Fault Indicators
See Also: Indicators, Angle Position Indicators, Loop Indicators, Voltage Indicators
-
Product
RS485 Remote Display Indicator
CS1-8
-
CS1-8 has been designed for remote display by RS485 (Modbus RTU Mode) interface.
-
Product
Ground Fault Detectors
-
STB Electrical Test Equipment, Inc
STB's convenient Ground Fault Detectors may be operated with one hand and are ideal for preventative maintenance. Ground Fault Detectors indicate ground faults and electrical leakage while equipment is in operation.
-
Product
Voyager Intermittent Fault Detection Tester
-
This family of testers is available as the portable VIFD™ tester (previously called the Ncompass-Voyager) with 128, 256 or 512 test points, and it is available as a 19” rack-mount system – the IFD & Isolation System (IFDIS™) – with thousands of test points. Testers are available from Copernicus Technology for purchase or lease. Alternatively we can provide the full test service for you and we also provide all the corresponding test accessories listed under the Test Equipment menu button.
-
Product
FiberScout | Fault Identifier & Singlemode Fibre Length Tester
TS21
-
The TS21 Fiber Scout was designed and developed by Yamasaki as a cost effective and simple solution for identifying faults and testing the length of singlemode fibers. This lightweight, rugged, dustproof and water resistant piece of test equipment can list up to 8 results at one time and has three brilliant functions.
-
Product
Motor&Phase Rotation Indicator
-
Precision Mastech Enterprises Co.
A diagnostic tool used to identify the sequence or \(A,B,C\)) of a 3-phase power supply and determine the proper direction of rotation for 3-phase motors.
-
Product
PXI Fault Insertion Matrix Modules
-
All of our fault insertion matrices feature a breakout arrangement that allows faults to be attached to the sensor lines via the Y axis. This includes the breaking of a connection or the adding of a series defect – all of which can simulate connectivity problems in the system. The three pin breakout versions allow the connection to be swapped for a “bad” sensor simulation.
-
Product
Primary Cable Fault Locating
Directional Impulse Detector
-
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
Product
Mobile Cable Fault Location System
BAUR Syscompact 4000
-
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
Product
Mini AC Leakage Current Clamp Indicator
MLD-18
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・The LED will blink when detection leakage current exceeds AC 15mA.・Supports ELB with high-speed detection of 20ms.・The operating period is about one month, which is suitable for detecting intermittent leakage current.
-
Product
Lipo Battery Power Level Tester & Alarm to Indicate Low Power
#52023
-
Can be used for 7.4V (2S pack)and 11.1V (3S pack).Red LED will flash when cell is below 3.3V and an Alarm will sound when cell is below 3.0V indicating the Lipo Battery pack should be recharged.
-
Product
Electrical Fault Detector
-
Our product range includes a wide range of Electrical Fault Detector and 0.36W Electric Fault Detector.
-
Product
50-Pin DIN-Rail Wiring Board W/ LED Indicators
ADAM-3951
-
Low-cost DIN-rail mounting wiring terminal module for PCI-1752/1754/1756 with 50-pin SCSI female connectorScrew-clamp terminal blocks allow easy and reliable connectionsEach LED indicates its current bi-directional I/O logic status with either green or red lightCase dimensions (W x L x H): 77.5 x 179.5 x 41.5 mm (3.1" x 7.1" x 1.6")To Be Used With PCI-1752U, PCI-1754, PCI-1756
-
Product
PXI-8511, 1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module
780686-01
CAN Interface
1‑ or 2-Port, Low-Speed/Fault Tolerant PXI CAN Interface Module—The PXI‑8511 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The PXI‑8511 excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. The NI‑XNET device-driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimize message latency and freeing host processor time for processing complex models and applications.
-
Product
USB-8501, 2-Port, Low-Speed/Fault Tolerant, USB CAN Interface Device
786307-01
CAN Interface
The USB-8501 is a low-speed controller area network (CAN) interface for developing applications with the NI‑XNET driver. The USB‑8501 is powered over the USB bus and does not require external power. It excels in applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals such as bus monitoring, automation control, and more. The NI‑XNET device‑driven DMA engine enables the onboard processor to move CAN frames and signals between the interface and the user program without CPU interrupts, minimizing message latency and freeing host processor time for processing complex applications. The USB‑8501 is available with a three‑pin COMBICON synchronization connector for triggering and synchronizing the internal hardware timebase with other devices.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
Cable Fault Locator
TW3304N
-
Techwin(China) Industry Co., Ltd
The Perfect Handhold Tester Series Cable Fault Locator TW3304N is the most portable test instrument in the industry. It adopts the OTDR technical principles and integrates the powerful analysis software, which enables the TW3304N fiber ranger detect fiber faults location more accurate and easy.
-
Product
Fault Locating
-
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
Product
Cable Fault Locators
-
Cable Fault Locator is a device used for short circuit faults, cable cuts, resistive faults, intermittent faults, and sheath faults. Fiberinthebox supply cable fault locator for power cable, optical fiberal cable, etc. Fault Location in Power Cable is designed to locate cable faults, pinpointing the fault location, route tracing, cable identification, voltage withstand test and cable information management. It can locate all kinds of cable faults for all voltage level cables, including open circuit, short circuit, low insulation, high insulation and flashover faults, etc. Most power cables were buried underground, invisible, and out of reach, with modern new power cable fault locater, it can find the fault point quickly, solve problems immediately and restore power supply.
-
Product
Temperature Indicator
TICT
-
The LogTag® TICT is a low cost disposable electronic temperature indicator for use in monitoring temperature & time statistics in transport applications of up to 45 days duration. The LogTag® TICT can monitor and record statistics against four factory pre-set temperature limits for up to 45 days, displaying ‘OK’ if environmental conditions remain within limits. If temperatures exceed two high temperature alarm limits or go below two low temperature alarm limits, the LCD shows a ‘REJECT’ alert, indicating the goods require further checking.
-
Product
5mA High Accuracy Ground Fault Detector
HA-GFD
-
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
Product
Customized Indicator Cluster Gauge Kits
169CL-series
-
Over the past 40 years, Sigma Tek has custom designed and manufactured reliable, proven instruments for virtually every type of aircraft that flies. This includes precision modular instrumentation configured to customer's exact specifications. Cluster modules measure 1.44" square, and can be arranged in almost any combination for optimum panel utilization. Individual modules are easily removed for calibration and service.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
Digital Indicators
-
NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.
-
Product
PXI Fault Insertion / Signal Insertion Switch Modules
Switch Module
Pickering's PXI Fault Insertion / Signal Insertion Switch Modules feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system. Two switching topologies are available: *Single signal paths with series switches and switches to connect to one or more fault buses*Pairs of signals with series switches, shorting switches between the signal pairs and switches to connect either signal to an external fault input.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Freeze Temperature Indicator
TICT iS0°Tag®
-
The TICT iS0°Tag® can be used to monitor the temperature of any freeze-sensitive product such as vaccine, food, or specialty chemicals for up to 3 years.
-
Product
Travelling Wave Fault Location Test Kit
PH Series
-
PH series travelling waveform fault locating relay/equipment test set is a new device to meet the needs of testing and verification for travelling wave fault location equipment and protection relay with TWFL function.
-
Product
Level Indicators
-
4B has a wide range of radio frequency (RF), rotary paddle and capacitance point level indicators for detecting high, intermediate, or low levels of liquids, powders and free flowing granular solids stored in tanks, bins, silos or other containers. Certain units can also be used as plug or choke detectors in chutes, conveyors and elevator legs.
-
Product
Economic Type Strain Gauge/Load Cell Indicator
CS1-SG
-
CS1-SG economic type strain gauge/load cell indicator is equipped with high accuracy measurement, display and communication of DC signal 0~1.0/~4.0mV or 0~10.0/~40.0mV.It supports field calibration, and It can calibrate with sensor (load cell/strain gauge) according to actual needs.It is able to select one from these three functions, 1 relay output, 1 analogue output or 1 RS-485 (Modbus RTU Mode) interface; they provides many functions such as control, alarm, re-transmission, and communication.
-
Product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 8 Channel
50-200-008
Fault Insertion Unit
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.