-
product
Heated Type NOx Analyzer
MEXA-1170HCLD
The MEXA-1170HCLD is available as an atmospheric (A) and a vacuum (V) model. With nine ranges available from 10 ppm up to 10,000ppm, these instruments are designed to fit most applications in the industry.
-
product
High Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200H
Teledyne Advanced Pollution Instrumentation
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also available).The T200H may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.
-
product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
product
High Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200H
Teledyne Advanced Pollution Instrumentation
The Model N200H uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of high-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Chemiluminescence NOX-NO2-NO Analyzer
Model N200
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
product
Transportable NOx-O2 Gas Analyzer
NOA-7100
The NOA-7100 adopts the normal pressure chemiluminescence method is adopted for NOx measurement, and the zirconia method is adopted for O2 measurement. NOA-7100 is “All-in-one portable analyzer” that incorporates the pretreatment parts needed for measurements. Switching between eight ranges from 25 to 4,000 ppm supports a wide range of NOx measurements. The NOA-7100 has wireless communication capability, so measurement values and charts can be displayed on PCs or smart devices. And measurement data can be exported using a USB flash drive.
-
product
CO & NOX Analyzer
714
Combustion Efficiency Analyzer. NO & NOX Analyzer. CO Analyzer(calculatesCO2). Differential Thermometer. Differential Digital Manometer
-
product
Solid-State Chemiluminescence NOx Analyzer
CL3020
CL3020 CLD NOx analyzer utilizes next generation solid state detection technology to measure low and ultra-low NOx in combustion applications.
-
product
Trace-Level Chemiluminescence NO/NO2/NOx Analyzer
Model T200U
Teledyne Advanced Pollution Instrumentation
The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.
-
product
Chemiluminescence NH3 Analyzer
Model T201
Teledyne Advanced Pollution Instrumentation
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter (see "Features" tab for external converter photo) to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.
-
product
Marine Emissions Analysers
Protea 2000
The Protea 2000 emissions monitoring system is approved for the analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2, CO2 and NOx.
-
product
Gas Analyzers
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
-
product
Stack Gas Analyzer
GI-700 series
Experience HORIBA, the Global Single Source Solutions Provider with over 50 years of technological advancements and unparalleled reliability, dependability and operability.The GI-700 stack gas analyzer is designed to continuously measure the concentrations of nitrogen oxides (NOx), sulfur dioxide (SO2), carbon monoxide (CO), carbon dioxide (CO2), oxygen (O2), and ammonia (NH3) in stack flue gas streams.
-
product
Stack Gas Analysis System
ENDA-5000 series
Continuous simultaneous and high-precision measurement of NOx, SO2, CO, CO2 and O2.HORIBA has over 100,000 CEM systems installed and 30 years of quality and experience. That is the base on which HORIBA's new ENDA-5000 series of stack-gas analysis systems are built. These systems have a small footprint and use cross-flow modulated non-dispersive infrared (NDIR) and magneto-pneumatic detectors that are inherently drift-free. The ENDA-5000 series are superior continuous analysis systems that perform reliably for difficult exhaust gas measurements, when measurement errors cannot be tolerated. This CEM series features a new intuitive touch panel that makes every operation available with the touch of a single button. The ENDA-5000 series systems are also designed for ease of maintenance. They are ideal for a variety of uses, including emissions monitoring from steam boilers, refuse incinerators, and electric power generation plants to assure pollution standards are being met.
-
product
Ambient Air Quality Monitoring System
AQMS
AQMS, the doctor for "Human Health"An Air Quality Monitoring Station (AQMS) is a system that measures metrological parameters such as wind speed, wind direction, rainfall, radiation, temperature, barometric pressure and ambient parameters. The AQMS also integrates a series of ambient analyzers to monitor the concentration of air pollutants (such as SO2, NOx, CO, O3, THC, PM, etc.), continuously. HORIBA also provides mobile monitoring stations that can be used to monitor ambient conditions at multiple sites.
-
product
Combustion
Our combustion gas analysers are compatible with a wide range of machines, such as engines, industrial boilers, incinerators and industrial furnaces. They can be used to assess various combustion parameters, from efficiency and yield to CO, O, NOx and other gas concentrations in flue and exhaust gases.
-
product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/Printer
C165+NKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/ Oil-Fired Appliances/ Printer
C165+NOILKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Chemiluminescence Ammonia Analyzer
Model T201
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.The Model T201 achieves its remarkable stability by means of an AutoZero valve which measures and corrects for zero noise. Multiple self-checks are performed continuously to insure maximum up-time while an innovative sample path, plumbed with specially conditioned materials, preserves the NH3 sample and reduces interferents to a minimum. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.The Model T201 comes with the Numaview™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
product
Mid-Range Chemiluminescence NO/NO2/NOX Analyzer
Model T200M
Teledyne Advanced Pollution Instrumentation
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers.
-
product
Air Quality Analysis
Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
High CO & NOX Analyzer
715
Combustion Efficiency Analyzer. NO & NOX Analyzer. CO Analyzer(calculates CO2). Differential Thermometer
-
product
Stack Gas Analyzer
ENDA-7000 Series
After decades of experience in precise stack gas measurement, HORIBA's brand new ENDA series represents the ultimate stack gas analyzer. With enhanced lower cost and reduced maintenance time, high sensitivity, and usability, we focused on the users' point of view. The ENDA-7000 is designed to continuously measure the concentrations of NOX, SO2, CO, CO2, O2, and NH3 in stack flue gas streams. The model is offered in dozens of combinations based on your measurement requirements. The ENDA-7000 uses an extractive method which measures undiluted sample gases, and is very suitable to stack gas measurements such as shale gas, LNG, or biogas and other combustion applications. The ENDA-7000 is an excellent choice for measurements in power generation facilities, boilers, furnaces, steel manufacturing, cement plants, pulp and paper mills, etc.
-
product
Residentia/Commercial Combustion Analyzer w/ Pressure/NOx
C164
UEi Test & Measurement Instruments
The C164, with EOS Technology, eliminates the number one hassle experienced by HVAC technicians, the cost and down time of replacing the O2 sensor. The EOS award-winning technology for combustion analysis replaces the everyday electro-optical sensor with EOS CO2 technology, lowering the cost of ownership. The C164 offers direct CO2 measurement and features a 30 second start up time.
-
product
Residential/Commercial Combustion Analyzer w/ NOx Sensor
C165+N
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
On-Board Systems
OBS-ONE series
HORIBA developed the OBS-ONE series on-board emission measurement system in response to new requirements for exhaust emissions measurement from vehicles being driven on public roads (Portable Emissions Measurement Systems - PEMS). This development has been made possible by reducing the dimensions and power consumption of laboratory grade analyzers and ensuring that the system components have excellent vibration resistance. The OBS-ONE series continuously measures not only the concentration of CO, CO2, THC and NOx, but also measures exhaust fl ow rate and A/F ratio to calculate mass emission and fuel economy.
-
product
Dilution-Extractive System
ML675
The Teledyne ML®675 dilution-extractive system can be used in 40CFR75, 40CFR60, 40CFR63, and process control applications. In this system, sample is prepared for analysis by diluting stack gas with clean, dry instrument air at the probe location. Since no moisture is removed with dilution, measurements for SO2, NOx, CO, THC and CO2 are made on a wet basis.
-
product
Mid-Range Chemiluminescence NOX-NO2-NO Analyzer
Model N200M
Teledyne Advanced Pollution Instrumentation
The Model N200M uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases for use in extractive type CEM systems.
-
product
Continuous Gas Analyzer In Flue Gas
NSA-308
The NSA-308 can measure five components NOx, SO2, CO, CO2, and O2 in exhaust gas from incineration facilities, etc. Two analyzers are used, a high-performance, high-functionality ratio infrared analyzer and a magnetic wind oximeter.





























