Leakage Current Clamps
Measure low current emf surrounding a conductor.
-
product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
product
Automatic Current Tester
77069
For the rapid safe and accurate testing of DC current on 12v vehicles. The tool plugs straight into the vehicles fuse board and displays the current on the large LCD display. Specification range 0-48volt max 20 amps, 12v battery included.
-
product
DC current Sensors
CTH
The CTH sensors convert dc current to an isolated voltage output, the CTHR sensors convert ac current to a dc output signal proportional to the Arms. All popular process control voltage and current loop outputs are available. Through hole or split core options mean that connection is non-intrusive and straightforward. The available input range of the CTH sensors is any value from 5A to 6000Adc.
-
product
Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 4 Channel
CX3324A
The CX3324A is a 4-channel model for engineers and researchers who need more than two channels for current waveform measurements at one time. Using a passive prove interface (CX1151A) with a current sensor (CX1101A, CX1102A, CX1103A) enables power measurements. The bandwidth and the memory depth per channel are option and can be selected from 50 MHz, 100 MHz and 200 MHz, and 16 Mpts, 64 Mpts and 256 Mpts, respectively. Upgrade products for both bandwidth and memory depth options are also available for customers who need more performance after purchasing the product. 8-channel digital channel (CX1152A) can be used with this 4-channel model so that you have more flexibility of triggering.
-
product
SHC68-C68-D4, Shielded Single-Ended Cable, Low Leakage, 1m
152870-01
68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, Shielded Digital Cable - The SHC68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is a shielded, 50 Ω cable and is offered in different lengths.
-
product
Handheld Clamp Meter, 3 ½ Digit
U1212A
Handle large currents up to 1000 A safely with 2-inch large jaw opening. Keysight Remote Link Solution allows datalogging wirelessly via Bluetooth.
-
product
Light-to-Analog Sensors (Current)
Renesas' light-to-current silicon optical sensors combine a photodiode array and current amplifiers on a single monolithic IC. These devices are ideal for display and keypad dimming, as well as industrial and medical light sensing applications.
-
product
Precision Pulsed Current Sources
SpikeSafe Performance Series
SpikeSafe™ Performance Series Current Sources supply DC and precision continuous or single pulse current for light measurement and other applications. With sustained output power and no duty cycle limitations, Performance Series Current Sources support a broad range of applications.
-
product
Through Hole type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-45NK
MULTI MEASURING INSTRUMENTS Co., Ltd.
*DC earth fault measurement*DC leakage current measurement*Least affection from the magnetization of core and temperature fluctuation*Convenient +24V single polarity power supply
-
product
ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
Chongqing Assen Power Equipment Co., Ltd
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
-
product
AC/DC Clamp Meter
CM4374
• AC/DC Clamp • True RMS • 600/2000 A range • V, A, Hz, Ω, and other extensive measurement parameters • Inrush current • Max/Min/Avg/Peak • Wireless data download to a tablet or smartphone
-
product
16 SE Or 8 Diff. Input Channels, 8 Analog Current Output Channels, PCI Express
APCIE-3121-16-8C
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
product
Precision Multirange Current Transformer
P-2000
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
product
Current Calibrators
Used for basic measurements, tests and regulation techniques for setting and verifying test installations and instrumentation.
-
product
Flexible Monitoring of Voltage & Current in A 2 B ® Networks
Line Test Box LTB 1024
The Automotive Audio Bus (A 2 B ® ) from Analog Devices Inc. reduces the complexity of audio systems. In addition to the automotive industry, it is also increasingly being used in other areas such as conference systems. We have developed a line measuring device specifically for this A 2 B ®technology: the Line Test Box LTB 1024.
-
product
200 Amp AC Current Adaptor
DL6701
The DL6701 is a compact 200A AC current clamp adaptor with voltage output via standard 4 mm connectors. To be connected to a digital multimeter or other voltage measurement device.
-
product
Integrated Two-Stage Current Sensors
If ultra-low noise performance is required, our integrated two stage devices are the number one choice. With input inductances from 24 nH to 1.8 µH and a flux-noise level as low as 0.8 µPhi0/sqrt(Hz) an energy resolution of about 45 h is attained. The devices consist of a 16 SQUID series array as amplifier stage and a single front-end SQUID.
-
product
Field Current Regulator
We are counted amongst the leading names in the industry, offering wide range of Field Current Regulator. Our entire product line ensures easy operations and is performance based. Field Current Regulator are quality tested and are delivered in standard configurations. Our entire product range has high strength and is delivered at most affordable rates.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
43-752A-911
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
Current Caliper
KH23101
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
product
Compact AC Auto Ranging Clamp Meter
410001
The small bodies and jaws fit perfectly in your hand and into tight places. Meter controls are positioned so that current measurements can be done with one hand. A large backlit display is easy to see, and the handy display hold function keeps measurements fixed on the display. Measures starting current for motors, lighting, etc.
-
product
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse
T3CP30-100
30A, 100 MHz CURRENT PROBE, BNC, AC/DC, 30A rms, 50A Peak Pulse.
-
product
Self-reclosing Overcurrent And Residual Current Protection
Wide range of solutions to guarantee personnel safety as well as maximum service continuity in the event of a ground current or breaker trip, with automatic reconnection of the installation. Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
product
Integrated Current Sensors
GO series
*Standard package and small footprint*Cost effective*A perfect compromise for small drives, robots, solar inverters, e-bikes etc.





























