Preamplifiers
Detect and strengthen a signal prior to greater amplification.
See Also: Amplifiers, RF Amplifiers, Current Amplifiers, Audio Amplifiers, Voltage Amplifiers, Transconductance Amplifiers, Op Amps, Klystron, Instrumentation Amplifiers, Distribution Amplifiers
-
Product
Preamplifiers
-
A.H. Systems'' Preamplifier line is an excellent choice with a rugged design, no hassles with soldering your own power leads and they improve overall system sensitivity by at least 20 dB. All of A.H. Systems'' Preamplifiers come with a 12-volt (or 15-volt) DC regulated power source. A low voltage indicator confidently allows you to power the amplifier with your own external 12-volt DC battery. This makes it a convenient choice for field measurements. See table below for amplifier specifications.
-
Product
Preamplifiers
AH-series
-
A broad mix of in-line preamplifiers and accessories are offered to enhance hydrophone measurements by increasing the gain, preserving the flatness response, extending the dynamic range, and minimizing reflections.
-
Product
Preamplifiers
LNA Series
-
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
Product
Preamplifiers
-
Is an electronic amplifier that converts a weak electrical signal into an output signal strong enough to be noise-tolerant and strong enough for further processing, or for sending to a power amplifier and a loudspeaker.
-
Product
DryLoc pH/ORP Preamplifier and Connectors
2760
-
The 2760 preamplifier allows any DryLoc pH/ORP electrode to work with Signet ProcessPro and ProPoint pH/ORP instruments. It is also sold as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal.
-
Product
ProBus Probe Adapter for TekProbe-BNC Probes
TPA10
-
- Allows TekProbe interface level II probes to work with any ProBus-equipped Teledyne LeCroy oscilloscope- Automatic probe detection- Provides all necessary power and offset control to the attached probe- Supports probes up to 4 GHz- Easy firmware updates- Wide variety of probes supported including: Preamplifiers, Current Probes, Single-Ended Active Probes and Differential Active Probes
-
Product
Active broadband antenna up to 6GHz
Series HyperLOG ® 70 X
-
Compatible with any Spectrum Analyzer or Oscilloscope. Incl. High-End Preamplifier. Ultra high gain (44dBi). The HyperLOG X LogPer antenna series can be used to locate extremely weak signals, thanks to the integrated preamplifier. The antenna offers excellent directional characteristics which can be optimized using theoptional Laser and Compass.
-
Product
Low Noise Prepolarized Microphone
378A04
-
The 378A04 is a matched system that is comprised of a high sensitivity microphone and a low noise preamplifier that contains a built-in filter that enables the free-field response to remain flat over a wide frequency range. The system requires a minimum of 4 mA and measures to 6.5 dBA (5.5 dBA typical) within a cost efficient, prepolarized (0V) design. PCB's model 378A04, the industry's first prepolarized low noise microphone and preamplifier system allows you to measure extremely low amplitudes. In the past this was only possible with externally polarized solutions. With a typical noise floor of 5.5dBA, this microphone system delivers all of the benefits commonly associated with prepolarized systems.
-
Product
16 Channel USB Sensor Interface
RogaDAQ16
-
With the introduction of the RogaDAQ16 USB 2.0 data acquisition system, a new age of measurement technology begins.*USB 2.0 / 480MBIT (USB1.1/12MBIT COMPATIBLE)*16 analog input channels (16bit/500kHz max.)*ICP ® ( IEPE ) sensor supply (24V/4mA)*0.125V to 10V input range*Individual preamplifiers*4 analog output channels (16bit/100kHz)*Powerful DSP (255MIPS) for filtering, control etc.*24 digital I/Os*Optional 24bit counter, timer, PWM, incremental encoder*Free drivers for major application software*including DASYLab; LabView & DiaDem drivers & RogaRec Software
-
Product
Preamplifier
-
Is designed for the amplification of measuring signals, e.g. weak signals of near field probes with high resolution.
-
Product
Noise Figure Analysis Using NI PXI RF Test Instruments
NI-RFmx Noise Figure
Test Instrument
Measure noise figure, gain, Y-factor, effective temperatures, hot and cold power, and moreOptimized calibration and measurement routines for multi-DUT test using Y-factor and cold sourceSupports the PXIe-5668R 26.5 GHz VSA, the PXIe-5698 26.5 GHz preamplifier, and VSTsDesigned for use with industry-standard noise sources such as the Noisecom NC346 Series
-
Product
Power Probes
RkP-400 Series
-
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
Product
C-Band Single Channel Pre-Amplifier EDFA (SPA)
HSA4300 (With SNMP)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HSA4300 series is a low noise pre-EDFA which designed specifically for single wavelength optic transmission system. It is installed in the front of optical receiver, used for improving the receiving sensitivity of the optical receiver, and extending the signal transmission distance.
-
Product
C-Band DWDM Pre-Amplifier EDFA (WPA-C)
HWA4300 (With SNMP)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HWA4300 series, is designed for C-Band 44 waves or 88 waves DWDM system design Pre-Amplifier gain flatness. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, Low noise, excellent gain flatness characteristics and transient characteristics.
-
Product
Miniature AE Sensor With Isolated Integral 30 DB
-
The Guzik miniature AE sensor with isolated integral 30 dB preamplifier has a wide-band and excellent frequency response over the range of up-to 1 MHz. Its small size makes the sensor ideal for hard disk drive test or similar applications requiring very small size, low weight, wideband AE sensor response and high sensitivity. A small diameter, external flexible cable connects the sensor with a 3-pin JST connector on the other end.
-
Product
Noise Figure Analyzer, Multi-touch, 10 MHz to 40 GHz
N8976B
Low-Frequency Noise Analyzer
The N8976B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8976B.
-
Product
(100×130×19mm) C-Band DWDM Pre-Amplifier EDFA Module
WPA4300-FM04
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai WPA4300-FM04 series with 100 × 130 × 19mm Compact package, is a digital control circuit with DWDM full function preamplifier module. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, low noise, excellent gain flatness characteristics and transient characteristics. Suitable for C-Band 44 or 88 wave wave DWDM system applications.
-
Product
Current Preamplifier
1211
-
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
Product
(70×90×15mm) Full Function Single Channel MSA Compact Pre-Amplifier EDFA Module
SPA4300-FM02
-
Hangzhou Huatai Optic Tech. Co., Ltd.
SPA4300-FM02 is a full-function optical Pre-Amplifier with digital control electronics, adopts 70×90×15mm MSA compact package. It is featured with high reliability, superior optical performance and compact reasonable configuration by Industrial standard, creating the most flexible and variable low-cost amplifier in the market. This module is suitable for multiple network application, especially the application that requires 40GB/S transmission speed.
-
Product
Acoustic Emission Preamplifier
-
The Acoustic Emission Preamplifier is a instrument designed specifically for use with acoustic emission sensors, which is used to boost the signals and filter out any noise or interference. With its advanced technical features and robust design, the QingCheng Acoustic Emission Preamplifier is the perfect choice for professionals seeking a high-performance acoustic testing solution.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Microphone System
378B02
-
This model includes a 1/2" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Microphone Preamplifier
426B31
-
Performance:Nominal Microphone Diameter:1/4" Frequency Response:3.98 to 126000 Hz3.98 to 126000 10.0 to 126000 Hz10.0 to 126000 HzElectrical Noise (A-weight)3.8 TEDS CompliantYes
-
Product
FieldFox Handheld Microwave Spectrum Analyzer, 26.5 GHz
N9938B
Spectrum Analyzer
A lightweight, durable, microwave spectrum analyzer, interference analyzer, distance-tracking generator, preamplifier, power meter, and more.
-
Product
Signal Processor Board
MS 1532
-
- Frequency coverage from 5 kHz to 30 MHz in 1-Hz steps- High dynamic range: +30 dBm 3rd-order intercept typical- Digital filtering provides 58 IFBWs from 56 Hz to 8.0 kHz with exceptional shape factors- AM, Synchronous AM, FM, CW, USB, LSB & ISB detection modes standard- Tunable notch filter- Fast, flexible scanning with 100 memory channels- Large readable LED displays & user-friendly controls- Noise blanking & pass band tuning- Internal switchable preamplifier & attenuator- Operator-selectable RS-232, RS-485, or- RS-422 remote control- Viretx 5 FPGA based design (Two virtex for image processing)- LPC2468 ARM 7 Processor based design- MIL1553B and RS485 Interface- Two High speed 14 bit ADC (125MSPS) for I & Q Sampling- Direct sampling 2-30MHz- Audio CODEC- Conduction Cooled Board
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
Low Noise Differential Preamplifiers
-
Provide a high gain amplification to 1MHz with an AC output derived from a very low noise FET instrumentation amplifier. Each model has fixed gain settings of x1 (0dB), x10 (20dB), x100 (40dB) and x1000 (60dB) over a selectable bandwidths of 100Hz, 1kHz (HP), 3kHz, 30kHz, 100kHz and 1MHz (7000 model only). Noise referred to input is 7nV√Hz and common mode rejection is >100dB at 1kHz. Momentary pushbutton switches are provided that control coupling, bandwidth, gain and channel on/off selections. BNC connectors are provided for single-ended and differential input, ac output, and dc output (optional) connections.
-
Product
Active Input Module for Teledyne RESON TC4014 and TC4032, Hydrophones with Built-In Preamplifiers
EC6076
-
The EC6076 Active Input module is for the Teledyne RESON TC4014 and TC4032 hydrophones with built-in pre-amplifiers.EC6076 provides an easy interface to the hydrophones, it al-lows use of the differential output from the hydrophones ei-ther via direct feedthrough of the signal on an XLR output con-nector or via the built-in differential amplifier that converts the differential hydrophone signal into a single-ended +6dB signal on a BNC/coax out. EC6076 has a built-in rechargeable battery that provides power for the EC6076 differential amplifier and the TC4000 hydrophone.
-
Product
(70×90×15mm) C-Band DWDM Full Function Pre EDFA Module
WPA4300-FM02
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai Huatai WPA4300-FM02 series with 70 × 90 × 15mm MSA compact package, is a digital control circuit with DWDM full function preamplifier module. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, low noise, excellent gain flatness characteristics and transient characteristics. Suitable for C-Band 44 or 88 waves DWDM system applications.
-
Product
Programmable Current Preamplifier
99539
-
The Model 99539 is a modular, multi-channel current preamplifier with parallel, logic level, gain control input. It consists of circuit boards which plug into a 3 1/2" high by 19" wide rack chassis.





























