Magnetic Field
an force around magnets, electric current and atomic orbits.
See Also: Magnetic, Magnetic Test, Magnetic Head, Magnetic Susceptibility, Magnetic Flux, Magnetic Stripe, Magnetic Permeability, H-field, Magnetic Field Mapping, Magnetic Field Meters, Magnetic Field Probes, Magnetic Field Sensors, Magnetic Field Test, Helmholtz Coils
-
Product
Shielding Effectiveness/ Conductivity Test
EM-2107A | 30 MHz – 1.5 GHz
-
The EM-2107A is a standard test fixture for evaluation of the electromagnetic shielding effectiveness of planar material. The fixture is an enlarged section of coaxial transmission line and complies fully with the requirements of ASTM test method D4935-1. The measured data relates to the shielding effectiveness due to a plane wave (far field EM wave) from which near field values for magnetic and electric fields may be inferred. The EM-2107A is provided with a reference standard test specimen, a dynamic range specimen. Dynamic range of greater than 80dB is achievable, although the cables and other test system components usually establishes the limiting factors.
-
Product
H/E fieldmeter
ESM-100
-
The 3D H/E fieldmeter ESM-100 is a patented, unique hand held measuring instrument. It can easily measure electric and magnetic alternating fields simultaneously, independent of their direction, and at one point. With this piece of equipment it is possible for anybody, to carry out quick, professional and error-free measurements, right from the beginning
-
Product
Digital Gauss Meter
-
STAR TRACE SOLUTIONS PVT. LTD.
Digital Gauss meters are hand held devices which are used to measure D.C magnetic field using Hall Probes. The Gauss meter is available in two different ranges and helps in quick calibration. As the Digital Gauss meter is easy and simple to handle it is extensively used in industries which require measurement of magnetic field.
-
Product
Digital Teslameters - Gaussmeter
-
Group3 are leaders in the innovation, design and manufacture of scientific instruments for magnetic field measurement solutions with ‘superior’ accuracy. With over 40 years'' experience Group3 match solutions to specifications and provide confidence with a reputation in precision, quality, reliability, accuracy and durability.
-
Product
Magnet Tester
-
The Magnet Tester invented by JUNG locates magnetic fields and notify it with its integrated lamp: compact, simple and fast!Easily check switch conditions with zero set-up time and no need to halt operations. The magnetic field test stylus is an indispensable tool for countless companies and toolboxes. Its light-function also makes it as an ideal flashlight.
-
Product
4 Port Devices
-
Four port devices can be realized by joining two 3 port devices via the appropriate ports. As system performance requirements become more demanding, new design approaches must be adopted. These include Faraday rotation devices and phase shift circulators. The bandwidth and isolation limitations of 3 port devices are overcome through a distributed architecture that enables more ferrite material to be incorporated into the transmission path, thereby achieving an increase in the biasing magnetic field. Phase shift circulators can be designed to handle higher RF power than 3-port devices.
-
Product
Scanning Probe Microscopy
-
SPECS Surface Nano Analysis GmbH
As Scanning Probe Microscopy (SPM) is a key tool for nanotechnology, SPECS offers dedicated solutions for highly demanding requirements.In UHV, strong emphasis lies on spectroscopic methods such as scanning tunneling spectroscopy and inelastic tunneling spectroscopy as well as single atom and molecule manipulation. With the invention of a Joule-Thomson cryostat by Prof. Wulf Wulfhekel, SPECS now offers the JT-STM , operating sample and sensors in thermal equilibrium below 1K with optional high magnetic field.
-
Product
Micro probes 1 MHz up to 1 GHz
MFA 02 set
-
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
Product
Hall Effect Speed Sensors
-
SPECTEC Innovative Sensor Solutions
SPECTEC zero speed Hall effect gear tooth sensors are used in industrial applications to determine shaft or gear speed or direction by detecting fluctuations in the magnetic field. The Hall effect technology fulfills a wide array of applications due to a Hall effect sensor's ability to detect zero speed and the quadrature sensor's ability to detect direction change. The Hall effect gear tooth sensor's digital output is easily read by computers, motion control devices, position monitors and digital to analog converters. Intrinsically Safe zero speed sensors are available for various applications.
-
Product
MagTest System
-
A System to generate magnetic fields and to perform tests regarding the susceptibility against magnetic fields.
-
Product
Fluxmeter
480
-
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
Product
Magnetoresistive Milligauss Meter
MR3
-
The MR3 Magnetoresistive Milligauss Meter measures and displays the three vectorcomponents (X, Y, Z) as well as the magnitude (M) of the static magnetic field. Update is two times per second. The three sensors are in a 25 mm (1") cube at the end of a flexible 100 cm (40") cable. It can be powered by 4 AA batteries (included) or a Worldwide AC adaptor (included). It can collect and store data (X, Y, Z and M) for later download or stream data live via USB connector. Both the instantaneous values of X, Y, Z and M, and their peak values, are displayed on the meter screen. "Peak" values are the highest values seen since the peak reset button was pressed. Maximum error of sensitivity is +/- 0.5 % of the reading, and the maximum error of the offset is +/- 0.50 milligauss. Range is +/- 1999.99 milligauss with resolution 0.01 milligauss (or 1 nT) over the full range, displayed simultaneously for X, Y, Z and M.
-
Product
Line Mounted Fault Indicator
LineTroll 110Eμ
-
Linetroll 110E contains magnetic and electric field sensors surveying line current and line voltage. The magnetic sensor automatically adapts to line current, detecting preset current increases. The electric field sensor is monitoring the presence of line voltage. The sensor signals are processed and compared with user set alarm criterias.
-
Product
L.V.D.T Products
-
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
Product
Magnetic Field Sensor
-
Vernier Software & Technology, LLC
The Magnetic Field Sensor can be used to study the field around permanent magnets, coils, and electrical devices. It features a rotating sensor tip to measure both transverse and longitudinal magnetic fields.
-
Product
MEMS Magnetic Sensor Test
-
Cohu offers a big variety of magnetic test solutions applying magnetic field in all three dimensions. Depending on the requirements we can integrate coils with and without magnetic core, single- or Helmholtz coils, as well as permanent magnets, static and rotating.
-
Product
Magnetic Field Press Device
-
Sometimes, magnetic application technology that can achieve results that push the limits of your products. Magnet-related equipment plays an important role in various fields such as electronics, metals, and physics.
-
Product
Tesla Meter
GX-100/GX-200
-
It can measure tiny magnetic field from 0.01mT. Both AC and DC can be measured without select.
-
Product
Fluxmeter
Model 2130
-
The Model 2130 Fluxmeter is a fully featured, high-end Fluxmeter based measurement system. It is a compact instrument with high accuracy, automatic drift correction, microprocessor control, and twelve measurement ranges to allow the operator to configure the meter for maximum resolution and accuracy. The Model 2130 is capable of measuring (DC), alternating (AC), or pulsed magnetic fields. Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy to use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements.
-
Product
Multi-Sensor
Panda
-
The NeuLog Panda multi-sensor can be used for any science experiment which utilizes Room Temperature, Light, Barometric pressure, Altitude, Sound, Relative Humidity, Dew-Point, Magnetic Field and G-Acceleration readings.Panda is used for environmental data collection and other experiments in Natural Science, Biology, Physics and Chemistry. It is specially designed for primary school level.The multi-sensor comes pre-calibrated so you can start experimentation right out of the box
-
Product
Digital Geological Data Collector
TECTRONIC
-
F. W. Breithaupt & Sohn GmbH & Co.KG
*Measurement and reading of azimuth of dip and angle of dip in one single operation (according to Clar method)*LCD display and memory for approx. 4.000 measurements*RS232 interface*Display indication 1° (360°, 400g, 6400– or 6300– selectable)*Many additional functions like measurement of magnetic field intensity)*Circular spirit level*Accessories upon request (Software, tripods, battery packs, …)
-
Product
Speed Sensors
-
DHE (Differential Hall Effect) sensors give an output when subjected to a changing magnetic field. The field is set up by a magnet inside the sensor body and changes when ferromagnetic teeth are passed beneath the sensor (no magnets are required in the target). To improve noise resistance, the sensor has two Hall effect elements and only responds to changes in magnetic field strength corresponding to tooth passing frequencies above 15Hz. As each tooth passes the sensor, the digital state of the output changes.
-
Product
Triaxial ELF Magnetic Field Meter
SK-8301
-
Accurate measurement by- True RMS- Built-in XYZ triaxial sensorFor 40Hz to 1kHz magnetic field measurement.uT and mG are selectable.MAX/MIN and Average measurements.Compact and easy-to-carry.Easy operation by only 3-keys.
-
Product
3-AXIS DIGITAL AC GAUSSMETER: 1-200 kHz
IDR-200
-
Integrity Design and Reseach Corp.
Typical Applications include checking the frequencies and magnetic fields (BW: 1 kHz -200 kHz) produced by equipments such as computer monitors, television sets, video display terminals, induction heaters, industrial, Radar, scientific/medical equipment, walk-through/hand-held detectors and ground wave energy network; etc. For more information about VLF magnetic fields and the VLF gaussmeter , see the paper titled "Very-low-frequency electromagnetic field detector with data acquisition," IEEE Trans. Instrum. Meas.,vol. 58, no. 1, pp. 129-140, Dec. 2008. by S. Hanna.
-
Product
Antenna, Loop
EM-6879 | 10 KHz – 30 MHz
-
The EM-6879 Loop Antenna is used for magnetic field measurements over the frequency range of 10 kHz to 30 MHz. The EM-6879 is designed for use with any 50 ohm Receiver System. The antenna has a balanced Faraday shield that reduces its response to electric fields to a vanishingly small amount so that it can produce a practically pure magnetic field response.
-
Product
Loop Antennas
-
A.H. Systems' designs, manufactures and delivers high performance Loop Antennas for a wide range of magnetic field testing. Whether used in a set to measure shielding effectiveness per MIL-STD 285 and NSA 65-6 or individually to satisfy specific requirements,
-
Product
Reference Magnets
Series MT
-
The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.
-
Product
Vector Magnetometer
FVM400
-
Macintyre Electronic Design Associa
The FVM400 uses fluxgate technology to measure the three vector components of the magnetic field. The fluxgate sensors are packaged in a 1" square by 4" long probe that is connected to the handheld electronics unit by a modular telephone cord. The sensor can be located up to 100 feet from the electronics unit.
-
Product
Modeling Capacitors, Inductors, Insulators, Coils, Motors, and Sensors
AC/DC Module
-
The AC/DC Module is used for simulating electric, magnetic, and electromagnetic fields in static and low-frequency applications. Typical applications include capacitors, inductors, insulators, coils, motors, actuators, and sensors, with dedicated tools for extracting parameters such as resistance, capacitance, inductance, impedance, force, and torque.
-
Product
Magnetometers
-
The strength of magnetic fields can be determined with a magnetometer. Regardless of whether in the private sector or in the work environment, the increasing use of technology and networking also increases the exposure to magnetic and electromagnetic radiation. This radiation can have a negative effect on living beings, but also on sensitive electronic devices. Many effects are so unspecific that radiation is often not recognized as the cause. With a magnetometer you can measure how strong the radiation is at your sleeping place, in the kitchen in front of the microwave or induction stove or at your workplace. The location of sensitive electronic devices such as a precision balance can be examined with the magnetometer. The extent to which the radiation intensity increases or decreases with distance can be determined by positioning the magnetometer at various distances from the radiation source.