Filter Results By:
Products
Applications
Manufacturers
-
product
LXI Microwave Matrix, 12x12, 50Ω, 18GHz
60-891-007
The 60-891-007 is a compact 50 Ω microwave switching matrix with a maximum bandwidth of 18 GHz. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance rear panel mounted N-type connectors.
-
product
LXI Microwave Multiplexer, 50Ω 6-Channel 8-Bank 26.5GHz SMA
60-801-308
The 60-801-308 is a 6-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Reed Relay Matrix - Single 64x8 Plugin, No Direct Y Access, 6 Analog Buses
65-223-102
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 8-Bank 40GHz SMA-2.9
60-802-408
The 60-802-408 is a 4-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Reed Relay Matrix - Dual 128x4 Plugin, No Direct Y Access, 6 Analog Buses
65-221-111
The range includes four plug-in models covering matrices of up to 1,536x4 in increments of 128 (model 65-221), 768x8 in increments of 64 (model 65-223), 384x16 in increments of 32 (model 65-225), and 192x32 in increments of 32 (model 65-227). Users can specify as many or as few plug-in modules (up to six) required and can field upgrade the chassis to extend the matrix when necessary. Another important feature is that over 1,500 relays can be closed simultaneously for specific conditions for parametric testing.
-
product
LXI 2.4GHz 50ohm 32x8 Matrix
60-771-001
The 60-771 is a family of integrated RF matrices suitable for use up to 2.4GHz in a 50 ohm transmission line system. The matrix design permits any single Y input to be connected to any single X input, permitting the concurrent connection of 8 RF paths. All signal paths are bi-directional permitting any connection to be used as an input or an output.
-
product
LXI Microwave Multiplexer, SP6T, 9-Bank, 18GHz, 50Ω, SMA
60-800-109
Our 60-800-109 is a 9 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
Diagnostic Test Tool
BIRST™ (Built-In Relay Self-Test)
Verification and diagnosis of complex switching operation in a test system has always been an issue. BIRST (Built-In-Relay-Self-Test) diagnostic test tool provides a quick and simple way of finding relay failures available on some of our LXI and PXI switch matrices.
-
product
DC System Power Supply, 600 V, 1.3 A, 780 W
N5752A
The single output, 780 W N5752A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 14-Bank 18GHz SMA
60-802-214
The 60-802-214 is a 4-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI Microwave Matrix, 10GHz, Dual 3x3
60-750-233
The 60-750-233 is a dual 3x3 10GHz microwave matrix. It is part of the 60-750/751 range of LXI Microwave Switches controlled through an LXI compliant Ethernet connection. It is available in a variety of configurations and frequencies up to 18GHz (60-751). The matrix is characterized for 50 ohm applications, for 75 ohm versions please consult your local sales representative.
-
product
LXI 16:1 Optical MUX FC Loop-Thru
60-850-423
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.
-
product
LXI Single 24x8 HF Matrix, BNC (75R)
60-711-005
The 60-711 is a Dual 24x8 Video Matrix Module suitable for switching frequencies up to 25MHz. It has a characteristic impedance of 75 Ohm with the option of SMB or MCX connectors or, with a larger case size, BNC connectors. It is designed to provide a simple and scalable bidirectional matrix for video frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems. Software configuration allows the 60-711 to be set as a dual 24 by 8 matrix, a single 48 by 8 matrix and other configurations.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 4-Bank 18GHz SMA
60-802-204
The 60-802-204 is a 4-channel, 4-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI High Density 56x64 2A Matrix With BIRST
60-552-026
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
product
LXI High Density 320x4 Matrix - 60-551-025
60-551-025
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
product
LXI Microwave Multiplexer, SP6T, 10-Bank, 67GHz, 50Ω, SMA-1.85
60-800-810
Our 60-800-810 is a 10 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 5-Bank 18GHz SMA
60-802-205
The 60-802-205 is a 4-channel, 5-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
Electronic DC Load, 500V, 16A, 400W
LDH400 Series
Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option
-
product
50 Ohm MMCX to MMCX Cable Assembly
40-977-571-0.5m
This 0.5m long MMCX cable assembly is part of the range of RF cables. Pickering Interfaces offer a range of RF cable assemblies to complement our extensive range of PXI, LXI, PCI, VXI and GPIB switching products. All cable assemblies are made from high quality materials and use best practice assembly methods to ensure the cabling matches the performance of the switching modules they support.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 14-Bank 26.5GHz SMA
60-802-314
The 60-802-314 is a 4-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
LXI-Certified 1.85mm Automated Tuners 8.0 to 65.0 GHz
MT985 Series
Maury''s MT985AL01 LXI controlled automated tuners are optimized for a broad class of in-fixture and on-wafer applications requiring flexibility, broad frequency coverage and ease of use. Based on Maury''s proven non-contacting probe technology, these high-performance tuners evolve beyond outdated contacting probe technology to deliver high VSWR with superb accuracy and reliability.
-
product
Chassis Mounting Kit For 40-922 & 60-102
63-102-001
This chassis mounting kit is designed for use with the our 8-slot PXI chassis (40-922) and our 7-slot LXI modular switching chassis (60-102), allowing installation into a standard 19" rack. The frame increases the overall height to 5U and allows space for cooling air to be drawn into the underside and expelled from the top of the chassis
-
product
Precision DC Power Module, 20V, 50A, 500W
N6765A
The Keysight N6765A is a 500 W precision DC power module that provides low noise, and precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB and LXI compliance are standard. Select from more than 30 different DC power modules ranging in capability from basic to high precision, and in power from 20-500 Watts.
-
product
LXI WTB Probe, Thru connect, DC coupled
60-981-001
The 60-981 LXI Wired Trigger Probe provides a simple method of monitoring the LXI Wired Trigger Bus activity. It provides a through line active probe that can be used to non-intrusively monitor the waveforms of the M-LVDS drivers on all 8 channels. Each channel has two single ended outputs from the differential pair that can be subtracted by an oscilloscope to display each driver output and the differential signal.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 3-Bank 40GHz SMA-2.9
60-802-403
The 60-802-403 is a 4-channel, 3-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
DC Power Module, 100V, 1A, 100W
N6746B
This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB, and LXI compliance are standard. Select from more than 20 different DC power modules, ranging in capability from basic to high precision, and in power from 20 - 300 W.
-
product
LXI RF & Microwave Matrices
Each of our RF & Microwave matrices is designed to have a controlled transmission line impedance and architecture developed to maximize the bandwidth of the product. The RF matrices are designed with crosspoint switch systems interlinked with isolation relays and loop-thru connections to minimize stub loading of the matrix. The mechanical and electrical freedom of LXI allows us to design RF and Microwave matrices to suit most applications.
-
product
LXI High-density 384x4, 2A Matrix
60-553-003
These high-density single pole LXI matrix modules are capable of switching up to 150VDC/100VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
product
LXI Single 32 Channel Fiber Multiplexer FC/APC, Single-Mode
60-850-014
The 60-850 and 60-851 are LXI conformant fiber optic multiplexers that use MEMS switching technology to ensure fast and reliable switching of single-mode (60-850) or multi-mode (60-851) optical signals being carried on fiber connections. The 60-850/851 is available with a variety of connector options and in a variety of multiplexer arrangements. Loop-thru versions are also available for easy multiplexer expansion.