-
product
Frequency Counters
Frequency Counters measure frequency, period, time interval, pulse width, duty cycle, frequency ratio, phase, and more. Frequency counter products include options that are compatible with Astronics/Racal VXI-2461C, which can be used for automated test aerospace and defense applications.
-
product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX52
The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
120 GHz Frequency Extender
N5295AX03
The N5295AX03 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
120 GHz Frequency Extender
N5295AX53
The N5295AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40L-013
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
110 GHz Frequency Extender
N5293AX51
The N5293AX51 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 100 ps
53220A
Two 350 MHz input channels, plus optional third channel (6 GHz or 15 GHz)12 digits/second resolution, 100 p sec time interval resolution LXI-C/LAN, USB, GPIB Built-in math analysis and color, graphical display (trend and histogram)Optional: Lithium Ion Battery Bench Vue software enabled: Do more with your PC and instrument together, no programming required. Easily control your counters, quickly build automated tests and log data for faster analysis and save precious time.
-
product
350 MHz Universal Frequency Counter/Timer, 12 digits/s, 20 ps
53230A
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
Your product description goes here.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Frequency Reference
Quartzlock time and frequency standards offer a complete range of cost effective and low noise in both atomic controlled (rubidium oscillator) and GPS controlled (off-air) time and frequency reference, calibrators and standards. These acurate time and frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
product
Frequency Multipliers
RF coaxial frequency multiplier (also referred to as a coaxial frequency doubler) PE8600 from Pasternack has SMA conectors and are 50 Ohm. Our SMA frequency multiplier is manufactured for a minimum frequency input of 1.5 GHz and a maximum frequency input of 5 GHz. This SMA microwave frequency multiplier / doubler output minimum frequency is 3 GHz and output maximum frequency of 10 GHz.
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Frequency Analyzers
The groundbreaking multi function measuring system from RION Compact design, easy and intuitive operation Wireless connections Use it anytime anywhere!
-
product
Frequency Counters
Combines a calibrated RMS RF Power Meter, a wide-band frequency counter, and a RF Signal Generator into one miniature USB device. Incredibly useful in production verification environments and other automated test setups.
-
product
Frequency Large Display Indicator
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
product
High Frequency Modules
Digital Signal Technology, Inc.
Modulators, frequency dividers, amplifiers, filters, etc.
-
product
Frequency Meters
Passive frequency meters are intended for moderate (±0.05%) accuracy applications in microwave measuring setups. Keysight's meters feature broadband coupling loops that provide flat power transmission off-frequency.
-
product
Frequency Converters
Analytic Systems' Single and 3-Phase Sine-Wave Converters deliver output power ranging from 250 VA to 5000 VA. Our Frequency Converters also generate nominal output voltages of 115 VAC or 220 VAC, at frequencies of 50, 60 or 400 Hz. A broad range of input voltages are available.
-
product
Frequency Dividers
Holzworth Instrumentation, Inc.
The HX4210 was designed as a reference output translator for Holzworth's early RF Synthesizer designs. The key design requirement was to maintain the low phase noise /jitter characteristics the 100MHz calibrated reference output signal so that it could be utilized as a 10MHz laboratory reference standard.
-
product
Frequency Discriminators & IFM
PMI offers a full line of RF and Microwave frequency discriminator products that range from a few MHz up to 18.0 GHz. Many options are available. If you do not see exactly what you need, please e-mail your requirement to sales@pmi-rf.com so we can propose an instant solution.
-
product
Time & Frequency Standards
Meridian II Precision TimeBase
The Meridian II Precision TimeBase is a modular, network-centric, time & frequency standard that provides the most precise and stable, GPS-synchronized, time & frequency outputs in the world. Unlike our competitors, we fully specify the performance of Meridian II and back it up with published data measured at NIST.
-
product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
product
Neodymium Low Frequency Transducers
High energy neodymium magnetic designs, complex cooling systems and new technologies for high-power handling, minimal distortion and low weight.
-
product
High Frequency Surge Testers
The 50KV Digital P J High Frequency Surge Tester is the most powerful tester in a class of its own. No other 50KV Surge Tester can pulse/resonate 60 pulses per second at a risetime of 100 nano seconds.This powerhouse is loaded with the TDS3012B Digital Phosphor colored oscilloscope with a built-in floppy disk drive.





























