Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
Fault Insertion Unit
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR058-F2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
Phasor Meter
633
-
Red Phase Instruments Australia Pty Ltd.
This instrument is designed to demonstrate the properties of phasors and real/imaginary number notation for electrical engineering students. This instrument gives the phase displacement and magnitude of the parameter under investigation. The unit has filters to eliminate harmonic distortion affecting phase angle measurement.
-
Product
Single Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-201
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch, N/O Through Relays
40-190B-402
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
6U VME COTS System, Sensor Interface Unit
SIU6
Sensor Interface Unit
NAI's SIU6 is a highly configurable rugged COTS system or subsystem ideally suited for military, industrial, and commercial applications that require high-density I/O, communication, Ethernet switching, and processing. The SIU6 leverages NAI field-proven, 6U VME boards to deliver off-the-shelf, SWaP-optimized COTS solutions that "Accelerate Your-Time-to-Mission."
-
Product
Timing Measurement Unit
TMM200
-
The TMM200 is a resource available for measuring such parameters as propagation delays, rise time, fall time and any other time-related parameter. Because of its wide input levels, the TMM200 is an instrument well suited to test both digital an analog devices.
-
Product
2 Channel IV Analyzer / Source Monitor Unit
E5263A
Source Measure Unit
Keysight E5262A and E5263A 2ch IV Analyzers are the low cost solution for current-voltage characterization. The E5262A and E5263A support two channels of SMUs (Source/Monitor Units) for voltage/current sourcing and voltage/current measurement with the best in the class current measurement performance as low as 5 pA. The Easy EXPERT group+ GUI based characterization software is furnished and available on your PC to support all the tasks required in the characterization from the measurement setup to the data analysis. Powerful integration of SMU's versatile measurement capabilities and GUI based characterization software makes the E5262A and E5263A the best solutions for characterization and evaluation of two or three terminal devices such as materials and active/passive components with uncompromised measurement reliability and efficiency.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
Battery Fault Insertion Unit
Fault Insertion Unit
The Battery Fault Insertion Unit (FIU) provides intelligent switching of cell-simulation channels for the Battery Simulator 1200. The switching capability enables simulation of open-circuit and short-to-rail fault conditions on any cell channel for the purposes of battery management system (BMS) testing. Additionally, a four-wire auxiliary input allows you to connect an external digital multimeter (DMM) instrument to any cell channel for very high-accuracy bypass current and cell voltage measurements. Each FIU provides 24 independently-programmable cell-switching channels for one or two 12-cell Battery Simulator 1200 units. Additional Battery Simulator 1200 and FIU instruments can extend functionality up to 120 series-connected cell channels.
-
Product
2-18GHz Instantaneous Frequency Measurement Unit
DR024-F2
-
Teledyne Defence & Space’s Instantaneous Frequency Measurement (IFM) module, also known as a Digital Frequency Discriminator (DFD), offers high speed frequency measurement across the full operating bandwidth.The IFM measures the frequency of RF signal present at its input and presents a result at its output as digital data. The RF input signal is conditioned by an RF amplifier that provides sufficient drive for the frequency resolving circuits. The raw video from the resolvers is digitised and processed into the required output format. There is additional timing and control circuitry which initiates the measurement process and provides handshake data to the host system processor.
-
Product
Dual Bus 36-Channel 2A PCI Fault Insertion Switch
50-190-202
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI Single Bus 74-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-301
Fault Insertion Unit
The Single Bus, 74 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
Source Measure Unit
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Source Measure Unit (SMU)
-
Source and Measurement Units (SMUs) are devices that generate voltages or currents and can measure them simultaneously using the integrated measurement units (VMU, CMU).
-
Product
INERTIAL MEASUREMENT UNIT
MS-IMU3020
-
The MS-IMU3020 delivers market leading price to performance in an ultra-compact aluminum package. The gyro bias instability of 0.9 /h and accelerometer bias instability of 9 g supply ample performance to support a range of applications from UAS navigation and control to pipeline inspection.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-194A-001-HI
Fault Insertion Unit
The 40-194A-001 is a 7-Channel PXI Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. As well as high current handling of 20A, very low currents can also be switched.
-
Product
Engine Vibration Measurement Unit
MS 1101
-
Used to check engine vibration level. The seismic transducer mounted on both engines. Used for the measurement of vibration levels for various engine rpm. Used for the measurement of amplitude on each frequency component
-
Product
4x 3U OpenVPX MOSA Remote Interface Unit
SIU34-RIUVARM-01
Remote Interface Unit
SIU34-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RUI) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
Product
PXI 10A Fault Insertion Switch 10-Chan 1-Bus
40-199-001
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
3U OpenVPX Sensor Interface Unit - SIU36
SIU36
Sensor Interface Unit
The SIU36 is a highly configurable rugged system or subsystem ideally suited to support a multitude of Mil-Aero applications that require high-density I/O, communications, Ethernet switching and processing. The SIU36 leverages NAI’s 3U boards to deliver off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
Integrated AI-ADAS ECU And Cameras For Large Commercial Vehicle
ADM-TJ30
Electronic Control Unit
The integrated AI-ADAS ECU is connected to 8 cameras and powered by the vision-AI algorithm. It can detect and classify different kinds of vehicles/ pedestrians/ two-wheeler riders/ lane marking and other objects to perform multiple ADAS functions.
-
Product
Pulsed Source Measure Unit
-
The SpikeSafe SMU is a precision pulsed source measure unit that precisely sources pulsed current and simultaneously digitizes voltage. Optimized for precise and repeatable high-power LED and laser testing, SpikeSafe™ SMU (Source Measure Unit) current sources deliver precise pulsing with low microsecond rise times, low-jitter triggering and integrated digitizer for more accurate and repeatable high-power LED and laser testing.
-
Product
Fixed Units
-
A task type that keeps the assigned resources' percentage of time (availability) constant, even if the duration or total work required for the task changes.
-
Product
DFB Laser Source Module
LaserPXIe 1200 Series
Source Measure Unit
The LaserPXIe 1200 Series is a highly customizable DFB laser source available in a wide range of wavelengths and powers.
-
Product
PXI/PXIe Fault Insertion Switch, 64-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-112
Fault Insertion Unit
The 40-190C-112 (PXI) and 42-190C-112 (PXIe) are fault insertion switches with 64 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Compression Unit
BK1611
-
The BaKo BK1611 is a Compression Unit that uses a real time feedback loop to create a frequency sweep with constant level output. This would normally be used for either research or for calibration rather than product line testing and is useful because of its extreme stability. The BK1611 is not a dedicated system so it can be integrated into a variety of systems to be used for microphones, speakers or vibration motors.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.