Non-contact Temperature
products which sense, measure and/or detect temperature.
-
product
Temperature Control Battery Short Circuit Test Chamber
Guangdong Bell Experiment Equipment Co.,Ltd
DGBELL'S Temperature control battery short circuit test chamber is designed to comply with standard. According to the short-circuit test requirement, the short-circuit must be less than 5 mΩ to achieve maximum curren.
-
product
Combined Temperature – RH probe
HP475AC1R
Relative humidity and Pt100 temperature combined probe, with SICRAM module.
-
product
Temperature, Humidity, Bar. Pressure Transmitter
T7411-4
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy. Built-in pressure sensor.
-
product
IND CAT IV TRMS Clamp Meter with Temperature
ACD-3300
This CAT IV rated ACD-3300 IND Clamp On Tester is ideal for industrial applications and utilities that require an extra level of safety. Including True-rms sensing for accuracy, this clamp on meter’s extra large jaws can clamp on to those wide diameter wires making taking measurements in industrial environments simple.
-
product
External Double Way Temperature Datalogger
VA602-TK-TJ
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
product
Walk in chamber for Complex Salt Spray Test (Temperature controllable)
Guangdong Bell Experiment Equipment Co.,Ltd
Walk in chamber for Complex Salt Spray Test Relevant standards requirement1. Test Object: battery pack andsystem.2. Refer GB/T4 part 5.5.2 test method, test according to GT/T2423.17 test conditions.3. The salt solution was made up with sodium chloride (chemically pure and analytically pure) and distilled or deionized water,Its concentration is (5 + 1)% (mass fraction).4. (35 ± 2) ℃, the measured pH value is between 6.5-7.2.5. Placed the test objects in the salt spray chamber for cycling test. Each cycling duration for 24h. Spray salt solution to the test object for 8 hours under the temperature of (35± 2) ℃ , remain for 16 hours. Between the forth and the fifth hour in one cycles should be according to test requirement in GB/T 28046.1-2011, test mode with 3.2.6. Total 6 cycles testing.7. Salt spray test is not necessary for the test objects being installed in passenger, luggage or cargo compartments.
-
product
Temperature Data Acquisition
THERMES-USB
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
product
2MP Wide Temperature Range Industrial Grade HDR Camera
E-CAM20_CU0230_MOD
e-CAM20_CU0230_MOD is a 2MP high performance, HDR Camera Module with excellent low light performance. It is based on AR0230AT CMOS Image sensor from ON Semiconductor®. It has an ability to stream seamlessly at wide temperature range (-40 to 105°C) which is suitable for Automotive application. It has S-mount (M12) lens holder which allows customers to choose and use the lens according to their requirement.
-
product
Temperature, Humidity, Bar. Pressure Transmitter
T7310
Built-in relative humidity, temperature, atmospheric pressure sensors. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Data Logger Temperature Humidity
VAT810-TH/SD (VAT810-CO2)
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Desktop:Touch buttons : CO2 monitor Real-time monitoring of indoor air quality including CO2,temperature ,humudity and VOC.
-
product
MCB Temperature Rise and Power Loss Test Bench
The SCR Elektroniks 3 station MCB Temperature Rise and Power Loss Test Bench is economically designed to verify temperature rise and measure power loss as per clause 9.8 of IEC 60898 with the circuit designed to follow test procedure as per Cl 9.8.2. The temperature rise is measured in accordance with Cl 9.8.3 and 9.8.4 while power loss is measured and verified as per Table 15 of Cl 9.8.5.
-
product
Temperature Indicator
Aarohi Embedded Systems Pvt. Ltd
Aarohi develop special temperature indicator for motor & pump testing with high accuracy. Micro controller based design provide fast response, precise measurement & easy compatibility with data acquisition system
-
product
High Temperature VSM probe
To perform measurements at or above room temperature, separate heated sample probes are offered for electrical or magnetic measurements. In normal operation, the CFMS has a continuous temperature range of 1.6 K to 400 K. With these inserts the range can be extended up to 1000 K.
-
product
Temperature and Humidity Duct Probe
T0213
Relative humidity, temperature sensors at 150mm stem. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Temperature, Humidity, CO2 Transmitter
T6340
The transmitters are designed for online measurement of temperature (C or F), relative humidity and carbon dioxide concentration of air without aggressive ingredients. Measured temperature andrelative humidity are recomputed to following humidity expression: dew point temperature, absolutehumidity, specific humidity, mixing ratio and specific enthalpy.
-
product
High & Low Temperature Impact System for ATF Cooling Motor
EVTP-30
Shanghai Dean Electrical Co., Ltd
This test system provides the most direct life evaluation of ATF cooling based EV motor by simulating the temperature impact from ultimate self- heating of the motor and severe cold condition from environment.
-
product
Temperature and Humidity Transmitter
T3419
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Humidity and Temperature Transmitter
T3111Ex-4
Relative humidity, temperature sensors at probe on the cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
product
Bluetooth® Enabled ORP/REDOX & Temperature Pen
UltrapenX2™ PTBT3
*Accuracy of ± 10 mV ORP*3 Calibration Options with Automatic Solution Recognition*Automatic Temperature Compensation in Calibration Mode*99.9% Pure Platinum Electrode*Measurement Storage with Time, Date and Location*Export Stored Measurement Data Via Email*Live or Hold Mode – User Selectable*Proprietary Sensor Design*Rugged Design with Aircraft Aluminum Body*Durable, Epoxy Encapsulated Electronics*Powered by One N Type Battery (Included)*Waterproof
-
product
Non-contact Sheet Resistance /resistivity Measurement Instrument
EC-80
*Easy operation and compact design*Auto-measurement start by inserting a wafer under the probe*Easy set up to measurement condition by JOG dial*5 types of model for each measuring range
-
product
Round Handle Style Temperature Sensors
A comprehensive selection of round handle hand held temperature sensors to suit a wide range of applications. 14 varieties to choose from.
-
product
Temperature Dependent Lifetime Measurement
WCT-120TS
Wafer lifetime measurement instrument Offering calibrated analysis of temperature-dependent carrier-recombination lifetime.
-
product
Temperature Switches
Analog Devices trip point temperature switches monitor temperature and activate digital output when measurements exceed the trip point setting. To meet differing design needs, we provide pin selectable, factory set, and user programmable trip point setting options. With support for a wide range of operating temperatures and without the need for external calibration, our portfolio of temperature switches also enable swifter design and production with faster time to market.
-
product
Logger and Handheld Instruments for Temperature Measurement and Monitoring
Temperature measurement and monitoring is vital for the quality of temperature-sensitive products wherever they are studied, produced, stored or transported.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Temperature Logger
SRIC-4
The LogTag® SRIC-4 is a single-trip temperature logger developed specifically for monitoring temperature sensitive products in both short haul and long-distance transportation applications. The SRIC-4 combines all the features of an advanced temperature logger with a 3968 log memory and a 6-month operating life in a robust and inexpensive package.
-
product
Temperature Loop Control Setup
ULP-27
Unitech Scales And Measurements Pvt. Ltd
Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.
-
product
Oven Temperature Profile
Temperature profiling provides an effective method for measuring the actual environmental and product temperature during the cure process - essential for ensuring quality finish and a successful cure of a powder coating.
-
product
1000 A AC/DC Navigator Clamp Meter with Temperature
Amprobe ACDC-54NAV
The ACDC-54NAV clamp-on power meter offers AC/DC current measurements to 1000 A, AC/DC voltage to 1000 V, temperature capabilities, and wide jaws to handle large conductors up to 1.6″ (40 mm) for high voltage industrial environments.





























