Resistivity
the amount which keeps current from flowing freely.
See Also: Resistance, Resistance Standards, Resistance Meters, Resistance Test, Resistivity Meters, Current, Polarization
-
product
Circuit Breaker Analyzer
CBA 1000
CBA 1000 circuit breaker timing test equipment is a reliable and very accurate operating device for the maintenance and commissioning of circuit breakers in medium and high voltage substation. It can perform static and dynamic contact resistance measurement and it’s an accurate timing speed and motion analyzer.
-
product
Clamp Meters
Omega Clamp Meters provide True RMS Current and Voltage measurements and also include additional measurements typically found in Multimeters such as AC/DC voltage, current, resistance and others.
-
product
Mini Coax, Contact, ITA, RG316
610103115
Primary mating contact 610104114. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
6 Contacts- Circuit Breaker Analyzer
CB14
The CB14 is a 6 contacts circuit breaker analyzer designed to perform Timing, Motion as well as Static & Dynamic Resistance Measurement (DRM) in a single test. It also includes 3 multifunction analog inputs.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25A-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Wallmount Industrial Chassis Supports 10-Slot Backplane
RK-609B
- Supports 10 slot PICMG backplane- Two 5.25" and two 3.5" external drive bays, one internal 3.5" drive bay- Upper cover with captive screw- Drive bay with shock and vibration resistant design- Replaceable and easy-to-clean air filter- 12cm cooling fan (85CFM)- Two USB and one PS/2 keyboard connectors on front panel
-
product
Cryogenic Current Comparator (CCC)
6200A
Measurements International Ltd.
Introducing the Model 6200A Cryogenic Current Comparator Bridge (CCC) from Measurements International (MI) – the ultimate solution for achieving the highest level of resistance calibration accuracy. With an uncertainty of less than 3 parts in 10-9, our CCC surpasses all other technology on the market.
-
product
Alternate 2.39 (68.00) - 6.00 (170.00) Bead Probe
BTP-1HL-6
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2A
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Digital Earth Resistance Tester
8020 ER
Standard Electric Works Co., Ltd
● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Frequency : 820Hz.● 0Ω adjustment.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.● Simplified measurement probe is also provided for two-wire measuring method.
-
product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25H-16
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Salt Spray Chambers
Weice Testing Instrument Co.,Ltd.
The WTS series of salt spray chambers are manufactured and designed to meet the high quality requirements and standards, such as ISO, JIS, DIN, ASTM, IEC, GB and SAE. They are used to test the resistance capabilities of materials eroded by brine, these materials may be used in Electrical Appliances, Electrical Wire, Accessories, Luminaires etc.
-
product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, 22-28 AWG, Crimp, 30µ" Au
610138216
*Please note: The difference between this p/n and 610138116 is the amount of gold plating. See below.P/n 610138116- 50µ" AuP/n 610138216- 30µ" AuPrimary mating contact 610138109. (May mate with other ITA contacts, as well.)Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BeCuContact Plating 30µ" Au over 100µ" NiContact Termination CrimpCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force(lbs) 0.24
-
product
the Impact Shattering
For determining the resistance of aggregates against fragmentation in the impact test. The device consists of the safety housing with doors.
-
product
Direct Reading Attenuator with Remote Control
DA2XE
DA2XE Millimeter-Wave Direct Reading Attenuator is a measurement instrument for signal level setting or loss measurements in waveguide networks. It also can be used for calibration of other attenuation measurement instruments. Direct Reading Attenuators have rotary-vane design. The value of attenuation is determined by rotation angle of resistive film with respect to the waveguide channel. Attenuation value does not depend on frequency. The attenuator has electronic control. The attenuator can be used in local or remote (via USB 1.1 or higher) operation modes.The Attenuators are provided in waveguide bands between 18 GHz and 225 GHz.
-
product
Moisture Meters
Moisture Meters fall into two categories, pin-type and pinless. Pin-type Moisture Meters measure the resistance between test pins inserted into a piece of wood or a building material and use that reading as a proxy for the object''s absolute moisture level. The wetter the material, the less ready it is to be sanded, painted, finished or covered. A best seller is the MMD4E Pin-Type Moisture Meter. Pinless Moisture Meters rely on the ability of moisture to inductively distort an electric field created by turning on the meter. Although Pinless Moisture Meters can only make relative readings, they are nonetheless useful for pinpointing the source of a leak above a ceiling, and for leaving no unsightly pinholes on a finished surface. The MMD7NP is a best selling pinless moisture meter.
-
product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1R2S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
product
Safety Analyzer
SA-2000-INTL
The BC Biomedical SA-2000-INTL Base International Unit Model Features: Same as US BC Biomedical SA-2000 Model, but for users who need a power cord to meet their International Power Needs AAMI Load Earth/Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T80
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Insulation Meter
HT7051
HT7051 has been developed to measure insulation resistance with test voltage programmable up to 5kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, electric cables, electric boards, generic devices, etc.) within BT.
-
product
Multi-channel Resistance Meter
Changzhou Applent Instruments Inc.
Can scan and test 10 channels of resistance and can set a comparator for each channel. Its temperature compensation function can adapt different testing requirements. It can be applied to automation equipment.
-
product
PXI/PXIe High Density Precision Resistor Module
42-297A-114
The 40-297A-114 (PXI) and the 42-297A-114 (PXIe) are 9-channel programmable resistors with a range of 1 Ω to 470 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
Stress Analysis Strain Gages
Bondable foil strain gages (strain gauges) available in thousands of possible pattern designs and combinations of grid alloys, backing materials, resistances, and options.
-
product
EBIRST 50-pin D-type To 9-pin D-type Adapter
93-005-238
eBIRST is a range of USB controlled test tools capable of performing automated path resistance tests on Pickering Interfaces PXI, LXI or PCI controlled switching solutions. Each tool simply interfaces with the switching system's connector so a test can be run using the supplied Windows-based software.
-
product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25I40-2
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
PXI High Density Precision Resistor Module, 9-Channel, 2.5Ω to 3.55kΩ
40-298-023
The 40-298-023 is a high density programmable resistor module with 9 channels which can be set between 2.5Ω and 3.55kΩ with 1Ω resolution The 40-298 range provides a simple solution for applications requiring accurate simulation of resistive sensors. The 40-298 is available in a variety of resistance ranges and resolution capabilities that meet the needs of most functional test systems.
-
product
Micro Power, Contact, Receiver, 21 Amp, PCB Mount
610142102
Primary mating contact 610143101. (May mate with other ITA contacts, as well.)Specifications Operating Current 21 amps continuousContact Resistance 1.5 mOhms max.Dielectric Withstanding Voltage (DWV) 1500 VDC min.Contact Body BrassContact Plating 30µ" Au over 100µ" NiCycle Life 10,000 cyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.23
-
product
ThermalBlade
This ATCA compatible design offers the flexibility to verify the power and thermal characteristics of your Advanced TCA chassis, logic cards and backplane designs. Emulating typical application component heights and features, airflow resistance and enclosure power dissipation can be evaluated and analyzed. A variety of power conditions can be selected and controlled independently to meet your design needs. Maximum sustainable watts are 450 with three switches turned on. Watts are dissipated throughout the entire ThermalBlade equally.





























