Clamp Earth Resistance Testers
Is used for earth resistance test. This meter uses an EBTN screen with a dual display function (the resistance & current displayed). It also has functions such as a real-time clock, data storage, data review, alarm, and automatic shutdown.
-
product
Transformer DC Winding Resistance Tester
HTZZ-5A / 230
Wuhan Huatian Electric Power Automation Co., Ltd.
Applicable for transformer to submit the dc resistance testproject around group in pick up and overhaul project.
-
product
Standards Tumble Dryer
TESTEX Testing Equipment Systems Ltd.
Standard Tumble Dryer, used for the test of drying process and of the drying procedures needed by other textiles, which are prescribed in the standard textiles test purposed household cleaning and drying procedures.
-
product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
product
Resistance Measurement
Precision resistance measurement equipment for a range of applications. Specialist units measure down to fractions of a micro-ohm with high accuracy.
-
product
Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated for Pickering
The connector to unterminated cable assemblies below are suitable to use with Pickering cards and modules that utilize a standard voltage 50-pin D-type connector.
-
product
Crown, Four Point, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0-Standard
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
product
Insulation Resistance Tester 600V AC/DC
IRT803
UEi Test & Measurement Instruments
The IRT803 Digital Insulation Resistance Tester has a 600V AC/DC measurement capability and auto ranging. It features a backlit display that shows test function and measured value. And is backed by a 1-Year limited warranty.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
AC Measurement Standard
5790B
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
product
Multiparameter CTD with a Wide Choice of Standard Sensors.
MIDAS CTD+
Featuring Valeport’s latest 400 Series electronics, the CTD+ will sample all fitted sensors at exactly the same instant, at up to 8Hz. Advanced setup software allows a variety of sampling regimes including burst modes, delay starts and conditional sampling. Available with up to 64Mbyte memory and internal battery pack, as well as a selection of real-time output formats, the CTD+ may be used with Valeport’s own water bottle carousel.
-
product
Standard 0.30 (8.50) - 1.06 (30.00) Battery Probe
BIP-3
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 60Recommended Travel (mm): 1.52Mechanical Life (no of cyles): 250,000Overall Length (mil): 511Overall Length (mm): 12.98
-
product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-2
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
product
PE/ Ground, Insulation Resistance Tester
Handheld
The safety testers of the Handheld class are used to measure PE/ Ground resistances, insulation resistances and to perform a simple functional test. The small and sturdy universal testers are intended for standard-compliant safety tests in workshops and production as well as for mobile operation during repair, installation, service and more.
-
product
Standard Resistor Oil Bath
9400
Measurements International Ltd.
Measurements International’s series of fluid baths are used for the maintenance of standard resistors and shunts. The 9400 has been designed after compiling years of customer feedback on existing resistor oil baths.
-
product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72F-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard Normally Open
Is an optically coupled element that combines a GaAs infrared LED on the input side with anormally-open MOS FET on the output side to realize an excellent cost performance.The small, thin package and high sensitivity of this element makes it ideal for battery-driven mobile devices, and its small offset voltage at power-on and good linearity are also make it suitable for controlling micro analog signals.
-
product
Handheld Digital Multimeter, 4 digit, Water and Dust Resistant
U1271A
Feature sets that meet traditional industrial requirements and improve productivity and safety Improved accuracy and resolution to meet traditional industrial requirements (30,000 counts resolution with 0.7% for ACV accuracy)Intelligent features to improve productivity and safety (selectable Low Pass Filter LPF and quick signal type identification Qik-V)Better grip Both visual and audible continuity indication in noisy environments Easy access to fuse for simplified maintenance Easy connectivity to PC and internal memory (up to 200) for data logging Large rotary switch and buttons that are easy to operate Dust and water resistant casing (IP 54 compliant)Compatible with U1177A/U1117A IR-Bluetooth adapter for remote monitoring & datalogging Altitude: 3000 meters
-
product
NanoCD Standards (NCD)
The NanoCD™ (NCD) is the first commercially available standard to provide line width accuracy calibration at the 45 nm, 65 nm, 90 nm and 130 nm nodes. Use these standards for tool matching, calibrating the width of a CD-AFM tip, or CD-SEM diagnostics.
-
product
Surface Resistivity Meter
395
The ACL 395 handheld meter features sophisticated circuitry that allows for the same advantages as megohmmeters, but at an economical price. Utilizing color-coded zones, the LED scale is easy to read and evaluate. Half decades indicate where the measurement value falls within the decade giving a closer indication to actual value. Unlike other pocket-sized meters, the ACL 395 features rubber rails which provide the best possible contact.
-
product
NanoLattice Pitch Standard (NLSM)
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard In-door Forward Optical Receiver
HR8636
Hangzhou Huatai Optic Tech. Co., Ltd.
HR8636 with standard configuration is a type of high index and universal in-door forward optical receiver. It adopts Philip optical receiving module. End-grade adopts power-doubling module. Optical connectors and RF connector can be installed at the front panel or back panel.
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-1C1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Uniform Light Sources, Luminance Standards
Uniform light sources for the adjustment of pixels and intensity of image sensors and cameras as well as for the calibration of luminance and spectral radiance or in other words: Solutions for Imaging, Sensing & Remote Sensor Calibration.
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2H
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
AC Resistance Bridge
SIM921
Stanford Research Systems, Inc.
The SIM921 AC Resistance Bridge is a precision, low-noise instrument designed for cryogenic thermometry applications. With excitation power below 100 aW, thermistors and other resistive samples can be measured at temperatures below 50 mK with negligible self-heating errors