Radiation
The transmission of energy through material or space.
-
Product
Radiation Monitoring Systems
-
Harnessing the energy of radiation safety. Our radiation monitoring systems enable the safe utilization of nuclear power as a transformative energy source.
-
Product
Field-installation Type MLSS Meter (Four-Wire Transmission)
HU-200SS
-
HU-200SS connects immersion type MLSS sensor (SS-90) and measures MLSS in activated sludge. A wide range (0-2000mg/L)of SS contents can be measured with excellent reproducibility using the near-infrared radiation transmission method. Any of the calibration curves of MLSS, Clay (inorganic mud) and Kaolin may be used as standard substances of SS. If "MLSS" is selected for an activated sludge treatment tank, "Clay" for the precipitation treatment of construction sludge, or "Kaolin" for white mud, a concentration can be obtained closer to an analyzed value.
-
Product
Plane Wave Converter
PWC200
-
The R&S®PWC200 Plane Wave Converter is a bidirectional array of 156 wideband Vivaldi antennas placed in the radiating near field of the device under test (DUT). The phased antenna array can form planar waves inside a specified quiet zone within the radiating near field of the 5G massive MIMO base station for realtime radiated power and transceiver measurements (EVM, ACLR, SEM, etc.).
-
Product
Solar Simulation Systems
-
PET Solar Simulators consist of a Light Source with a built-in Lamp Power Supply. The Solar Simulator has an ellipsoidal reflector that surrounds the lamp and collects most of the lamp output. The radiation from the lamp is focused onto an optical integrator that helps produce a uniform diverging beam. The beam is diverted 90° by a mirror onto a collimating lens. Special filters are placed between the mirror and the collimating lens to shape the radiation spectra to match various air masses. The output is a uniform beam that closely matches the sun's radiation spectra for a given air mass. Various models offer different areas of illumination. Each model can be manufactured to simulate the sun's radiation for different air masses.
-
Product
Measuring System for Assessment of Optical Radiation Safety
IEC62471
-
The system is designed especially for the determination of optical radiation hazard exposures specified in IEC62471, such as actinic UV hazard exposure for the skin and eye, near-UV hazard exposure for the eye, retinal blue light hazard exposure, retinal thermal hazard exposure, thermal radiation hazard for eye and skin, for LED products, UV-Lamps, lighting sources, luminaires and etc.
-
Product
Electromagnetic Radiation Tester
KM 196
-
Kusam Electrical Industries Limited
Unit : Electric Field : V/m; Magnetic Field : mT. Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT. Range : Electric Field : 1V/m ~ 1999V/m. Magnetic Field : 0.01 mT ~ 19.99 mT. Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT. Reading Display : 3½ Digit Digital LCD display with Backlight. Frequency Range : 5Hz ~ 3500MHZ. Sampling Time : About 0.4 second. Measuring Mode : Dual Mode. Overload Alert : “1” appears on LCD. Sound & Light Alarm. Data Hold function. Auto Power Off. Average & Peak measurement. Low Battery Indication. Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH. Power battery : 9V Battery. Dimension : 63.6 x 31 x 125.8mm. Weight : Approx. 146g.
-
Product
600MHz To 4GHz Radiation Measurement System
RMS-0640
-
The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces.
-
Product
Data Logger for Weather Station, 4G
HD33MT.4
-
HD33MT.4 with 4G/3G/2G/GPRS modem. Optional Ethernet. Designed for solar power. Integrated charger. Data Logger for weather station - remotely monitoring temperature, humidity, atmospheric pressure, solar radiation, rainfall quantity, wind speed and direction. Calculating sunshine duration.
-
Product
Non-Linear Junction Detector
ORION® 2.4 HX
-
The ORION 2.4 HX Non-Linear Junction Detector (NLJD) detects electronic semi-conductor components in walls, floors, ceilings, fixtures, furniture, containers, or other surfaces. The ORION 2.4 HX NLJD is made to detect and locate hidden cameras, microphones, and other electronic devices regardless of whether the surveillance device is radiating, hard wired, or turned off.
-
Product
Gamma Spectrometer
-
A gamma spectrometer is a specialized instrument used to detect and measure the energy of gamma rays. It works by converting the high-energy gamma rays into electronic pulses, which are then analyzed to determine the energy distribution of the gamma radiation.
-
Product
Benchtop Near Infrared Analyzer
SupNIR-2700
-
Radiation in the wavelength range 780–2500 nm (12820 to 4000 cm−1).
-
Product
Pyranometer
SR15-A1
-
Hukseflux Thermal Sensors B.V.
SR15-A1 is a high-accuracy solar radiation sensor. It is” First Class” according to the ISO 9060:1990 standard and “Spectrally Flat Class B” in the 2018 revision. With its on-board heater, it is compliant in its standard configuration with the requirements for “Class B” PV monitoring systems of the new IEC 61724-1:2017 standard. SR15-A1 measures the solar radiation received by a plane surface from a 180 o field of view angle.
-
Product
Total Sulfur Analyzer
Model 6200T
-
Teledyne Analytical Instruments
The Model 6200T Total Sulfur Analyzer utilizes proven UV fluorescent technology to continuously detect sulfur found in inert gas streams. An internal, quartz catalytic converter is employed to convert the sulfur, when mixed with scrubbed ambient air, into SO2 via higher temperature oxidation. An internal vacuum pump is employed to draw both the sample and the ambient air into the converter. The converted sample gas is fed to the fluorescence chamber where it is then exposed to ultraviolet radiation.
-
Product
MARATON Hazardous HE
-
MARATON is a family of MAgnetic field and RAdiation TOleraNt power supplies developed for CERN LHC. MARATON HHE is the 12 channel version for use in a hazardous hostile environment. Magnetic field tolerance is achieved by water cooling (up to 300G) and shielded components (up to 1200G). For radiation hardness (<30Gy) a quasi-redundant principle of power conversion is combined with special components. Further radiation sensible components are placed at remote locations.
-
Product
TDK Software
-
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
Product
Solar Radiation Sensors
-
The solar radiation sensors that Campbell Scientific offers come in a variety of designs: pyranometers, net radiometers, quantum sensors, and pyrheliometers. These sensors measure various aspects of the energy imparted by the sun on the Earth’s surface. A leveling fixture fitted with a bubble level may be required to accurately install solar radiation sensors.
-
Product
Antenna, Log Periodic
EM-6954 | 70 MHz – 1 GHz
-
The EM-6954 is designed to meet antenna requirements for both field strength measurement and radiated susceptibility in the 70 MHz to 1 GHz frequency range.
-
Product
Pixie Hybrid
-
The Pixie Hybrid is a multichannel data acquisition system for fast radiation detectors in nuclear physics and other applications requiring coincident radiation detection, and provides the following advantages:*Compatible with PXI-Express Hybrid or PXI chassis*Sophisticated data acquisition*Advanced pulse shape analysis*Scalability; several modules can be combined into larger system
-
Product
Magnetometers
-
The strength of magnetic fields can be determined with a magnetometer. Regardless of whether in the private sector or in the work environment, the increasing use of technology and networking also increases the exposure to magnetic and electromagnetic radiation. This radiation can have a negative effect on living beings, but also on sensitive electronic devices. Many effects are so unspecific that radiation is often not recognized as the cause. With a magnetometer you can measure how strong the radiation is at your sleeping place, in the kitchen in front of the microwave or induction stove or at your workplace. The location of sensitive electronic devices such as a precision balance can be examined with the magnetometer. The extent to which the radiation intensity increases or decreases with distance can be determined by positioning the magnetometer at various distances from the radiation source.
-
Product
Portable heat flux sensor, with read-out unit
HF03 / LI19
-
Hukseflux Thermal Sensors B.V.
The HF03 is a heat flux sensor that can be used in mobile applications. It is combined with LI19, a high accuracy hand-held read-out unit that can be used both for mobile measurements and as an amplifier directly connected to a PC. The combination HF03 / LI19 is typically used to study heat flux levels around flares and fires, and to calibrate flare radiation monitors / flare heat flux sensors.
-
Product
Monochromatic, Fiber-Coupled LED Light Sources
-
LED light sources in the LS-MC1 series provide a constantly growing selection – currently amounting to over 20 – of narrow band single wavelength LEDs with a bandwidth of 15-50 nm FWHM, allowing precise work in a defined wavelength range. As a result of optimized optical coupling into the optical fiber – as with all of our light sources – with our LS-MC1 series we have achieved the highest possible luminance. The advantage of directly emitting monochromatic LEDs is their very high level of efficiency, because the entire radiated output is in the useful wavelength range.
-
Product
UV Index Measurement
-
The sglux UV-Index sensors measure the UVI with a worldwide unique low measurement uncertainty of less than 5 %. This makes our sensors compliant to the highest measurement precisions class one according the DIN/EN 5031-11, chapter 8. Since 2018 our product UV-Cosine_UVI (ERYCA) is appointed for public authority tasks: The German Federal Office for Radiation Protection (BfS) services 27 measurement points in Germany for public information of the daily UV-Index. Twenty of these points (Andernach, Chieming, Duderstadt, Fichtelberg, Genthin, Giessen-Wettenberg, Schauenburg-Kassel, Langen, Lueneburg, Munchen-Neuherberg, Norderney, Belm/Osnabrueck, Schauinsland, Tholey, Todendorf, Waldhof-Falkenstein, Waldmuenchen, Wurmberg, Zingst and Zirchow) use the sglux ERYCA to obtain the local UV-Index value. In 2017 ARPANSA (Australian Government’s primary authority on radiation protection and nuclear safety) began replacing the existing biometers with SiC photodiode UV sensors (sglux ERYCA) at all network sites. There are currently thirteen measurement sites in Australia that have been upgraded to the new sensors.
-
Product
Electromagnetic Simulation Software Suite
EMTOOLS
-
EMTOOLS is a computational electromagnetic (CEM) software suite comprised of 16 different software codes. ACAL (Advanced Complex Algebra Library) is an out-of-core linear system solution library, using a hyper-matrix approach to partition the problem. The AntFarm™ (Antenna Farm) toolkit analyzes the radiation and electromagnetic interference (EMI) effects of single or multiple heterogeneous RF systems. Apatch™ software is an antenna design and analysis tool that provides antenna simulation and modeling by computing the radiation and receiving pattern of an antenna or antenna array installed in an operational environment...
-
Product
Geiger Counter
USB-RAD121
-
The USB-RAD121 is a radiation detector that runs completely off your computer's USB port. The device features a classic geiger counter click and light pulse for every count registered, while radiation levels are displayed on the computer. The simple RadGraph software interface displays and graphs readings over time, and even allows the readings to be streamed to a personal webpage.
-
Product
Multisensor Photo-Radiometer
HD2402
-
HD2402 is a portable photo-radiometer data logger for the measurement of noncoherent optical radiation in accordance with European Directive 2006/25/EC and the Legislative Decree No 81. The instrument consists of a series of sensors to cover different portions of the spectrum and a small laser which is used to indicate the analyzed source.
-
Product
TVAC Thermal Vacuum Test Chamber
-
Guangdong Test EQ Equipment co., Ltd.
- Space Environment Simulation: Replicates orbital conditions: thermal cycling, vacuum, and solar radiation (via optional xenon-arc lamps).- Precision Control: PLC-based automation with real-time data logging, remote access via LabVIEW/Modbus protocols.- Durable Construction: 304L stainless steel chamber, multi-layer MLI (multi-layer insulation), and vibration-damping mounts.- Safety Systems: Emergency venting, over-pressure relief valves, and redundant leak detection sensors.- Modular Design: Expandable with solar simulation, outgassing analysis, or cryogenic shroud add-ons.
-
Product
Ultimate Probe
-
The Ultimate Probe is an ultimate device that offers multiple test functions that reduces diagnostic time. Applicable to 12V to 24V vehicles with the ability to power components such as radiator fans, starter motors, relays, window regulators, windshield wipers, etc.
-
Product
Aspirated Radiation Shield
-
The fan has an ingress protection (IP) rating of 55, virtually eliminating moisture and dust ingress. At full speed the power requirement is 1 W (80 mA at 12 V DC). To conserve power fan speed can be reduced, via pulse width modulation (PWM), to 0.3 W at night or when wind speed is greater than 3 m s-1 without loss of accuracy. If the fan is continuously operated at full speed lifetime is rated at 50,000 hours (5.7 years). The fan includes a tachometer, allowing RPM to be mounted to detect obstruction of the fan.
-
Product
Precision Conical Dipole
PCD 8250
-
Exposure evaluation next to mobile communication facilities e.g. GSM and UMTS base stations. Accurate RF radiation safety measurements e.g. nearby broadcast stations or in buildings. All kinds of field strength measurements where high precision, a wide frequency range and small antenna dimensions are required. Measurements according to our Field Nose method. Frequency range: 80 MHz 3 GHz