VDE
Verband der Elektrotechnik
-
product
Voltmeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.
-
product
Rotary Field Direction Indicator According to DIN EN 61557-7 (VDE 0413-7)
PeakTech Prüf- und Messtechnik GmbH
Direction indicators are indispensable for use in the electrical assembly of three-phase motors. This offers two different functions for displaying the direction of rotation. I
-
product
Resistance Measuring Device According to DIN EN 61557-4 (VDE 0413-4)
PeakTech Prüf- und Messtechnik GmbH
An extremely robust milliohm measuring device in a splash-proof hard case for professional field service use, e.g. for resistance measurement on motor coils, generators and transformers or for continuity testing on ring bus systems in industrial plants.
-
product
Loop Resistance Measuring Device According to DIN EN 61557-3 (VDE 0413-3)
PeakTech Prüf- und Messtechnik GmbH
A loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Biconical Antennas
For many years most standards called for the use of a half-wave dipole antenna set for frequencies above 80 MHz. However, to reduce test time, broadband antennas such as the biconical antenna and log periodic antennas began to be accepted. Broadband antennas, compared to half wave dipoles, reduce test time because the technician did not have to stop the test to adjust the dipole antenna for each frequency. A.H. Systems'' 7 models of Biconical Antennas operate efficiently over the frequency range of 20 MHz to 18 GHz. Suitable for FCC, MIL-STD, VDE, TEMPEST, and immunity testing, each Biconical antenna will provide reliable, repeatable measurements.
-
product
IEC60335 Inclined Plane Test Table for Stability Test
CX-W600
Shenzhen Chuangxin Instruments Co., Ltd.
It's to determine the stability of electric appliances which are used on a table or on the floorin accordance with IEC 60065 / 1998-07 clause 19.1, IEC 60335-1 / 1991-04 clause 20.1, IEC 60601-1 /1988 clause 24.1, IEC 60950 / 1991 + Amendments, modified, clause 4.1.1,EN 60335-1 / 1994 and A11 / 1995 clause 20.1, EN 60950 / 1992 + Amendments up to 1997 clause 4.1.1,VDE 0700 Part 1 / 10.95 clause 20.1 and Part 3 / 3.96 clause 20.1, VDE 0730 Part 1 / 3.72 clause 20a,VDE 0805 / 11.97 clause 4.1.1Inclined Plane Device is used to test the stability of an apparatus that requires a surface in order to work.The device cosist of a surface and an angle adjusting device with 0- 15 °
-
product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
product
High Voltage Multifunction Phasing Sticks
PC7K / PC11K / PC22K / PC33K / PC44K
Kusam Electrical Industries Limited
* Designed to Exceed VDE 0681 part 5.* Dual Color Coded Scale (%, Vac).* Neon indicator lit when >1200 Vac.* Compare between Phases.* Measure and test Phase to Earth.
-
product
Insulation Meters
Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.
-
product
PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit
APCI-3501-4
4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V
-
product
Insulation Measuring Device According to DIN EN 61557-2 (VDE 0413-2)
PeakTech Prüf- und Messtechnik GmbH
This digital insulation measuring device is required for various measurements of cables, components and their insulation.
-
product
General Power Relays
Panasonic Industrial Devices Sales Company of America
2A and greater load rating in Polarized, Non-Polarized, High Capacity DC, General Purpose, and Safety configurations. UL, CSA, C-UL, TUV, VDE, and SEMKO certifications.
-
product
[5kV AC] Hipot Tester, Rise/Fall-Time Control Function Equipped
TOS5200
TOS5200 is designed for AC Hipot Test with 500 VA capacity and 200 mA short circuit current output capability. Equipped with the PWM amplifier, the TOS5200 can provide a stable & reliable output without being affected by ACpower line. Therefore, it is a perfect solution for electronic equipment or devices complied to IEC, EN, UL, VDE andJIS etc. requirement.As TOS5200 covers most of features of our upper class model for AC Hipot Test, it achieves thesuperb cost / performance ratio for those who need 200 VA or 500 VA capacity, or both. Also, as it equips the Interlockfunction together with other safety features, operator can carry out the test with higher current value in safe.
-
product
Ammeter According to DIN EN 61010-1 (VDE 0411-1)
PeakTech Prüf- und Messtechnik GmbH
Is a measuring device for AC and DC currents up to 1000 A using a current clamp for conductor diameters up to 48 mm. Current and voltage measurements are carried out as true RMS (true rms value) measurements, which means that the measured values are displayed correctly even with waveforms that deviate from a sine wave.
-
product
Earth Resistance Tester
PeakTech Prüf- und Messtechnik GmbH
A Rugged sealed digital earth tester is built with all the protection you need for outdoor use. The instrument is suitable for the testing of single earth electrodes such as lightning conductors and other small earthing systems according to VDE 0413. The resistance of conductors such as continuity and conduit coupling joints can also be measured. Two-terminal operation measurement, which reduces the accuracy, can also be done by shorting P and C terminals. It has an advanced circuit design that permits the instrument to operate with the minimum influence from earth voltage and earth resistance of the auxiliary spikes.
-
product
Combination Measuring Devices According to DIN EN 61557-10 (VDE 0413-10) are permitted
PeakTech Prüf- und Messtechnik GmbH
This innovative combination measuring device for testing electrical installations according to official laws convinces with its technical performance data in the high-end area. All important safety tests such as FI, voltage, loop, low-resistance, earth resistance and insulation tests for e-checks and new installations can be carried out safely by the electrician via the large 3.5“ TFT color display. Of course, the device comes with an extensive range of accessories, such as all necessary test leads, adapters, rods and the required software CD for the PC. The device can be charged with a power adapter or via a car adapter. During the daily use, this high-quality device is protected against dust and all-round water jets by its protection class IP 65.
-
product
Power Frequency Transducer
PP1S
1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540
-
product
Impulse Tester
MIG2412SPD
The MIG2412SPD is a impulse tester for testing SPD (Surge Protection Devices) in accordance with IEC 61643-1 and VDE 0675. Up to maximum 24kV/12kA making it suitable for testing Class I to III or in accordance with VDE Class A,C, D. The MIG2412SPD is a hybrid generator with a voltage wave shape 1,2/50 ìs at "no load" and a current wave form 8/20 ìs at short circuit for testing Class III (D) SPD connected to power line.
-
product
Wire And Cable
Chengdu Mengsheng Electronics Co., Ltd.
We provide a variety of wire and cable products, including insulated wires, power cords, stranded wires, solid wires, wiring harnesses and connectors. Our products are widely used in security, medical, communications, instrumentation, medical, home appliances, auto parts, military, aerospace and other industries. Our products strictly comply with the product certification standards of countries and regions such as UL in the United States, VDE in Germany, CE in the European Union, and BS in the United Kingdom.
-
product
Standard Gain Horn Antenna
SAS-586
This Standard Gain Horn Antenna will provide reliable, repeatable measurements. An ideal solution and a standard workhorse of any EMC test house for compliance testing. Features: 12.4 GHz to 18 GHz, Individually Calibrated, FCC, MIL-STD, VDE and TEMPEST Testing.
-
product
KPG 24kV VLF Test Set
Kilovolt Prueftechnik Chemnitz GmbH
The portable cable test set KPG 24kV VLF is used for testing of medium voltage cables in accordance to the standards IEC 60502-2, CENELEC HD 620 & 621, DIN VDE 0276/620 & 621 and IEEE 400.Test is carried out with a low strain practice with VLF (very low frequency) test voltage of preferably 0.1Hz.VLF testing enables detection of damages of insulation within shortest test time.
-
product
IP code Testing
Educated Design & Development, Inc.
Complies with various IEC, EN, CE, VDE, UL & CSA requirementsUnit comes with NIST traceable / ISO 17025 accredited certificate of calibration.ED&D is ISO 17025 accredited by ACLASS, an ILAC Member. Measurement data and uncertainty data is available.Uses RTS-01 Rain Spray Head
-
product
PD Measuring System
TEM
Partial discharge test system for laboratory or on-site measurement according to VDE 0434, IEC 60270 and EN50178 consisting of:*Partial discharge meter TMG*High-voltage coupling capacitors for decoupling of the PD pulses*Partial discharge calibrator TPK for determining the correction factor in the PD test circuit
-
product
High Voltage
Accurate measurement of high voltages acc. to VDE 0432 und IEC 60060 in conjunction with a high voltage divider.For the measurement, the principle of capacitive or resistive divider is used, which can be selected in the peak voltage meter.
-
product
BSV Systems
In the medical field, electrical devices are used on which people's lives or healing processes depend. The highest demands are therefore placed on the devices required in the operating room or intensive care unit. Gustav Klein BSV systems guarantee an uninterrupted and safe power supply in accordance with VDE 0100 and ÖVE/ÖNORM E 8007.
-
product
Partial Discharge Meter
TMG
The partial discharge meter TMG was developed for Partial Discharge tests according to VDE 0434 and IEC 60270.
-
product
Peak Voltage Measurement
In high voltage measurement technology, the peak value, or the effective value, of the voltage is determined in accordance with VDE 0432 or IECV 60060. The peak voltage measuring device from MPS Mess- & Prüfsysteme GmbH can measure these two values in connection with a high voltage divider (capacitive or resistive). In the event of flashovers in the high-voltage circuit, this is indicated in the SMG.
-
product
[5kV AC/6kV DC] Hipot and Insulation Resistance Tester, Rise/Fall-Time Control Function Equipped
TOS5300 Series
The "TOS5300 Series" is a series of test instruments used in Hipot (withstanding voltage) tests and insulation resistance tests, two of the four tests regarded as necessary for ensuring the safety of electrical products. With an output of 5 kV/100 mA (AC) and 6 kV/10 mA (DC), the series can be used in Hipot (withstanding voltage) & insulation resistance testing of electronic equipment and electronic parts, based on the requirements of IEC, EN, UL, VDE, JIS, and other international safety standards and the Electrical Appliance and Material Safety Law. Also, the test voltage stability is improved with the adoption of a newly developed switching amplifier. Since the output voltage can be kept constant even when the AC line voltage or frequency changes, consistent testing can be performed, even when the power supply environment is in an unstable region. The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a new low-cost standard model that provides thorough operability, reliability and safety.
-
product
PCI Bus Analog Output Board, 8 Isolated Outputs, 14 Bit
APCI-3501-8
*8 analog output channels*Optical isolation 500 V*Settling time 30 µs typ.*14-bit resolution (13 bit for 0-10 V)*Output voltage: ±10 V, 0-10 V (switchable through software)*Output voltage after reset: 0 V*Each output channel has its own ground line (without optical isolation from the others)*Driver capacity: 5 mA/500 pF*Short-circuit protection, EMI filters*Noise neutralization of the PC supply*Creeping distance: 3.2 mm acc. to DIN VDE 0411-100*Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary*2 digital input channels, 24 V, isolated*2 digital output channels, 24 V, isolated
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.