Loop
See Also: Current Loops, HIL, Loop Testers
-
Product
Connector and Breakout Box
ES4640
-
The ES4640 Connector Box offers a standardized wiring and connectivity for HiL testing systems in the powertrain domain. Its front panel provides connectors for the ECU, CAN bus communication, on-board diagnostics, and LEDs for ignition and injectors. Its rear panel connects loads, failure simulation, and other components. Sample applications of the ES4640 are closed loop HiL systems for 8 cylinder gasoline and diesel engine ECUs.
-
Product
Shared Memory Network PCI Express Interface
PCIe-SMN
-
Avionics Interface Technologies
2.125 Gbps Optical loop network - Single-mode and Multi-mode optical interfaces supported - Up to 256 Shared Memory Network nodes supported - Up to 200 MByte/sec sustained data rates - Maximum 500 nS latency between nodesNetwork interrupts supported - PCIe 2.0 (x4) CompliantSoftware Drivers available for Windows, Linux, LabVIEW Real-Time, and VxWorks
-
Product
3U OpenVPX SOSA™-aligned PWM Servo Motor Drive
68PW1
Servo Motor Drive
The 68PW1 is a 3U OpenVPX SOSA™-aligned (basis, Snapshot 2) single-axis PWM servo motor drive that can be configured with closed loop feedback measurement options including Hall, Resolver/Synchro or Encoder. The PWM drive provides programmable PWM output drive (up to 65 V @ 10 A continuous) from a single +28 VDC input source. Ideally suited for rugged Mil-Aero applications, the 68PW1 delivers off-the-shelf solutions that accelerate deployment of SWaP-optimized systems in air, land and sea applications.
-
Product
Open Loop Current Sensor
C03 30A
-
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
Product
NI-9266 , 8-Channel C Series Current Output Module
785046-01
Current Output Module
8-Channel C Series Current Output Module - The NI‑9266 is ideal for interfacing and controlling industrial current-driven actuators. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9266 includes channel‑to‑earth ground isolation for safety and noise immunity.
-
Product
1.25GS/s 16Bit 1GS Mem 2CH 4 Markers Arbitrary Waveform Generator
P1282B
Waveform Generator
The Proteus P1282B, is a 1.25GS/s, dual channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P1282B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
Function Modules
-
NAI offers over 70 smart, field-proven function modules covering a wide variety of I/O, Measurement and Simulation, Communications, Ethernet switch and SBC functions. With Off-the-shelf development and quick integration speed, NAI's function modules provide the ability to reconfigure and respond to changing design specifications reducing NRE charges and offering obsolescence protection all with unmatched flexibility with countless hardware & software combinations. Each smart function module has dedicated FPGAs on-board with memory map-based configurability, programmable PID loop support and health monitoring via Built-In-Test. A single API provides programmability across all leading to a more I/O-intensive, distributed, smart and total cost-effective mission system.
-
Product
Load Cell Transmitter
MODEL SST-HV
-
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
Product
PCI Express 8 Reed Relay Output
8012e
-
The 8012e Low Profile PCI Express digital interface provides eight optically isolated inputs and eight Reed relay outputs (SPST). The isolated inputs are non-polarized and rated for 3-30 VDC. Optical isolation protects the PC and other sensitive equipment from the voltage spikes and ground loop currents that are common to industrial environments.
-
Product
PXIe-7856, Kintex-7 160T FPGA, 1 MS/s PXI Multifunction Reconfigurable I/O Module
784145-01
Multifunction Reconfigurable I/O
Kintex-7 160T FPGA, 1 MS/s PXI Multifunction Reconfigurable I/O Module—The PXIe‑7856 features a user-programmable FPGA for high-performance onboard processing and direct control over I/O signals to ensure complete flexibility of system timing and synchronization. You can customize these devices with the LabVIEW FPGA Module to develop applications requiring precise timing and control such as hardware‑in‑the‑loop testing, custom protocol communication, sensor simulation, and high-speed control. The PXIe‑7856 features a dedicated A/D converter (ADC) per channel for independent timing and triggering. This design offers specialized functionality such as multirate sampling and individual channel triggering, which are outside the capabilities of typical data acquisition hardware. The PXIe‑7856 also includes peer‑to‑peer streaming for direct data transfer to other PXI Express modules.
-
Product
Phase Detectors
-
Holzworth Instrumentation, Inc.
These components are targeted for use in phase noise measurement systems and ultra low phase noise phase lock loop designs.
-
Product
Signal Injectors
-
Ideal high performance, low noise compliment to your Circuit Sleuth Frequency Response Analyzer. An injection transformer is used to couple an excitation signal from a frequency source into the feedback loop of a control system. This allows loop gain and phase vs. frequency to be measured, with the loop closed, thus characterizing the stability of the system.
-
Product
Temperature Transmitter
T4111
-
Transducer is designed for temperature measurement at C or F by means of an externaltemperature probe with Pt1000 sensor. Measured temperature is converted to linearized unified signal 4-20 mA. Measured values are displayed on LCD display. It is possible to switch OFF theLCD at all. Current loop has two-wire connection and requires power from evaluation device.
-
Product
Toxic Gas Sensor
Model 100
-
Teledyne Gas & Flame Detection
Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a ¾ inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel. Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.
-
Product
VECTOR-GUN HANDHELD DIRECTION FINDING ANTENNA SYSTEM
HFDF
-
National RF's Type HFDF active directional antenna system consists of a high gain RF amplifier coupled to a tunable Faraday shielded loop antenna. Several loop antenna assemblies are available to provide coverage of frequencies in the HF and low VHF spectrum. Due to the nature of a Faraday shielded loop, the antenna exhibits a sharp null through the diametric center of the loop. This null is used to determine the direction of incoming radio signals or to locate electrical noise being radiated from some source. The internal high gain amplifier is used to compensate for the inherent inefficiency of the actual loop at the operating frequency. Overall, the system dynamic response is about +6 dB as compared to the dynamic response of a dipole. To aid in the direction finding process on strong signals, an internal 30 DB attenuator is provided. As the loop antenna presents a bi-directional response, tri-angulation may be required to eliminate the ambiguous signal direction. The line of site of the incoming signal is determined by listening for a signal null on the receiver or by watching the receiver’s S-meter.
-
Product
Material Science Laboratory Instruments
-
our material science laboratory instruments basically consists of four instruments first, young modulus apparatus which is used for determining the young modulus elasticity of a wire by stretching it. Then second is curie temperature kit which is used for determining the Curie Temperature. With the determination of dielectric constant of PZT material with Temperature variation. After that comes dielectric constant kit which is used for measuring the dielectric constant of solids and lastly our universal B-H Curve Tracer which is used for tracing the B-H loop which is very difficult and needs a good machinery for doing so.
-
Product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
Product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
-
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
Product
Multifunctional testers
MI 3152 EurotestXC
-
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
Product
Active Loop Antenna
AL-130R
-
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
Product
Control Systems Projects
-
Precision Development Consulting Inc
Fast Open Loop temperature control system, Batch CVD temperature control system, Single Wafer Temperature control system, Disk Drive Spindle Motor Control, Wafer Indexer Motor Control
-
Product
Loop-Powered Transmitters and Drivers
4-20mA
-
Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.
-
Product
32Ch Isolated Input Card
SET-1310
-
This card provides 32 optically isolated digital inputs. SET-1310 combines high-density IO with high isolation voltages and a wide input voltage range. It allows to break ground loops and protect your system from high-voltage spikes, but also to connect high voltage signals to standard logic level acquisition devices. The channel-to-channel isolation allows to connect signals from different DUTs to a single acquisition system without compromises.
-
Product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
-
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
Product
Signal Isolators & Converters
-
Devar current loop signal isolators reduce problems found in field measurements when signal transmitters or converters encounter both input and output signals that may be grounded. Current loop isolators eliminate these ground loops and are available as input loop powered or output loop powered instrumentation.
-
Product
Composite 1×24 Video Distribution Amplifier
VDA124RM-12
-
Video Distribution Amplifiers (sometimes called a video splitter – not to be confused with a video split screen controller such as our PXD510E split screen controller) are typically used for connecting a camera or other video source to several monitors that do not have “looping” inputs. In this situation, each monitor has a permanent 75 ohm termination. With two non-looping monitors connected together, the line would be double loaded and result in a dim picture on each monitor. Using a Video Distribution Amplifier will solve this problem by driving each monitor individually at 100%.
-
Product
Monitoring Loops
-
The Loop Sensor was designed to monitor the generated magnetic fields in radiated susceptibility tests.
-
Product
Alarms
-
Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.
-
Product
Single Channel Potentiostats
-
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
Product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
Analog Output Module
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.