Sound Calibrators
assure sound measurement accuracy.
See Also: Sound Calibration, Acoustic Calibration
-
Product
Sound & Noise Meters
-
Lutron Electronic Enterprise Co., Ltd.
portable, handheld instruments with calibrated microphones that measure real-time noise levels in decibels (dB), simulating how the human ear perceives sound
-
Product
HIgh-Precision Frequency-Domain Sound Analyzer
The Snail
-
iNSTiTUT DE RECHERCHE ET COORDiNATiON ACOUSTiQUE/MUSiQUE
The Snail is a very high-precision frequency-domain analyzer that delivers an easy to understand representation of sounds based on the scales and notes aligned in spectrally active zones. It offers a new way of tuning and analyzing an instrument in an extremely accurate way, displaying intonation and visualizing music and sounds in a way that can help anyone improve their listening and innotation!
-
Product
Dynamic Calibration for ROSS Streak Cameras
DynaCal
-
The DynaCal Optical Calibration Module (OCM) is designed exclusively for the Sydor ROSS Streak Camera to ensure accuracy, both over time and in situ, so you can be confident that the data from your shot is certified to be correlated to the calibration of your camera. The beauty of in situ calibration is that the cost of removing and resetting the camera is avoided—and so is the risk of the replacement of the camera and shifting or disturbing the sensitive nature of streak camera results. Only in situ calibration will reveal the real world effects of EMR, gravity, electronic noise and more when they distort your camera results.
-
Product
Class 1 Integrating Sound Level Meter
Castle Sonus GA116I
-
The Castle SONUS GA116I is a feature packed instrument that is fully compliant with IEC 61672-1:2002 Class 1, and IEC61252: 1993. This meter gives simultaneous Leq (rms. average) personal exposure (LEpd) and peak measurement for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification, Class 1 measurement microphone and is cased in tough, crack resistant ABS plastic.
-
Product
Mobile Sound Ranging Array
MSRA
-
In a peer to peer conflict, weapon location radars used for counter battery purposes will be extremely vulnerable.With aerial/satellite based surveillance available for the opponent, radars will be seen. With electronic warfare means being omnipresent, radars will be triangulated and jammed. There is an urgent need for 24/7 persistent surveillance with (preferably) passive sensors. With mobility being the key for survival on the battlefield, rapid re-deployable, or even truly mobile sensor capabilities are required. Therefore, the traditional sheer sound pressure based sound ranging capability becomes obsolete, as the triangular footprint of the sensor nodes is too large to be installed on a manned, or unmanned platform. With the trend towards longer ranges and “shoot and scoot” drills, the concept of capturing the muzzle blast noise becomes questionable, as the speed of sound is too slow to provide timely localizations.
-
Product
Waterproof Infra-Red Turbidimeter (NTU) with calibration kit
TN 100
-
The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigor of rugged field applications. It is a "must -have" for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).
-
Product
Laser Calibration System, Superior Accuracy, Portability and Reliability
5530
-
The configurable system offers all the components you need to perform a variety of measurements using the USB on your PC as the host controller and power source. For basic linear measurements you will need the USB Axis Module, USB Sensor Hub, Air and Material Sensors, Sensor Cables, Software, Laser, Laser Cable, Remote Control (optional)and the Linear Optics Set. Other available options include the Laser Tripod (with laser mounting plate), optics and fixturing kits for making additional types of measurements, and wheeled transit cases.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6B
-
The CAL-SMA-6B Basic calibration kit provides the elements for performing Open–Short–Load and Through calibrations for one and two port VNA measurements.
-
Product
Electrical Calibration
GF6018A
-
Beijing GFUVE Electronics Co.,Ltd.
The equipment is compliance with national verification regulation: JJG1242005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
-
Product
CALIBRATOR Multi Function Calibrator
MC140
-
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
Product
Precision Sound Level Calibrator
CAL200
-
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
Product
Open-Short-Load RF calibration kits
-
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
Product
Class 2 Integrating Sound Level Meter
Castle Sonus GA216I
-
The Castle Sonus GA216i is a feature packed instrument, fully compliant with IEC 61672:2002 Class 2. This meter gives simultaneous Leq and peak measurements for assessments to the Control of Noise at Work Regulations 2005. It has a high-specification measurement microphone and is cased in tough, crack resistant ABS plastic. To comply with the Control of Noise at Work Regulations 2005, this Class 2 Sound Level Meter enables you to assess Noise in the workplace at fantastic value.
-
Product
PXIe-4480, 1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module
784277-01
Analog Input Module
1.25 MS/s, 3.4 Hz AC/DC-Coupled, 6-Input PXI Sound and Vibration Module—The PXIe‑4480 is designed for high-bandwidth audio, acoustic, and vibration measurements. It provides six channels of dynamic signal acquisition, and you can use one of four gain settings to configure your input range. The PXIe‑4480 also includes software-configurable AC/DC coupling, charge measurement, voltage excitation, IEPE excitation, and TEDS support, making it ideal for measuring acoustic transducers, pressure sensors, and hydrophones. Common applications include audio test; noise, vibration, and harshness (NVH) analysis; and underwater acoustic measurements. For measuring sudden changes, such as high speed blast and pressure events, the PXIe-4480 can sample up to 20 MS/s per channel in time-domain mode.
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Trace Level Portable Gas Calibrator
Model T750U
-
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
Product
Calibration Services
-
Tempsens Calibration Centre is an independent unit of Tempsens instruments (I) Pvt. Ltd. We have calibration laboratories at Vadodara (Temperature Range for Contact Type Sensors -196 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C) and Bangalore (Temperature Range for Contact Type Sensors -35 to 1600 deg C and for Non-Contact Type Sensors 50 to 1700 deg C).
-
Product
Calibration Software
-
Simplify your calibration through advanced software from Transmille. ProCal can automate your test equipment and increase productivity while reducing errors.
-
Product
Acoustic Calibrators
-
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
Product
Class 1 Integrating Sound Level Meter System
NK021
-
This NK021 system includes a class 1 integrating sound level meter, class 1 acoustic calibrator, protective microphone windshield and is supplied in a hard wearing kit case.
-
Product
OEM Sound Velocity Sensor
ultraSV
-
The next generation of sound velocity sensor, the UltraSV, is ultra-fast, ultra-compact, ultra-dependable.
-
Product
DBAir Sound Meter System For Safety Managers
05NK101
-
Designed specifically for Safety Managers, the dBAir Safety Managers System comprises everything you require to carry out assessments to the Control of Noise at Work Regulations 2005, as well as being the ideal system for International Occupational Health Monitoring.
-
Product
Four Channels Sound and Vibration Analyser
SVAN 958A
-
The SVAN 958A is a Class 1 four-channel sound and vibration analyser built for applications requiring simultaneous and independent multi-channel measurements.
-
Product
PLTS Advanced Calibration
N19305B
-
PLTS N19305B extends the N19301B base product to perform advanced calibration techniques such as Automatic Fixture Removal (AFR)
-
Product
Sound Level Meters & Decibel Meters
-
Find high performance easy to use Class 1 or Class 2 sound level meters. Ideal professional-grade noise meters for accurate and compliant noise measurement for every application including occupational noise and environmental noise.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
6GHz SMA Calibration Kits
CAL-SMA-6F
-
The CAL-SMA-6F Full calibration kit provides all elements for Male and Female Open-Short-Load and Through calibrations for one and two port VNA measurements.





























