Radiation
The transmission of energy through material or space.
-
Product
Spherical Blackbody Source
Cyclops Model 878
-
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers.
-
Product
Infrared Thermometer
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Thermometer which infers temperature from a portion of the thermal radiation sometimes called blackbody radiation emitted by the object being measured.
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
CBRN Detectors
Static Radiation Detectors
-
A static (or fixed) radiation detector is a device that monitors radiation in a single location. They are often used in areas of national security, such as airports, railways, and ship terminals.
-
Product
VHF/UHF Handheld Signal Location Antennas
Type NVF-2
-
The Type NVF-2 series of handheld directional antennas are used to locate interfering signals or noise in either the 420 – 470 MHz (Type NVF-2A) or the 900 MHz ISM band or cellular telephone bands (Type NVF-2B). Both models incorporate a solid reflector positioned behind a resonated half wave driven element, both elements being mounted on a fiberglass rod with an integral pistol grip. The configuration of the reflector and driven element are such that a deep null in the signal being received will occur when the antenna is pointed in the direction of the signal being radiated. A T-pad resistive attenuator is also incorporated in the antenna mounting enclosure to aid in the direction finding process on very strong signals or when excessive reflections present multiple returns.
-
Product
Field Intensity Tester
Model KM 828
-
Kusam Electrical Industries Limited
The meter can inspect particular objects or devices radiating low frequency electromagnetic waves. It can be used for power wire, computer monitor, TV, audio and visual, electromagnetic oven or analogous electrical installation.
-
Product
X-Scan D
-
The series has superior detection efficiency and up to ten times higher sensitivity than conventional cargo detectors, making it an ideal solution for high-throughput systems operating with low dose rates on high and medium radiation energies. The series comes with the state-of-the-art detector architecture with single and dual row pixel configurations.
-
Product
Embedded Assembly Systems
-
EASY (Embedded Assembly SYstem) is the CAEN high/low voltage power supply solution every time residual magnetic fields and/or radiation become an issue.
-
Product
RF Test
-
RF is short for radio frequency. RF is any frequency within the electromagnetic spectrum associated with radio wave propagation. When an RF current is supplied to an antenna, an electromagnetic field is created that then is able to propagate through space. Many wireless technologies are based on RF field propagation. These frequencies make up part of the electromagnetic radiation spectrum.
-
Product
Highly Sensitive, Lightweight Backpack Radiation Detector (BRD)
identiFINDER® R700
-
The identiFINDER R700 Backpack Radiation Detector (BRD) offers new spectroscopic broad-search capabilities. Once dismounted, the identiFINDER R700 provides the capabilities required to successfully perform wide-area searches quickly and efficiently while offering exceptional sensitivity, communication, and trusted spectroscopic algorithms in a lightweight, ergonomic form-factor.
-
Product
Personal Alarm
ND-10
-
Rugged Die Cast Aluminum Belt Worn Personal Alarm, Dual Range for Higher Radiation Areas
-
Product
Electromagnetic Interference Test
-
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
Product
Thermal Testing And Analysis
-
Response Dynamics Vibration Engineering, Inc.
We have consulted on thermal issues ranging from conduction issues in TECs, thermal radiation modeling, and countless air cooled system issues relating to system performance, vibration, and acoustics noise. We use a wide array of thermocouple instrumentation, thermal imaging, flow measurements, as well as finite element analysis and analytic modeling to measure, design, and debug thermal and related issues. We often work on customer products in our Response Dynamics lab where we characterize the system, engineer solution options, and prototype solutions. We then work with the customer to work the winning solution into their quality control and manufacturing process.
-
Product
Understanding TEM, TE, and TM Waveguide Modes
-
Energy can propagate through a medium or through what is currently believed to be a vacuum. Propagation modes vary depending upon the type of energy and the nature of the medium.Electromagnetic energy is transmitted in waves. Like sound, it may propagate equally in all directions, the wave energy radiating in concentric shells corresponding to amplitude. Or it may be directional, focused to form a tight beam.View more Understanding TEM, TE, and TM Waveguide Modes
-
Product
Chip Inductors-Multilayer
-
Bourns Miltilayer chip inductors offer high frequency, nickel barrier, monolithic construction for high reliability, and magnetically shielded construction providing low radiation. They are well-suited for DC-DC converters, and prevention of electromagnetic interference to signals on the secondary side of electronic equipment, among many applications.
-
Product
Gamma Detectors
-
In Gamma detectors, the gamma radiations produce electrons by interacting with the cathode material and the filling gas.These electrons ionize the gas and the charge carriers are collected by the electrodes. The resulting anode pulse is detected by a load circuit. The primary electrons are created by several interaction mechanisms:- Photoelectric effect- Compton scattering- Pair production
-
Product
Pyranometer
SR15-A1
-
Hukseflux Thermal Sensors B.V.
SR15-A1 is a high-accuracy solar radiation sensor. It is” First Class” according to the ISO 9060:1990 standard and “Spectrally Flat Class B” in the 2018 revision. With its on-board heater, it is compliant in its standard configuration with the requirements for “Class B” PV monitoring systems of the new IEC 61724-1:2017 standard. SR15-A1 measures the solar radiation received by a plane surface from a 180 o field of view angle.
-
Product
Lens Antennas
-
A lens antenna is a directional antenna that uses a shaped piece of microwave-transparent material to bend and focus microwaves by refraction, as an optical lens does for light.[1] Typically it consists of a small feed antenna such as a patch antenna or horn antenna which radiates radio waves, with a piece of dielectric or composite material in front which functions as a converging lens to collimate the radio waves into a beam.[2] Conversely, in a receiving antenna the lens focuses the incoming radio waves onto the feed antenna, which converts them to electric currents which are delivered to a radio receiver. They can also be fed by an array of feed antennas, called a focal plane array (FPA), to create more complicated radiation patterns.
-
Product
Spectroscopy
-
The branch of science concerned with the investigation and measurement of spectra produced when matter interacts with or emits electromagnetic radiation.
-
Product
Human Radiation Spectrometers
-
Human radiation spectrometer is designed for express control and measurement of the activity of 137 Cs and 134 Cs gamma-emitting radionuclides in the human body, as well as for assessing the internal radiation dose (“sitting in a chair” geometry).
-
Product
Radiation Force Balance
-
Radiation force balance for diagnostic and therapeutic medical ultrasound
-
Product
Thickness Check Calix
-
For the manufacturing of a perfect cold strip, many factors are crucial. Our measuring frames specifically check the thickness-related quality parameters of the strip steel or steel sheet. Free of radioactive radiation, laser sensors are used in the cold strip areas that do not require protection measures with laser class 2, or only low precautions when using laser class 3B sensors. The installation of our measurement systems is quick and uncomplicated for our customers. The CALIX is integrated into the line with its C-shaped frame across the material flow. Our solutions with and without traversing determine all important parameters for quality assurance, including strip thickness, edge thickness, wedge or cambering, and measure the complete thickness profile. Thus, you have full process control in the current production.
-
Product
24 TTL Channels, Enhanced, Programmable I/O
TL2
-
Function module TL2 provides 24 channels of TTL/CMOS transceiver functionality as either inputs or outputs. The transistor-transistor logic (TTL) employs transmitters with multiple emitters in gates having more than one input. TTL offers high switching speed and relative immunity to noisy systems. CMOS sensors provide image sensing technology by converting light waves into signals that are small bursts of current. These waves can be light or other electromagnetic radiation.
-
Product
Precision Conical Dipole
PCD 8250
-
Exposure evaluation next to mobile communication facilities e.g. GSM and UMTS base stations. Accurate RF radiation safety measurements e.g. nearby broadcast stations or in buildings. All kinds of field strength measurements where high precision, a wide frequency range and small antenna dimensions are required. Measurements according to our Field Nose method. Frequency range: 80 MHz 3 GHz
-
Product
Scanning X-Ray Detectors
Shad-o-Scan
-
Shad-o-Scan is a family of scanning X-ray detectors specifically designed for the challenging requirements of high-performance industrial and scientific X-ray applications. Industry-leading TDI CCD performance enables the ultimate sensitivity and highest resolution in the industry, and ensures long detector lifetime in even the harshest radiation environments.
-
Product
Gamma Spectrometer
-
A gamma spectrometer is a specialized instrument used to detect and measure the energy of gamma rays. It works by converting the high-energy gamma rays into electronic pulses, which are then analyzed to determine the energy distribution of the gamma radiation.
-
Product
Photomedicine Light Meters
-
Light meters for the measurement of optical radiation in therapeutic, diagnostic, ophthalmological, and endoscopic applications.
-
Product
Thermographic Camera
EXPEC 1810
-
A device that creates an image using infrared (IR) radiation.
-
Product
Radiation Hardened Solutions and High Reliability Components
-
Offering a complete portfolio of RadHard and HiRel components, CAES serves as the foundation on which many critical applications are built.