Bias Tees
-
Product
Bias Tees
-
A bias tee is a three-port network used for setting the DC bias point of some electronic components without disturbing other components. The bias tee is a diplexer.
-
Product
Bias Tees for Radio Amateurs
-
Bias Tee for remote power supply of preamplifiers and converters via the coaxial cable.
-
Product
Micro probes 1 MHz up to 1 GHz
MFA 02 set
-
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
Product
Master Oscillator Multiplexer
MOX Series
-
*Low phase noise OXCO *Interface between VSAT Modems and Frequency Converters *Robust housing is gasket sealed for weather resistance *OCXO iwth low G-sensitivity available *Single or dual multiplexer *Single or dual bias tee *Available in various OCXO frequencies: 10, 50, 100, 120 MHz
-
Product
Low Noise Pre-Amplifiers
-
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
Product
Bias Tees From 0.03 MHz To 85 GHz
-
Pulsar offers a large variety of bias tees that cover frequencies from DC to in both surface mount and connectorized packages. Many models are available with voltages up to 100 volts and currents up to 8 amps and custom requirements are welcomed. Options include higher voltage and current, higher RF input power and a choice of either an RF connector or a feedthrough connection for the DC input port.
-
Product
RF & Microwave Passive Components
-
SHF Communication Technologies AG
SHF’s microwave components are broadband devices suitable up to 110 GHz. Our SHF BIAS TEES are well known but perhaps a slight variation does suit your application even better. DIPLEXERS are bias tees with a certain bandwidth in the low frequency path to combine or separate high frequency and low frequency signals into or out of a single line. DC-FEEDERS are bias tees without the capacitor. Therefore, it provides slightly lower insertion loss in case it is connected to an AC-coupled device which already has a capacitor on its input. Based on our air line construction, these passive components provide resonance-free transmission over the entire operating range.
-
Product
High-Power Low-Loss Pulsed Bias Tees
MBT series
-
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
Product
Bias Tees
-
Mini-Circuits is your complete source for bias tees, handling up to 4 Amps DC and covering 100 kHz to 12 GHz!Rugged coaxial modelsTiny surface mount packages as small as 0.15 x 0.15 inExcellent isolation50 and 75 Ohm models
-
Product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
-
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
Product
Bias T's
-
Centric RF offers Coaxial Bias T's so that a DC voltage can be applied to the rf signal path. These Bias Tee's (aka bias t) currently are offered with sma and 2.92mm connectors. Bias T's are implemented by attaching a broadband inductor to the circuit trace, with the power rating of the bias tee being determined by the size of the inductor.
-
Product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX52
Frequency Extender
The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.
-
Product
Magic Tee
MHTXE
-
The MHTXE Magic Tee Hybrid Couplers for millimeter waves are matched power dividers for variety of applications (general purpose power splitters, power combiners, phase measurement circuits, phase / frequency discriminators). The MHTXE Magic Tee Hybrid Couplers are available in waveguide bands between 33 and 170 GHz. These couplers are four-port transmission line components with a port configuration as shown in figure. Operation bandwidth is limited to 20÷90% waveguide operation frequency range depending on performance specifications.
-
Product
Regulators For Bias Supply
-
Renesas' low cost linear regulators generate a low voltage bias supply from intermediate distributed voltages commonly used in telecom and datacom applications. These devices may be used as start-up or as continuous low power regulators.
-
Product
Bias Boards
CUBE
-
The CUBE Bias Boards are a set of off-the-shelf biasing boards developed to speed-up the integration process of the CUBE CMOS preamplifier family of XGLab. These boards allow to bias both the detector (SDD as standard, other detector upon request) and the CUBE preamplifier.
-
Product
DC Current Bias Supply
DC1000A
-
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
Product
External DC Bias Adapter
16200B
-
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5 Adc through a 7 mm port by using an external DC current source.
-
Product
DC Bias Current Source
FD1772B
-
• Constant DC output 0-6A• Auto or manual current sweep output• 5 current range output• Output voltage range: 0-11.5V• Current accuracy ± (1%reading + 2digit)
-
Product
Zero Bias Schottky Detectors
-
KRYTAR Zero Bias Schottky Detectors are specifically designed for use in today's high-performance microwave instrumentation and systems. KRYTAR detectors are designed for such applications as power measurements, analyzing radar performance, leveling pulsed signal sources, AM noise measurements, system monitoring and pulsed RF measurements in ultra-broadband and mm-Wave applications.
-
Product
Bias Tee's
-
A bias "T" consists of a feed inductor to deliver DC to a connector on the device side and a blocking capacitor to keep DC from passing through to the receiver.
-
Product
DC BIAS CURRENT UNIT
3265B SERIES
-
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
Product
Low Input Bias Current Amplifiers (<100 pA)
-
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
Product
DC Bias Current Power Supply
TH1775
-
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX02
Frequency Extender
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
110 GHz Frequency Extender, Pulsed DC Bias
N5293AX02
Frequency Extender
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Automatic Bias Controller
MATRIQ-IQABC
Controller
Optimizing DC bias points of an IQ modulator is no trivial task. There are six different Mach-Zehnder structures inside one dual polarization IQ modulator, all simultaneously influencing the properties of a single optical signal. Trying to optimize bias points using just the intensity measurement of the optical signal is time consuming, inaccurate and it requires a lot of knowledge and experience.





























