Radiation
The transmission of energy through material or space.
-
Product
Sola-Sure System
-
Health & Safety solution to support the industries where dangers may exist of UV lamp radiation coming into contact with human skin. Increasingly driven by national and government regulations the Sola-Sure identifies higher energy radiation that can cause damage to humans in solarium, medical treatment and the industrial UV work place.
-
Product
Orotron (High-Power BWO) Based Sources 120 To 370 GHz
-
Insight Product Company offers Orotron based sources of radiation at frequencies 120 to 370 GHz. The Oroton tube is installed inside the permanent magnet and does not require any adjustment by the customer. The Orotron sources are wide-banded, small in size, very reliable, powerful, and easy to operate. We offer phase-locking as an option on our Orotron based sources to maximize the phase and frequency stability.
-
Product
Electronic Inspection Systems
-
Intego's knowhow even makes it possible to identify challenging defects that may be located under the surface. One system is the inspection of chips by means of lock-in thermography, which visually represents the IR radiation intensity signal of electronics. Special lasers and flash lamps generate a very short heat impulse (10 ms) on the chip, which generates a measurable heat flow. In most cases, a resolution of < 1 μm can be achieved.
-
Product
USB 2.0 Interface Module
-
USB 2.0 modules for RF Test Enclosures eliminate conducted and radiated interference while keeping data and power signals for the USB 2.0 link untouched.
-
Product
Eddy Current Probes and Drivers
-
Proximity sensors work on the eddy current principle. A proximity system consists of an eddy current probe, extension cable and driver. A high-frequency RF signal is generated by the driver, sent through the extension and probe cables and radiated from the probe tip. The tip consists of a precision wound copper coil inside a chemical and temperature resistant PEEK case.
-
Product
Infrared-Thermometer
-
Is a thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
Product
Geiger Counters
-
A geiger counter detects nuclear radiation by measuring the emission of ionizing radiation of alpha particles, beta particles and gamma rays. Also referred to as a radiation detector, a geiger counter consists of two main elements: the processing electronics and the geiger tube. The geiger tube is filled with low-pressure inert gas like helium, argon or neon. If radioactive radiation occurs, the inert gas is ionized. An anode within the geiger tube registers the quantity of ionized particles numerically correlating with the strength of the radioactive radiation. The radioactivity measurement is then displayed on the LCD screen of the geiger counter or radiation detector.It is very important to measure radioactivity as well as to classify radioactivity values. For example, terrestrial gamma radiation is measured according to general values from 0.03 - 0.3 µSv/h (microsievert / hour). This "normal" oscillation range is conditioned by natural radioactive elements in the ground such as uranium and potassium. To calculate this factor, one must take into consideration cosmic radiation. For example, when considering cosmic radiation, the maximum radioactivity content at Schneefernerhaus, the highest-located German environmental research station, is approximately equal to 110 µSv/h.At PCE Instruments, you will find three types of geiger counter or raditation detection devices to help you measure radioactivity: 1) alpha radioactivity meters, 2) meters for detecting alpha, beta and gamma radioactivity and 3) radioactivity meters for human beings.
-
Product
Battery Chargers
-
DC Battery ChargersStep-Up & Step-Down DC Source Chargers and Equalizers These units provide up to 600 watts to charge a 12V or 24 V battery systems (1 or 2 banks) from a 12, 24, 32 or 36 volt source. The single-board design incorporates state-of-the-art switch mode technology for unmatched efficiency and ultra-quiet operation. Multiple stages of filtering reduce radiated or conducted noise to very low levels. All Series are capable of charging up to two independent banks of batteries.
-
Product
Radiometers For Laser Radiation
-
Laser Power Meters, Radiometers, Dosimeters and Data Loggers for Irradiance, Laser Power, Laser Energy and Pulse Shape in the 400 nm - 1800 nm Wavelength Range.
-
Product
HIRF Testing
-
High Intensity Radiated Fields (HIRF) testing simulates high RF peak pulsed and average fields typical of radar environments and is integral to the certification of flight essential avionics systems. L3 Cincinnati Electronics (L3 CE) can perform HIRF testing from 400 MHz to 18 GHz (with traditional average field testing from 10 kHz to 40 GHz).
-
Product
Radiator Mounted Load Banks
RD-Series
-
RD-series radiator mounted load banks are designed to be fitted directly onto diesel generator sets. RD-series load banks use the engine cooling air from the generator radiator to cool the load elements.
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0101
-
The AWS-0101 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and dual beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain during transmit mode, +15 dBm output power during transmit, and 3.4 dB NF during receive. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 QFN for easy installation in planar phased array antennas.
-
Product
Non-Linear Junction Detector
ORION™ 900 HX
-
The ORION 900 HX Non-Linear Junction Detector (NLJD) detects electronic semi-conductor components through dense materials such as bricks, concrete, and soil. The ORION 900 HX NLJD is made to detect and locate hidden cameras, microphones, and other electronic devices regardless of whether the surveillance device is radiating, hard wired, or turned off.
-
Product
Portable Spectrometers
-
*Quick search and detection of gamma radiation sources with radionuclide identification*Measurement of gamma radiation ambient dose equivalent rate
-
Product
Optical Sensors: Transmissometers
-
Transmissometers provide information about the optical properties of natural water by measuring the transmittance or attenuation of incident radiation. Sea-Bird Scientific offers transmissometers and an attenuation sensors for a variety of applications, including AUVs, deep ocean, and profiling floats.
-
Product
Antenna Mast
AM-400
-
The AM-400 antenna mast is suitable for making EMC radiated emissions measurements in an open area test site or test chambers.
-
Product
X-Band Silicon Radar Quad Core IC
AWS-0103
-
The AWS-0103 is a highly integrated silicon quad core IC intended for radar and 5G phased array applications. The device supports four radiating elements, single beam transmit, and dual beam receive and includes all requisite beam steering controls for 6 bit phase and gain control. The device provides 21 dB gain and +15 dBm output power during transmit mode and 7 dB gain and +7 dBm IIP3 during receive mode. Additional features include gain compensation over temperature, temperature reporting, and fast beam switching using eight on-chip beam weight storage registers. The device features ESD protection on all pins, operates from a +1.8V supply, and is packaged in a 56 lead 7x7 mm QFN for easy installation in planar phased array antennas.
-
Product
Turned Multiple Dipole Antenna
MODP2080
-
Antenna for Radiation Immunity Test on Car Max. Input Power : 12kW & High Erectric Field at = 4 : 100V/m Contolable the Height/Deviation by own unique Stand Patent Information.
-
Product
Fiber Optic Sensors
-
Leuze electronic GmbH + Co. KG
Plastic fiber optics are suitable for universal applications with low space requirements for object detection. Glass fiber optics are used in demanding environmental conditions with high temperatures and are resistant to chemicals. For radiation through foils or applications with high light power, they offer further advantages through the especially low damping. The flexible fiber optics with various head shapes can be integrated in nearly any system design. The detection range is dependent on the fiber optics and amplifiers used. Fiber optics can be used with the throughbeam principle or with scanning function. As a fiber array with multiple light beams, they can be used to detect especially small objects.
-
Product
Photomedicine Light Meters
-
Light meters for the measurement of optical radiation in therapeutic, diagnostic, ophthalmological, and endoscopic applications.
-
Product
Underwater Quantum/PAR Sensors
-
Photosynthetic radiation is essential for the growth of the photosynthetic organisms such as corals. The wavelength range from 400 to 700 nm is PAR (Photosynthetically Active Radiation) or PPFD (Photosynthetic Photon Flux Density). Apogee quantum/PAR sensors are calibrated to measure the number of photons of light across this range.
-
Product
Personal Gamma Radiation Dosimeter
EcotestCARD
-
The radiation monitoring badge EcotestCARD allows storing dose accumulation history with real time reference in the non-volatile memory, and communicating it to the computer. If the programmed threshold levels of gamma dose or its rate are exceeded, light and audio alarms are actuated.
-
Product
600MHz To 6GHz Radiation Measurement System
RMS-0660
-
The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces.
-
Product
Antenna, Octave Band Horn
EM-7020 | 1 GHz – 2.5 GHz
-
Electro-Metrics offers three horn antennas, each covering an octave bandwidth from 1 to 10 GHz. The horns are individually calibrated and can be used for either receiving or transmitting applications. They are especially suited to radiated immunity testing and can be used to generate fields in excess of 200 Volts/meter. All three horns feature type “N” connectors and exhibit low VSWR to ensure compatibility with power amplifiers.
-
Product
Rad-Hard Interfaces
-
Performance and flexibility are key words for ST's Interface ICs. Our latest generation of interface chipsets offer excellent immunity to radiation and high data rates while drawing very low consumption. Available with single-ended inputs/outputs (I/O) and also on differential tracks/cables with impedance matching, our space-qualified interface ICs accompany the decreasing voltage levels and the evolution toward serialization.
-
Product
RSE Wireless EMC Spurious Emission
TS8996
Test System
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
Product
DC Lab Power Supplies
TD3202M
-
- Fully Metallic Construction to Stop Radiated EMI- Compact & Rugged Design- DC Output ON/OFF on each Main Output- Voltage & Current Output Preset Facility for Safety- Constant Voltage / Constant Current Mode- 3 Digit DPM V and A- High Stability & Close Regulation ±0.01% +3mV- Low Ripple <1mV rms- Overload Protection- Convection Cooled – No Fans- Meets International Safety Standards
-
Product
Security & Search Systems
-
Discreet and robust gamma radiation detector, specifically designed for law enforcement and first responders to interdict nuclear and radioactive materials.
-
Product
EMI Test System
TS9975
Test System
The R&S®TS9975 is the base system for conducted and radiated EMI measurements. Due to its modular design, it covers a wide range of applications and can be very easily adapted to the measurement task at hand. Any configuration is possible – from conducted measurements and the small precompliance system with a compact test cell to the accredited test system for large equipment under test. Combinations of different applications or incremental expansion are easily possible.
-
Product
Spot Pyrometers
-
Fluke Process Instruments spot pyrometers are designed to be flexible and easy-to-install; durable to withstand the most demanding harsh industrial environments; and visual so you can see and understand your process temperature data. Spot pyrometers are a type of fixed thermal sensor used for measuring a single point on high-temperature surfaces, often in large furnaces or kilns. These devices measure temperature from the thermal radiation emitted, also known as radiometry.





























