Standard Transformers
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1F-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
The Industry Standard for Automated Network Protocol Validation
IxANVL
-
Keysight Network Applications and Security
With Ixia’s IxANVL (automated network validation library), you can quickly and effortlessly access a vast array of protocol libraries and utilities to validate protocol compliance and interoperability. Easy to use thanks to an enhanced GUI and flexible test-automation capabilities, IxANVL delivers a number of key advantages. By emulating large, multinode networks, it not only reduces costs—it also leads to more efficient testing and faster product-release times. And extensive and thorough automated testing increases your confidence in product quality.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2TB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard Helmholtz Coils
-
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Isolating Transformers
-
PeakTech Prüf- und Messtechnik GmbH
Peaktech Isolating Transformers
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1F
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1HC-4
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Potential Transformers
-
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
Product
Standard 0.81 (23.00) - 4.50 (128.00) Battery Probe
CP-059-026
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 57Full Travel (mm): 1.45Recommended Travel (mil): 40Recommended Travel (mm): 1.00Mechanical Life (no of cyles): 100,000Overall Length (mil): 221Overall Length (mm): 5.61
-
Product
Standard Voltage 9 Pin D-Type Cables - Connector to Unterminated for Pickering Products
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Standard VXI Module Shield Kits Without Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Same design described above but without the address switch opening.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-7
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50H-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
-
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Portable Single-Phase Energy Standard
PEWM-3C-1
-
The single-phase energy standard PEWM-3C-1-1 is used for a quick check on site of all types single-phase electricity meters – for active, reactive or apparent energy, electromechanical and electronic. The voltage and the current are measured at the same time. The current can be measured directly within 10A or 100A range or with current clamp to 100A. The current clamp is electronically compensated.
-
Product
Ultra Low Noise Disciplined Frequency 4220a Standard with Rubidium and OCXO Clean-Up Oscillator
-
Precise Time and Frequency, Inc.
The ptf 4220A is an Ultra Low Noise Disciplined Frequency Standard with rubidium and OCXO clean-up oscillator.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
O.E.M. Optical Standards
-
O.E.M. Optical Standards by Applied Image - Boston Scientific Checkerboard Array, Cognex Glass Calibration Plate Set
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
NanoLattice Pitch Standard for Mask Handling Tools (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25J-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Automated Resistance Standard
SmartResistor
-
The SmartResistor combines, into one transportable device, all the items needed to maintain resistance: a set of standard resistors, a controlled temperature bath, a low thermal emf scanner, and measurement data.
-
Product
Transformer Oil Dielectric Strength Testing
LS -JJ-II
-
Chongqing Lushun Scientific & Technological Development Co., Ltd.
1.The instrument has the function of automatic detection. 2.Tiny TPU-A panel printer is adopted for automatic printing out type insulating oil dielectric strength ATE is a full self-reacting device, which is developed according to the requirements in International IEC-156 and International GB507-86 "Insulating Oil Dielectric Strength Mensuration", combining the feedback opinions of all users .The instrument adopts singlechip as the leading part, and uses the method of "first setting and then testing". The whole process is controlled by automatic microcomputer. It is operated simply and used conveniently.
-
Product
Impedance Standards and Calibrators
-
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
Product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
-
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.