Transfer Standards
-
product
Standard Voltage 50 Pin D-Type Cables - Connector to Connector for Pickering
The connector to connector cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52B
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Standard Airspeeds
These airspeed indicators have unrestrained movements.These instruments are actuated by ram air and ambient atmospheric pressure obtained from the aircraft pitot and static pressure systems. A moveable pointer and a fixed dial indicate airspeed with the zero index at the 12 o??lock position. Temperature compensation is internal and there is no external zero adjustment. Pointer damping is internally adjustable.
-
product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
4210A Rubidium Frequency Standard
Precise Time and Frequency, Inc.
The ptf 4210A Rubidium Frequency Standard is a unique solution for providing a highly stable, low phase noise, frequency reference for applications requiring atomic reference stability performance.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
product
VXI Rubidium/GPS Frequency Standard
3352A Series
The Racal Instruments™ 3352A Rubidium frequency standard module and the 3352A-GPS, its GPS-disciplined companion, set a new standard for high density functionality in a single width VXI module. Using ANSI Standard M-Module building blocks, the 3352A series integrates the functions of a Rubidium oscillator and clock distribution together with an optional trigger distribution module and an optional digital I/O (DIO) module.
-
product
Standards and Regulations
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard Capacitor
1409 Series
The elements used in 1409 Standard Capacitors are selected for low dissipation factor and are stabilized by heat cycling. They are housed in cast aluminum cases, along with silica gel which provides continuous desiccation. These cases are sealed with high-temperature wax. A well is provided in the wall of the case for insertion of a dial-type thermometer. Three jack-top binding posts are provided on the top of the case, and removable banana plugs on the bottom, for convenient parallel connection without error
-
product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 5.95 (169.00) - 7.55 (212.00) Switch Probe
MSP-25C
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 125Full Travel (mm): 3.18Recommended Travel (mil): 85Recommended Travel (mm): 2.16Mechanical Life (no of cyles): 100,000Overall Length (mil): 1,690Overall Length (mm): 42.93Switch Point (mil): 30Switch Point (mm): 0.76
-
product
Automatic Battery with Filters with Standard Contactors
BATLVF400
Lifasa - International Capacitors, SA
LIFASA automatic capacitor banks are used for centralized compensation of powerfactor in low voltage instalations
-
product
Incremental > Standard Encoders - Hollow Shaft
Incremental > Standard Encoders - Hollow Shaft
-
product
Spectral Radiant Flux / Luminous Flux Calibration Standards
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
product
Nanoscale Microscopy Standards
The nanoscale AFM-CD standard (CD, critical dimension) contains structures to calibrate line widths and periods of AFM (atomic force microscopy) devices.
-
product
Standard Voltage 37 Pin D-Type Cables - Calibration Cables for Pickering
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 37-pin D-type calibration port connector.
-
product
Standards Reference for Test Systems PXI Card
GX1034
The GX1034 offers PXI system designers the capability to develop a system re-certification strategy that employs only internal system resources. By incorporating the GX1034 as part of a system configuration, it is possible to develop a system accuracy verification strategy that can recertify a system's source and measure baseband instrumentation resulting in simplified support / maintenance logistics and improved system availability.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1F-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Resistance Standards
Ohm-Labs manufactures reference grade resistance standards from 10 micro-ohms to 10 teraohms. Each range of standards utilizes the latest advances in materials and processing for high stability and immunity from changes in ambient environment. All products are supplied with ISO17025 accredited calibration.
-
product
Commercial and Open Source Implementation of the Object Management Group Data Distribution Standard
Vortex OpenSplice
Vortex OpenSplice enables data to be shared and integrated across a wide spectrum of operating systems and platforms. It provides a full implementation of both the OMG DDS latest rev1.4 (DCPS profiles) and the OMG-DDSI / RTPS v2.3 interoperable wire-protocol standards. It is targeted for use with server-class (desktops, racks etc.) platforms as well as more specialized real-time embedded environments and operating systems (e.g. single board computer running VxWorks). Vortex Opensplice is fully interoperable with Cyclone DDS, Vortex Link and and Vortex Insight .
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1I8-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1W1S
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
product
Standard Light Source
SLS-50W
OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.
-
product
Ultra Low Noise Disciplined Frequency 4220a Standard with Rubidium and OCXO Clean-Up Oscillator
Precise Time and Frequency, Inc.
The ptf 4220A is an Ultra Low Noise Disciplined Frequency Standard with rubidium and OCXO clean-up oscillator.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) Bead Probe
BTP-1C-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
product
Standard Clamp-On Ultrasonic Transmitter
KATflow 100
The KATflow 100 is a compact clamp-on ultrasonic flow transmitter with a robust and practical design for permanent installation and flow measurement on single pipes.





























