting width is 45mm and it is housed in UL 94 V-0 approved polycarbonate case and can be mounted in Mosaic mounting (cascading).
-
Product
Portable Frequency Meter
SonicSniffer
-
SonicSniffer is a portable frequency meter for preventive maintenance of ultrasonic transducers and power ultrasonic stacks, primarily in cutting and ultrasonic welding fields. The SonicSniffer determines the work frequency of the ultrasonic stack analyzing the sound emitted by the equipment during operation. See in the back side of this sheet how to use this information.
-
Product
Measurement
Frequency Meter
-
Frequency Meter is used for measuring the frequency of the signal coming to the input channels of ADC modules and FFT spectrum analyzers. The indicator displays the measured frequency value (frequency of periodic oscillations) and signal cycle time corresponding to the measured frequency. It is possible to change the averaging of the displayed value (0.1; 1, or 10 s) and to select a necessary channel of the ADC module, FFT spectrum analyzer or a virtual channel.
-
Product
P-Series Modular Power Meter (LXI Compliant)
N8262A
Power Meter
The Keysight N8262A P-Series modular power meter enables LAN-based automated measurements of peak, peak-to-average ratio and average power. The N8262A enables fast, efficient, and cost-effective creation and reconfiguration of your ATE system. Owing to LXI test standardization and its interoperability with existing test assets, your system can be up and ready in no time.
-
Product
Digital Power Meter
66205
Power Meter
The 66205 is the 2nd generation of the 66200 series power meter designed specifically for single channel measurement. Its state of art design is capable of providing highly accurate power measurements to meet the requirements of IEC 62301/EN50564 standards. Functionality improvements of the 66205 increase power measurement capabilities to a wider range of applications. The Smart Range function is one of the most important new features added to the 66205 power meter. Smart Range allows the power integration mode to perform active power measurements with the measurement range in auto mode. Chroma’s proprietary design automatically selects the appropriate range, based on changes in sensed voltage and current, ensures the best accuracy when integrating the measurements over time. The 66205 provides 10 selectable current measurement ranges from 5mA up to 30A. External sensor options A662017~A662020 are available to increase the current measurement range. Six selectable voltage ranges are available up to 600V.
-
Product
20-50 GHz Doubler
1GC1-8038
Frequency Extender
The 1GG1-8038 is a passive diode frequency doubler. It is specified to operate with a 2050 GHz output frequency. Conversion efficiency is usually around -12 dB. The device has low 1/2 and 3/2 spurious output, typically 15 dBc or better. The doubler can be biased through onchip resistors to allow operation at low input levels. Up to 22 dBm at the input can be accommodated. Onchip DC blocking capacitors are included at the input and output.
-
Product
LCR Meter 10Hz - 2 kHz High Precision
T3LCR1002
LCR Meter
LCR Meter 10Hz - 2 kHz High Precision.
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
Frequency Extender
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX02
Frequency Extender
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
110 GHz Frequency Extender
N5293AX51
Frequency Extender
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
P-Series Single Channel Power Meter
N1911A
Power Meter
30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled
-
Product
P-Series Dual Channel Power Meter
N1912A
Power Meter
30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled
-
Product
LCR Meters & Impedance Measurement Products
LCR Meter
Hewlett Packard, Agilent and Keysight have contributed innovations and product excellence in impedance analysis for over half a century. Whether your application is in R&D, production, quality assurance, or incoming inspection, we take pride in contributing to your success. We strive to deliver complete solutions to meet your needs, from impedance analyzers to a wide variety of test accessories. Achieve success with Keysight’s impedance measurement solutions.
-
Product
EPM-P Series Single Channel Power Meter
E4416A
Power Meter
The E4416A single channel EPM-P series power meter, for peak, average, peak-to-average ratio and time-gated measurements, using the E9320 peak and average power sensors.
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 100 ps
53220A
Frequency Counter
Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz)12 digits/second resolution, 100 p sec time interval resolution LXI-C/LAN, USB, GPIB Built-in math analysis and color, graphical display (trend and histogram)Optional: Lithium Ion Battery Bench Vue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
Product
K-50 Series Probes
High Frequency Probe
The K-50 coaxial probe provides an instrumentation-quality interface for broadband R.F. measurements up to 4 GHz. With the K-50 R. F. circuit design, impedance characterization measurements can be performed using it as a Network Analyzer port-extending accessory. Accurate and repeatable small signal and R.F. power (50 Watts) measurements provide consistent and repeatable results.
-
Product
100Hz/120Hz/1kHz/10kHz/100kHz Handheld LCR Meter
U1733C
LCR Meter
20,000 counts resolution0.2% accuracy Wide LCR ranges with 5 selectable test frequencies (100Hz, 120Hz and 1kHz, 10kHz and 100kHz)Auto identification(Ai) which automatically determines and displays component type and measurements Detailed component analysis with DCR, ESR, Z, D, Q, functions Battery life of 16 hours/Ac-powered IR-to-USB connectivity for data logging to PC
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
LCR Meter 10Hz - 100 kHz High Precision
T3LCR1100
LCR Meter
LCR Meter 10Hz - 100 kHz High Precision.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-01
Frequency Input Module
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
Product
Inline Optical Power Meter - MATRIQ
Power 1600 Series
Power Meter
The Power 1600 Series optical power meter provides quick and accurate inline power monitoring from -50 dBm to +20 dBm with 1, 2 or 4 channels in a compact form factor.