Transfer Standards
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1R1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-C100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard Voltage 37 Pin D-Type Connector Blocks
-
The connector blocks and breakouts below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
PXI/PXIe Microwave Transfer Switch, Single, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount
40-782B-551-E
Switch Module
The 40-782B-551-E (PXI) and 42-782B-551-E (PXIe) single failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
-
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
Product
Coaxial Transfer Switch, DC to 26.5 GHz
L7222C
-
These switches are ideal for manufacturing test engineers working on system integration. Use the Keysight L7222C 4-port coaxial transfer switch in a variety of applications such as a drop-out switch, switching two inputs and two outputs, or signal reversal.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3D
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1UN-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1V1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Standard Voltage 37 Pin D-Type Connector Blocks for Pickering
-
The connector blocks below are suitable to use with Pickering cards and modules that utilize a standard voltage 37-pin D-type connector.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1E
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated for Pickering
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25B-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
-
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
Product
Standard High Speed D/A Converters
-
Analog Devices digital-to-analog converter (DAC) portfolio provides solutions for your high speed and precision DAC applications. Thanks to complete data sheets and evaluation boards, as well as broad support among our clock and timing, RF, power management, and op amp portfolios, our DACs can help you reduce time to market and system design costs. A high speed range from 30 MSPS to multi-GSPS, 8- to 16-bit resolution, and a tiny package are just some of the features that make our industry-leading d/a converters stand out.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Radius, Straight Shaft Bullet Nose, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0J
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 40 GHz, 50 Ω, SMA-2.9, Failsafe, Remote Mount
42-782B-542-E
Switch Module
The 40-782B-542-E (PXI) and 42-782B-542-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 40 GHz. Connections are made via front panel mounted high quality SMA-2.9 coaxial connectors.
-
Product
Standard Voltage 9 Pin D-Type Cables - Connector to Unterminated for Pickering Products
-
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 9-pin D-type connector.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J30
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Sematech Analysis and SEMI Standards Analysis
-
Rocky Mountain Laboratories, Inc.
Rocky Mountain Laboratories, Inc. provides SEMI Standards analyses that conform to the following SEMATECH and SEMI Standards for testing of passivated 316L stainless steel components being considered for installation into a high-purity gas distribution system:SEMASPEC #90120401B-STD (SEM Analysis)SEMASPEC #90120402B-STD (EDS Analysis)SEMASPEC #90120403B-STD (XPS Analysis)SEMASPEC #91060573B-STD (Auger (AES) Analysis)SEMI F60-0306 (based on F60-0301) (XPS Analysis)SEMI F72-1102 (Auger (AES) Analysis)
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25F-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe
42-782B-552
Switch Module
The 40-782B-552 (PXI) and 42-782B-552 (PXIe) dual failsafe transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53