ITA Modules
-
product
Signal, Module, ID, CASS, 64 Position, Discrete Wiring
510114108
Signal, Module, ID, CASS, 64 Position, Discrete Wiring.
-
product
Signal / High Power, Module, ITA, TriPaddle, 90 Series, 6/6 Positions
510108281
Primary mating module 510104307.
-
product
Digital to LVDT Converters
ST-DLVA
Computer Conversions Corporation
The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices.
-
product
Signal, Contact, ITA, TriPaddle, 7 Amp, 26-28 AWG
610110169
Primary mating contact 610110167. (May mate with other Receiver contacts, as well.)Specifications Operating Voltage & Current 7 Amps Max. Continuous (20 AWG)Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 4000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
ITA, ICon XL, 2 Module, Extra-Large Backshell, EMI
410123232
The iCon XL offers an extra-large u-shaped cable clamp that can hold cable bundles with an oblong bushing effective diameter of 1.95" and offers a cable bend radius of 1". A slide-off backshell allows easy access to wiring for maintenance and probing. The iCon XL also offers EMI shielding.
-
product
Signal, Contact, ITA, TriPaddle, 10 Amp, 14-18 AWG
610110129
Primary mating contact 610110128. (May mate with other Receiver contacts, as well.)Specifications Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)600 Volt Max. use of wire Mil-W-16878/4Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs.) 0.41
-
product
LVDT to Digital and RVDT to Digital Converters
Computer Conversions Corporation
LVDT Displacement transducers accurately measure position and displacement. The strength of the LVDT is in its principle of operation. As LVDT sensors are inductive, there is no electrical connection across the sensor, which ensures clean, accurate data and a long life.
-
product
ITA, G10x, 15 Module
410104818
This version of the G10x ITA comes without a removable backshell or clamps. Due to the extra module positions, the G10x ITAs are only compatible with G10x receivers.
-
product
ITA, 9050, 50 Module, Double Tier, EMI, with 8" Enclosure
410104580
This 9050 ITA comes with an 8" enclosure for ease of system integration. The ITA is designed to work with the 9050 EMI receiver.
-
product
ITA, i2 MX, EMI Backshell, with Cable Exit (Shell only, does not include front protective cover or modules)
410130114
ITA, i2 MX, EMI Backshell, with Cable Exit (Shell only, does not include front protective cover or modules)
-
product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, .025" Square Post for Wire Wrap with Anti-Rotation
610138122
Primary mating contact 610138200. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
ITA, IDock Series, D1, 1 Module
410131102
ITA, iDock Series, D1, 1 Module The D1 ITA can engage up to 160 signal contacts. Select any of our iCon series modules to configure your D1's I/O.
-
product
Signal/Thermocouple, Module, ITA, TriPaddle , 90 Series, 84/12 Position
510108245
Primary mating module 510104261.
-
product
ID, CASS, 19 Module, Single Tier, Commercial
410113105
ID, CASS, 19 Module, Single Tier, Commercial.
-
product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, .025" Round Post
610138115
Primary mating contact 610138200. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body (RCV) – BeCu (Twin Female)BeCu/PhBrz (Crimp)Male (ITA) – BrassContact Plating Female (RCV) – 50µ” Au over 100µ” NiMale (ITA) – 30µ” Au over 100µ” NiCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
product
PXI Carrier Module For SwitchBlock
The PXI Carrier Module for SwitchBlock can hold up to six Matrix Modules for SwitchBlock while occupying four PXI slots. By connecting multiple SwitchBlock relay cards through the carrier's integrated analog bus, you can easily create large matrices with more than 2,000 crosspoints in four PXI slots and more than 8,000 crosspoints in a single PXI chassis. Each Matrix Module for SwitchBlock comes in an A-type version, which serves as the first matrix building block and offers row and column access through the front connector, and a B-type version, which serves as an expansion module and only provides column access through the front connector. Typically, SwitchBlock systems contain one A-type module and numerous B-type modules.
-
product
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position
510144006
Signal, Module Insert, ITA, i2 MX, TriPaddle ,33 Position.
-
product
PXI FlexRIO Coprocessor Module
PXI FlexRIO Coprocessor Modules feature high-performance FPGAs that add signal processing capability to PXI systems. These modules leverage the latest FPGAs from Xilinx, streaming technologies such as PCI Express, and NI Peer to Peer Streaming for high-bandwidth data communication with other modules over the backplane. When paired with another PXI device, such as a PXI Vector Signal Transceiver, PXI FlexRIO Coprocessor Modules provide the additional FPGA resources required to run complex algorithms in real-time.
-
product
LabVIEW Tools for Digital Filter Design and Implementation
LabVIEW Digital Filter Design Toolkit
The LabVIEW Digital Filter Design Toolkit extends LabVIEW with functions and interactive tools for the design, analysis, and implementation of digital filters. New digital filter users can explore classical designs with the built-in interactive design tools, while experienced users can find a breadth of algorithms, filter topologies, and analysis tools for both fixed- and floating-point digital filters. For fixed-point filters, you can model quantization effects, optimize numeric representation/topology, and deploy the design on a digital signal processor or FPGA using automatically generated ANSI C or LabVIEW FPGA code.
-
product
ITA, iCon, Extended Cable Clamp
410123115
This iCon ITA includes an extended cable clamp to accommodate larger cable bundles. The maximum cable bundle area = 1.97 " sq. or a 1.58"/40.13mm diameter bundle. The clamp may be inverted for smaller cable bundles.Please note: This ITA does not offer an increased bend radius that may occur with a larger cable bundle radius. Larger bend radius is offered by the iCon XL, p/n 410123232.
-
product
PXI GPIB Instrument Control Module
PXI GPIB Instrument Control Modules feature IEEE 488 controllers for PXI systems. You can choose an option that supports Gigabit Ethernet transfer speeds. PXI GPIB Instrument Control Modules include a license for the industry standard NI-488.2 driver software enabling reliable connections to third-party instruments with GPIB.
-
product
ITA, G6x, 9 Module, Removable Backshell, Keying Feature
410104769
The adaptable G6x ITA integrates a wide variety of I/O options in various module configurations that allow engagement of up to 1,920 signal contacts. The G6x ITA has a removable backshell that also reduces electromagnetic interference.
-
product
Digital to LVDT-Digital to RVDT Converters
Computer Conversions Corporation
The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices.
-
product
PXI 8 Slot BRIC 88x8 2-pole (4 sub-cards)
40-562A-122-88X8
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
product
PXI Single 32x8 Matrix, 1 Pole Switching
40-531-021
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 6 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-002-E
The 40-784B-002-E (PXI) and 42-784B-002-E (PXIe) are dual failsafe SP6T 6 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI 9 x SPDT RF Switch 500MHz 50 Multiway Connectors
40-754-009
The 40-754 is a 50Ω High Density RF switch available with 17 or 9 SPDT relays in a single PXI module. The 40-754 is available with two connector options; an SMB connector that provides a frequency range of 1.2GHz (useable to 1.8GHz) occupying two PXI slots, or an MS-M RF multiway connector which limits the bandwidth to 500MHz but offers a high density solution occupying one PXI slot. The RF switch design is identical in each case.
-
product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Failsafe
42-788-121
The 40-788-121 (PXI) and 42-788-121 (PXIe) are single failsafe SP10T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.