Current
See Also: Direct Current, Alternating Current, Resistivity, Flow, Inductance
-
Product
High 1.80 (51.00) - 12.60 (357.00) Switch Probe
TSP138-C180-3
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 138Test Center (mm): 3.50Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,760Overall Length (mm): 44.70Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
H/L Voltage Clamp Meters
-
High Voltage Current Transformation Ratio Tester breaks traditional structure, specially designed for high and low voltage first and secondary loop current, variable ratio, and current leakage test; apply the latest CT technology and mask digital integration technology, composed of special high-voltage clamp, low voltage clamp, host, high voltage insulation rod and monitoring software, etc; its wireless transmission test data can penetrate multiple building obstacles with a straight-line distance of 30 meters.
-
Product
High 1.73 (49.00) - 8.00 (127.00) High Performance Lead Free Probe
LFRE-1T1-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Monochromatic, Fiber-Coupled LED Light Sources
-
LED light sources in the LS-MC1 series provide a constantly growing selection – currently amounting to over 20 – of narrow band single wavelength LEDs with a bandwidth of 15-50 nm FWHM, allowing precise work in a defined wavelength range. As a result of optimized optical coupling into the optical fiber – as with all of our light sources – with our LS-MC1 series we have achieved the highest possible luminance. The advantage of directly emitting monochromatic LEDs is their very high level of efficiency, because the entire radiated output is in the useful wavelength range.
-
Product
Resistance Bridges
-
Provides the best in measurement uncertainties for Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
Product
Fluorescent Lamp Asymmetric Pulse Tester
UI2002C
-
UI2002C is designed according to the latest update in IEC 61347-2-3 about the test requirements for local rectifying effects on tubes. It imitates the condition when tube is under local rectifying status and tests the abnormal protection function of ballast by adopting fluorescent lamp asymmetry pulse test method with 3 windows for displaying rectified voltage, rectified current, and rectified power. It is easy for operation and with high test accuracy. • Measure lamp voltage, lamp current , average and total power of lamp. • Lamp voltage range: 10~300V • Lamp current range: 10mA~1.0A • Lamp power range: 0.5~300W • Tolerance is 5%
-
Product
Module Testing Station
QuickSun® 550CE
-
QuickSun 550CE is certified by TÜV Rheinland and a detailed test report is included with every simulator proving Class A+A+A+ performance with respect to spectrum, irradiance non-uniformity and short term instability (STI). Long term instability (LTI) is also within Class A+ tolerances during the 40 ms long flash pulse. IV characteristics are recorded with an electronic load and proprietary electronics unit which measures voltage, current and irradiance signals when module is swept e.g. from short circuit to open circuit or vice versa.
-
Product
Keysight Dual/Quad 4x8 Reed Matrix for 34980A
34933A
Matrix Switch Module
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
Product
VME64X 7U 16 slot with P0
101V64XM16-0621R
-
7U VME64x Backplane 16-slot with P0, compliant with ANSI/VITA 1.1-1997, VME extension, and VITA 1.7 Increased Current. The extra 1U provides room for extra power bugs or busbars. Includes termination passive inboard and daisy chain automatic active.
-
Product
Insulating Boots (Gloves) Withstand Voltage Tester
-
Weshine Electric Manufacturing Co., Ltd
80KV Insulation Boots Withstand Current Leak Testing Withstand Voltage Tester
-
Product
LFRE-1 High Performance Lead Free Probe
LFRE-1
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PIN Diodes
-
PIN photodiodes convert light to current – without a bias voltage having to be applied. Silicon is commonly used as an inexpensive detector material in the Vis range. For higher demands, InGaAs is used; it covers the widest spectral range from the Vis to the NIR. We offer silicon carbide as a “solar-blind” detector specifically for the UV range.
-
Product
Circuit Breaker Testing
-
Weshine Electric Manufacturing Co., Ltd
Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
Alternate 2.54 (72.00) - 6.20 (176.00) General Purpose Probe
HPA-52T-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
Product
PXI-4130, ±20 V, ±2 A DC, 40 W PXI Source Measure Unit
779647-31
Programmable Power Supply
±20 V, ±2 A DC, 40 W PXI Source Measure Unit - The PXI‑4130 is a programmable source measure unit (SMU). It has a single isolated SMU channel that offers a four-quadrant output that incorporates remote (4‑wire) sense. With its five current ranges, it is ideal for transistor characterization that requires accurately sourcing a constant current or voltage while sweeping another current. The PXI‑4130 also includes a utility channel that can source either current or voltage. This PXI SMU can act as either a constant voltage source or a constant current source, with a settable compliance limit for either mode. In addition, you can enable remote sense on the SMU channel to maximize voltage output and measurement accuracy on your device under test (DUT) for high-precision applications.
-
Product
12-bit, 200KHz, 8SE/4DIFF Isolated AI, 4 12-bit AO, 8 Optically Isolated Dig. I/O, 24V, 24 TTL I/O
APCI-3110-8
-
The APCI-3110 is a 12-bit multifunction board for 3.3 V and 5 V PCI systems, with optical isolation up to 1000 V and a high throughput rate of 200 kHz. The PCI board has additional types of conversion: Sequence RAM, Auto Refresh, scan, timer or external event.Furthermore, the board has a PCI DMA, 2 watchdogs, 4 digital inputs and 4 digital outputs. Sensors, which allow to supply current signals instead of voltage signals, also can be acquired with the APCI-3110, as this board offers up to 16 current inputs. The board is protected against overvoltage and input filter and it is protected against high frequency emmission. With the free calibration tool you can do the fine adjustment on-site.
-
Product
Semiconductor Curve Tracer
CS-5000 Series
-
*Max. Peak Voltage : 5,000V(HV mode)*Max. Peak Current : 1,500A(HC mode)*Equipped all models with LEAKAGE mode (Cursor resolution 1pA)*USB port for display hardcopy, waveform data (CSV format) and measurement setup SAVE/RECALL*LAN interface for Remote Control
-
Product
PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply
781155-01
Programmable Power Supply
2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.
-
Product
DC Power Supply
62000H
-
Chroma Systems Solutions, Inc.
Chroma’s new 62000H Series of programmable DC Power Supplies offer many unique advantages for telecom, automated test system & integration, industrial, battery charge & simulation for hybrid cars and solar panel simulation. These advantages include a high power density of 15KW in 3U, precision readback of output current and voltage, output trigger signals, as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations. For high power applications, parallel up to 10 units for up to 150kW.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25I8-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1H-7-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Circuit Breaker Analysis Systems
-
When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur. The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.
-
Product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
-
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1V-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Logger with Current Clamp0.15 to 200A
TGP-4810
-
A data logger, housed in a rugged case, supplied with a Chauvin Arnoux Current Clamp . This unit is ideal for mains and power consumption monitoring.
-
Product
MCB Magnetic (Instantaneous) Trip Test Bench
-
The test bench is specially built for low voltage- B, C & D curve MCBs. Specially designed custom built jigs are able to accommodate single, double, three and four pole MCBs. Decades of experience has helped us to design current source (transformer) in a special way such that good current regulation and high accuracy is ensured with a variable range without the use of any variable transformer in the system. The product is better than the competition with conventional technology at a lesser price!
-
Product
PCI Express 16 Reed Relay Output
8004e
-
The 8004e PCI Express digital I/O interface provides 16 optically isolated inputs and 16 Reed relay outputs. The isolated inputs protect the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments. The outputs provide high quality, long-life, dry contact switch closures suitable for low-current applications.
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Bias Ball Probe
POGO-1I35-7-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02