ATE
ATE systems are used to test semiconductor devices, printed circuit boards, and electronic systems during manufacturing. AI prompted RL created', prevails upon the UUT to demonstrate It's fulfillment of test requirements.
See Also: Automatic Test Equipment, ATS, Functional ATE, Combinational ATE, Semiconductor Test, PXI Switching, PXI Chassis, PXI Matrix, Automated Test Equipment, Automated Test Systems
-
Product
PXI Very High Density Mux 24 Ch 8 Pole
40-670A-022-24/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
LXI High Density 40x20 Matrix
60-590-001
Matrix Switch Module
The 60-590 is a high-density single pole LXI matrix available in 40x20 or 40x40 configurations and is suitable for signal routing in large ATE systems.
-
Product
PXI 4 Banks of 40 Channel 1 Pole MUX
40-615-022-4/40/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Receiver, G18, 18 Module, Slide Mounting (slide Kit Required)
310120141
Receiver
This lightweight and rugged 18 module receiver will accommodate larger ATE chassis’ (PXI, VXI, SCXI). It allows space for up to an 18-slot PXI chassis. This receiver is designed to work with a slide kit and includes a mounting plate, mounting flanges and instrument bracket. A slide kit is not included and required for use.
-
Product
Programmable Step Attenuator, DC to 40 GHz, 0 to 90 dB, 10 dB Steps
84906L
Attenuator
The Keysight 84906L programmable step attenuator offers coaxial measurements to 40 GHz in a compact, rugged design. It offers repeatability of better than 0.03 dB, excellent life greater than 5 million switching cycles per section) and an attenuation range of 0 to 90 dB in 10-dB steps. This latest design evolution sets new standards for size and performance. High attenuation accuracy and low SWR are achieved through the use of miniature thin-film attenuation cards composed of high-stability tantalum nitride film of saphire substrate. Insertion loss is outstanding, with with only 2.4 dB of loss at 40 GHz. The compact size of the unit, 35% smaller than the Keysight 8495/7 (26.5 GHz) family, allows for easy integration into instruments and ATE systems.
-
Product
Open Test Platform for High Performance Automotive Applications
TSVP
Test Platform
The R&S®TSVP family of products is an open test platform from Rohde & Schwarz ideal for high performance automated test equipment (ATE) applications. The chassis contains a mechanical frame, digital backplane, analog backplane, mains switching and filtering, power supply and diagnostic extensions. A highlight is the analog bus for routing measurement signals between different slots without additional external wiring.
-
Product
LXI HD Dual 16x64 2A Matrix With BIRST
60-552-029
Matrix Switch Module
A high-density single pole LXI matrix module capable of switching up to 300VDC/250VAC, 2A (60W max). The use of high-quality electro-mechanical relays offers high switching confidence for signal routing in large ATE systems.
-
Product
PXI/PXIe Very High Density Multiplexer, 99-Channel, 2-Pole
40-675B-002-99/2
Multiplexer Module
The 40-675B-002-99/2 (PXI) and the 42-675B-002-99/2 (PXIe) are 99-channel, 2-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
LXI Low Thermal EMF Matrix 1-pole 56x33
60-510-001
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
PXI 8 Slot BRIC 88x16 1-Pole (8 sub-cards)
40-562A-121-88X16
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
Aerospace & Defense ATE Systems and Services
-
TE solution design, development, and integrationMeasurement / Test Process analysis and consultationEasy-to-use software interfaces for Engineers and UsersFactory automation for test processesAll major instrument brands available & supported
-
Product
PXI 8 Slot BRIC 414x8 1-Pole (9 sub-cards)
40-560A-121-414X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8 slot PXI sizes to suit all high-performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 2 Amp MUX, Dual 16-Channel 1-Pole
40-635-105
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI Dual 4 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated
40-882-002
Multiplexer Module
This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
Product
Modular Power
RFP Controller
-
AMETEK Programmable Power, Inc.
ReFlex Power™ is a high density, modular programmable power system providing DC, AC and electronic load assets all under control of a single controller. It provides a reconfigurable, flexible platform ideal for ATE and production test environments where RFP™ can provide programmable stimulus and bias power as well as programmable loads for the device(s) under test. The EIA 4U high RFP™ mainframe can hold up to 12 single-slot modules or combinations of single, dual and triple slot wide modules to configure (or reconfigure) the system for the particular requirements at hand. The mainframe can support up to 6 kW of output power.
-
Product
LXI High Density 320x4 Matrix - 60-551-025
60-551-025
Matrix Switch Module
High-density single pole matrix module capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high-quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Product
PXI 8 Slot BRIC 30x32 1-Pole (6 sub-cards)
40-562A-121-30X32
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI Dual 12x4 1-Pole Matrix Module, Screened
40-511-021-S
Matrix Switch Module
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
Product
PXI Single 24x8 Matrix, 2 Pole Switching
40-521-022
Matrix Switch Module
Typical applications for this high density matrix include signal routing in Functional ATE and data acquisitionsystems. These PXI matrix cards are constructed using high reliability rutheniumelectro-plated reed relays, offering >10e8 operations to give maximum switchingconfidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, 7 PXI modules will form a 168x8 Matrix, a total of 1344 crosspoints in a 7-slot PXI Chassis. All 40-521 series modules are fitted with reed relays (ruthenium sputtered type), these offer very long life with good low level switching performance and excellent contact resistance stability.Spare Reed Relays are built onto the circuit board to facilitate easy maintenance with minimum downtime.
-
Product
PXI 2 Amp Multiplexer, Dual 8-Channel, 2-Pole
40-635A-106
Multiplexer Module
The 40-635A-106 is a dual 8-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI High Density Multiplexer, 4-Bank, 20-Channel, 2-Pole
40-615A-008
Multiplexer Module
The 40-615A-008 is a 4-bank, 20-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
Coax Switches
-
With up to DC - 53GHz bandwidth, low insertion loss, high isolation, and high repeatability, these switches are used to support SATCOM, aviation, military and commercial telecommunications, medical imaging, and ATE systems.
-
Product
PXI Very High Density Multiplexer, 24-Channel, 8-pole
40-670C-022-24/8
Multiplexer Module
The 40-670C-022-24/8 is a 24-channel, 8-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI MUX 1 Bank, 64 Channel Screened 1 Pole
40-610-021-S-1/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
DC Power Module, 35V, 1.5A, 50W
N6734B
Power Module
The Keysight N6734B is a 52.5 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
Product
PXI/PXIe RF Multiplexer, Triple 4-Channel, Terminated, 8GHz, 50Ω, SMA
42-882B-003
Multiplexer Module
This multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40/42-882B MUX ideal for ATE systems requiring frequent and fast operating RF switching.
-
Product
Advanced Power System - DC Power Supply, 80 V, 12.5 A, 1000 W
N6954A
DC Power Supply
The N6954A is designed for automated test equipment (ATE) applications where high performance is critical.
-
Product
DC-18GHz Coaxial Multiplexer
MS2102A
-
Universal Switching Corporation
Enhancing ATE systems and satellite monitoring, the System MS2102A is a compact high-performance modular switch multiplexer specifically designed for routing any coaxial signal within the DC-18GHz bandpass. Configurations are available from 1x10 to 1x100 (or dual 1x50), and custom configurations are a simple to accomplish. The 100 ports are normally open (reflective) when not routed. For a self-terminating version of this unit, please see Model MS2103A.
-
Product
PXI Single 46x4 Matrix, 1 Pole Switching
40-524-021
Matrix Switch Module
Medium density PXI dual 46x4, 1-pole matrix - it is also available inreed relay formats of 2-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
Advanced Power System - DC Power Supply, 60 V, 33 A, 2000 W
N6973A
DC Power Supply
The N6973A is designed for automated test equipment (ATE) applications where high performance is critical.