Phasor Measurement Units
synced remote wave monitors measuring ac current and voltage on a power grid. Also known as: PMU
See Also: PMU, Smart Grid
-
Product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
-
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
Product
Electrical Clock Recovery
N1076B
-
The N1076B Electrical Clock Recovery provides standards-compliant clock recovery capability on electrical NRZ and PAM4 signals from 125 MBd up to 64 GBd
-
Product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
-
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
Product
High-Speed Precision SMU (100 FA, 60 V, 15 MSa/s)
PZ2121A
-
The Keysight PZ2121A is a high-speed precision source / measure unit (SMU) featuring best-in-industry narrow-pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices, integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
Product
High Precision Source Measure Unit (SMU) - Hybrid Compatible PXI, 100ks/S Programming/Measurement Speed
52400 series
-
Hybrid Compatible PXIFour quadrant operationHigh source/measurement resolution (multiple ranges)Low output noiseHigh programming/measurement speed (100k s/S) & slew rateOptional measurement logDIO bitsOutput profiling by hardware sequencerProgrammable output resistanceFloating & Guarding output16 Control Bandwidth SelectionMaster / Slave operationDriver with LabView/LabWindows & C/C# APISoftpanel GUI
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
-
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
-
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
21-Ch 6A-250VA 2-Bus Fault Insertion
YAV90077
-
21 channels 1 thread 6A 250V 2 Fault Insertion Buses Switching up to 250W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
PXI Single Bus 64-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-401
-
The Single Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
-
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
-
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
Precision Source / Measure Unit (2 Ch, 100 FA)
B2902B
-
The Keysight B2902B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
-
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Battery Fault Insertion Unit
-
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
PXI 30A Fault Insertion Switch 6-chan 2-bus
40-191-012
-
The 40-191-012 is a PXI fault insertion switch using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
-
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
-
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
-
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
Source Measure Units and LCR Meters
-
Source Measure Units are high-precision, high-accuracy DC instruments that can both source and simultaneously measure voltage and current. Additionally, LCR Meters can measure the inductance, capacitance, and resistance (LCR) of electronic equipment.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch
40-190B-001
-
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Source Measurement Unit
DPS16
-
The DPS16 offers high voltage DPS in a compact, 3U PXI form factor. The DPS16 supports 0V to +4V 0.3A or 0V to 12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 16 channel can be ganged to support high current driving.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
-
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
-
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
-
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
Product
Digital Source Capture Unit
DIO2
-
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
Product
test measurement unit
ITC59100 Rg/Qg
-
The ITC59100 Test Measurement Unit (TMU), which plugs into the ITC59000 Test Platform, performs gate charge (Qg) measurements that conform to MIL-STD-750C, Notice 2, Method 3471 and JEDEC Standard JESD24-2. In addition the ITC59100 TMU performs an internal gate resistance (Rg) test method that conforms to JEDEC Standard JESD24-11.
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
-
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
-
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
-
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
NVIDIA GPU And Intel® Xeon® AI Computing Platform For Autonomous Drive Applications
AVA-3510
-
The AVA-3510 Series is powered by an Intel® Xeon® E processor coupled with workstation-grade Intel®C246 chipset to support up to 64 GB ECC DDR4 memory. The system incorporates one 2.5" SSD 256G for easy installation as optional accessories for fast read/write performance.





























