CAT
Computer Aided Test
-
product
Differential Probe
DP-16V
*MAX. Input Voltage: ±8KV DC or 16KV p-p or AC 5.6KV rms*Bandwidth: DC-50MHz*Input Impedance 30MΩ// 1.5PF*x20, x200, x2000 Attenuator*To Ground MAX. Voltage: 8KV CAT III*Output Impedance 50Ω
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
12-300V AC Screwdriver Voltage Tester
5130
Peaceful Thriving Enterprise Co Ltd
*Category: CAT II.*With CE and cETL Approval.*Check voltage on 12-300V AC.*Test for voltage and continuity.*Power by two LR44/L1154, 1.5V batteries.*Pollution degree: 2 (accordance with IEC 60664-1)
-
product
FieldFox Handheld RF Analyzer, Up To 10 GHz
N9912C
Select from cable and antenna analyzer (CAT), Vector Network Analyzer (VNA), and/or Spectrum Analyzer with desired maximum frequency. Capture elusive signals with up to 40 MHz gap-free, real-time bandwidth. Measure all four S-parameters simultaneously with 115 dB dynamic range. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
product
Remote Switch Probe
U5404A
This 18 mm test probe is highly recommended for CAT IV environment and is compatible with the U1281A/82A handheld DMMs
-
product
Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.
72-2985
The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.
-
product
Test Lead Set
131139
IEC 1010 Rating: 1000 Volts Cat III Double/Reinforced Insulation 20Amps. Kit Comprises:- 1 Pair 123856/OF-OR/1.2 Double Insulated Silicone Lead Assemblies. 1 Pair 121017 Test Prods. 1 Pair 121026 Sprung Hooks. 1 Pair 126024 Fully Insulated Crocodile Clips. Packed In Silver Wallet.
-
product
AC Sensor
This sensor started it all! Our original handheld sensor detects 50-1000 volts AC and is designed for a CAT IV environment. Always ready for use, this sensor can prevent electrical shock and is non-reactive to static electricity.
-
product
Analyzers and Timers
CAT Advanced Series
Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:
-
product
Voltage/Continuity Testers
VOT-53
Standard Electric Works Co., Ltd
● 2000-count digital display (LCD type). ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function: ACV/DCV: 1000V Resistance: 2000Ω Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard : EN 61010-1 CAT III 1000V EN 61010-1 CAT IV 600V EN 61243-3 EN 61326-1
-
product
Network Toner & Probe Kit
MT-7028
The MT-7028 lets you easily locate and verify the cable status and troubleshoot wiring for continuity, shorts, opens and crossover on RJ45 Lan cable Cat 55e67 (UTP/STP)RJ11/12 Telephone cable Cat. 3 (2/4/6 pin) & normal solid/Stranded wire by alligator clips patch cord. Ideal for all installation and maintenance fields of telecommunication, networking, datacom, Audio/Video, cable TV, and all weather cabling, etc.
-
product
CAT IV 600 A TRMS Navigator Clamp Meter
ACD-50NAV
ACD-50NAV clamp-on power meter offers AC current measurements to 600 A, AC/DC voltage to 1000 V, and wide jaws to accommodate large conductors. This clamp-on multimeter is ideal for industrial power monitoring and verifying system conditions.
-
product
Clamp Meters
Amprobe invented the first clamp meter in 1948 and has continued to innovate and evolve. Today Amprobe offers several categories of clamp meters – from the rugged CAT IV rated Navigator Series, to the versatile Swivel clamp meters, to the compact mini-clamps. Whether you work on residential, commercial, or industrial applications you’ll find an Amprobe tool that fits your needs.
-
product
Bench Type Panel Meter
ED-305
Standard Electric Works Co., Ltd
● Precision meters for plant maintenance, field servicing and educational purposes.● Taut Band movement with rectifier type.● Multi terminals (4mm socket) for range selection.● Carbon pointer, mirror scale to eliminate parallax error.● High resistance to shock and vibration.● Accuracy:±1.5% F.S.● Scale length:80mm.● Dimension:107(L) × 117(W) × 53(D)mm.● Weight:Approx. 300g.● Meets CE EN 61010-1 CAT Ⅱ 600V EN 61326-1 (for 0~600V)
-
product
Analog Insulation Tester
SAIT200
Over voltage CAT. 600V. Battery operated. Solid state circuitry. Automatic circuit discharge. Color coded scale. Fuse protected : Fast blow 0.5A 250V
-
product
AC Clamp Meters
Power measure of Active power (KW), Reactive power (KVAR),Apparent power (KVA), Power Factor (PF)PF (cosØ), for 3Ø4W, 3Ø3W, 1Ø2W, 1Ø3W.Triple display: KW+V+A easy to read.Recorded each wire parameters of V, A, KW, KVA, KVAR, PF, Hz,total 25 parameters.AC current up to 1000A, AC voltage up to 600V.INRUSH (100mS), HOLD and PEAK functions.MAX and MIN recorded functions.MAX. Cable size: Ø34mm.Auto power off (10 mins), Black-light.EN61010-1, 600V CAT IV, 1000V CAT III.Dimensions: 246mm (H) x 80mm (W) x 43mm(D).
-
product
Optical Pickup for Itron Gen™5 Riva™ Meter
1037-RIV
Tesco’s Cat. 1037-RIV is designed to hold the pickup sensor directly above the output location on these new meters. It conforms to the shape of the new meter and secures easily to provide hands free operation.
-
product
CAT-5E Ethernet, Thin Profile, 1M
151733-01
8-Pin Male Ethernet to 8-Pin Male Ethernet, CAT-5E Ethernet Cable - The 8M-8M Ethernet Cable connects devices to network hubs or switches. The cable has straight-through wiring and is available in different lengths and thin profile options.
-
product
Analog Earth Tester
FT3151
Earthing or grounding of electrical equipment is essential to maintain safety, protecting lives, as well as prevent damage to equipment. • Three-electrode method, Two-electrode method (Simple Measurement) • Wide measurement range for 0 to 1150 Ω, based on EN standard •Switchable measurement frequency to reduce the effects of power supply harmonics • Dramatically faster setup: Comes with improved grounding rods and cord winders. CAT II 300 V
-
product
LTE US Version - 4G, Cat.1, GNSS Tracker
Wio LTE
Wio Tracker (Wireless Input Output) is an open source gateway which enable faster IoT GPS solutions. It is Arduino and Grove compatible development boards that helps you track nearly any moving thing on the planet and then upload that data wirelessly. The Wio LTE is the LTE version of Wio Tracker, so now we’ve got 2 versions of Wio Tracker and the LTE (4G) version will make some differences.
-
product
OverHead Lines Contact Voltage & Low Voltage Indicator
LVD-415
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
Battery Tester
CS-3001
The CS-3001 test system records all block voltages, total voltage and current during a discharge test. The modular design makes it easy to connect most of all battery installations, starting from a single block and ending up with 960 block voltages. Up to four parallel strings can be tested. All measuring modules are electrically isolated (600VDC CAT III, 5000VAC test voltage).
-
product
Digital Insulation Mult-Meter
8005 IN
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 50V, 100V, 250V, 500V● The maximum insulation measurement range is 200G ohm @500V.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III
-
product
Double Display TRMS Multimeter with USB Interface
VA42 VA42R VA42RP
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
This instrument complies with IEC 61010-1:2001, CAT II 1000V and CAT III 600V overvoltage standards. See Specifications.
-
product
KYZ Indicator and Tester
1031-C3, 1031-C6
More than just an indicator, TESCO’s KYZ Indicator and Tester Cat. 1031-C3 (3-wire) and 1031-C6 (6-wire) can also be used to perform accuracy testing of KYZ pulses on all TESCO Next Generation Test Equipment. TESCO’s KYZ Indicator and Testers can be used as a pulse input using the same pickup connection on the front panel of all TESCO Next Generation Test Equipment.
-
product
Phase Indicators
Kyoritsu Electrical Instruments Works, Ltd.
New technology permits safe testing, without the need of direct contact between probes and live wires. The insulated crocodile clips can clip insulated cables from 2.4 to 30mm. Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. The instrument can be fixed to a metal panel via the magnet on the back side. Wide measuring range for 3 phase installations from 70V to 1000V AC. Super brightness function permits clear LED''''s indication also in sunshine. Complies with IEC 61010-1 CAT IV 600V and CAT III 1000V.
-
product
Bench Type Panel Meter
ED-205
Standard Electric Works Co., Ltd
● Dimension:91(L) × 103(W) × 100(D)mm● Deflection Angle : 90°● Scale Length:Approx. 65mm ● Terminal: 4mm socket captive head, suitable for wire or pin-type test lead.● Material And Color: Acrylic resin meter cover, white scale plate, plastic stand in black.● Safety Standard: IEC/EN 61010-1 CAT Ⅱ 300V EN 61326-1 EN 61000-4-2 EN 61000-4-3
-
product
Digital Tank Test Kit
4109
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
product
Time Domain Reflectometer
TDR 500
BAUR Prüf- und Messtechnik GmbH
Handheld Time Domain Reflectometer. The handheld time domain reflectometer TDR 500 and TDR 510 are used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on life cables through the measurement category CAT IV / 600 V (with separation filter)* Ideal for fault location in the area of telecommunication, video technology, data and security technology





























