Filter Results By:
Products
Applications
Manufacturers
Impedance
-
product
Impedance Analysis For E5061B-3L5 LF-RF Network Analyzer
E5007A
The E5007A provides the impedance analysis (ZA) firmware for the E5061B LF-RF network analyzer. This option enables the analyzer to measure impedance parameters of electronic components such as capacitors, inductors, and resonators. The combination of NA and ZA capabilities further enhances the analyzer’s versatility as a general R&D tool. Basic ZA functionalities including fixture compensation and equivalent circuit analysis are supported by the firmware. The DC biased impedance measurement is possible with the built-in DC bias source provided by the E5061B-3L3/3L4/3L51.
-
product
Automatic Tuners10MHz – 140GHz
Load Pull
An impedance tuner is an apparatus, which generates controllable reflection factor (Impedance) over a certain frequency range.
-
product
Potentiostat/Galvinostat Electrochemical Instuments
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
Transducer Simulator
Model 7
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
product
Digital Multimeter
DM500MAX
The DM500MAX is designed for harsh environments with a watertight gasket as the seams rotary switch, an input terminal, and battery cover to keep out dust, dirt, and splashing. They can also take shocks and drops, work anywhere from indoor to outdoor, and special designed LoZ(Low Impedance) feature to prevent false reading caused by ghost voltages.
-
product
Impedance Analyzer
MFIA
The Zurich Instruments MFIA is a digital impedance analyzer and precision LCR meter that sets the new standard for impedance measurements in the frequency range from DC to 5 MHz. The MFIA provides 0.05% basic accuracy and a measurement range spanning from 1 m to 10 G. The instrument has a high measurement repeatability and a small temperature drift. With the LabOne user interface the MFIA offers a number of long-awaited innovations for the impedance and LCR measurement available without the need of any software installation.
-
product
Audio Impedance Testers
1107 IM
Standard Electric Works Co., Ltd
● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.
-
product
High Voltage Meter
STME-VM
Statclean Technology (S) Pte Ltd
This is a High Input Impedance Voltmeter with 70 Gigohm input impedance. Capable of measuring up to DC voltage up to +/-5.5kV with 1.0V resolution over a range of himidity and temperature, the meter measures with better than 1% accuracy without loading the power source. Its compact size and light weight body allows applications in laboratory and field work when powered by battery.
-
product
Differential Probe
DP-35
*High Sensitivity, High Voltage Model .*35MHz/1600 Vp-p Max.*Input Impedance 8MΩ//2.5PF*x10, x100 Attenuator, Easy to Convert.*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Differential Probe
DP-25
*Econmical High Voltage Model*25MHz/1400Vp-p Max.*3 Range: x20/ x50/ x200*Input Impedance 4MΩ//1.2PF*Separating Design(Standard No.114205) Convenient & Durable.
-
product
Battery Impedance Tester
TES Electrical Electronic Corp.
Test conditions without shutting down battery.Simultaneously measures battery resistance, Voltage, current, and temperature.Auto-hold and auto-data storage. Comparator Function.Rates conditions as pass, warning, or fail.
-
product
High Impedance Busbar Differential Relay
MIB
The MIB, a member of the M II family of economical and highly functional digital protection relays, is a microprocessor based relay that provides three phase high impedance differential protection for Substation Bus-bars of any voltage level. Use the MIB also to protect electrical machines like transformers, generators or motors against restricted earth faults.
-
product
Broadband Dielectric Spectroscopy
Material Sensing & Instrumentation
Broadband Dielectric Spectroscopy is a powerful tool for investigating a variety of dielectric processes for both electrical and non-electrical applications. Also called Impedance Spectroscopy, the measurement separates molecular process on the basis of response time, providing a unique relaxation frequency along with a signature variation with frequency.
-
product
Calibration Kit
N1802
N1802 Calibration Kit, Frequency Range: up to 18 GHz, Impedance: 50 Ohm, Connector Type: N-type Male
-
product
Differential Probe
DP-02VF
*150MHz High Frequency*MAX. Input Voltage:*±40V DC or 80V p-p or AC 28V rms*Bandwidth: DC-150MHz*Input Impedance 1MΩ // 7.5PF*X2, X20 Attenuator*To Ground MAX. Voltage: 40V*Output Impedance 50Ω
-
product
High Impedance Differential Relay
High impedance protection schemes are widely used for the protection of BUS bars, generators, motors & power transformers. BUS bar protection schemes utilizing electromechanical high impedance differential relays are often used due to their simplicity, reliability & comparatively low cost.
-
product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
product
Controlled impedance test system
CITS900s4
CITS900s4 is the seventh generation of Impedance test system from polar, and typically the most popular model for customers who are new to impedance control. CITS900s4 provides both differential and single ended measurement capability along with 4 channels to provide flexible probe connection.
-
product
Impedance Analyser Frequency Response Analyser
C60
The C60 investigates the opaque world of analog networks. The unit operates in two test modes. It can measure the frequency response of a two port system producing a gain/loss and phase graph. It can also measure the reactive response of a two terminal network producing an impedance/admittance and phase graph. Electronic, electrical, electro-acoustic and other networks can be tested with sine wave excitation and the results displayed on a PC.
-
product
Differential Probe
DP-08VF
*MAX. Input Voltage: ±400V DC or 800V p-p or AC 280V rms*Bandwidth: DC-150MHz*Input Impedance 20MΩ // 5PF*X20, X200 Attenuator*To Ground MAX. Voltage: 400V*Output Impedance 50Ω
-
product
Transducer Simulator
Model 0V
SPECIFICATIONS: Impedance: 700 ohms nominal. Output Ranges: 10 turn vernier 0 - 3mV/V. Excitation: 20v ac/dc max,
-
product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L
Current Rating (Amps): 5Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 1.90Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
product
NM-SF 50 N-Male to SMA-Female Adapter
NM-SF 50 Adapter, N-Male to SMA-Female, Frequency Range: DC to 18 GHz, Impedance: 50 Ohm
-
product
The Leading Measurement System for the Analysis of Porous Materials
ELWIS
ELWIS (Evaluation of Light Weight Impedance System) offers a full and rapid characterization of porous materials based on the analysis of a single sample. The ELWIS system consists of the ELWIS-A and ELWIS-S components which can be used independently from each other although both applications are needed for a complete material simulation.ELWIS-A measures acoustic parameters that are needed to evaluate the acoustic performance of sound insulation and sound-absorbing multi-layer materials. An additional impedance tube for absorption measurements at higher frequencies is available for ELWIS-A.ELWIS-S measures structural parameters that are needed to simulate the dynamic and acoustic behavior of sound packages in the medium to low frequency range (including the "Poisson Ratio" for foam materials).ELWIS is very easy to operate: Thanks to its user-friendly software, the system can also be used to obtain reliable results by users with only limited experience in the characterization of porous materials.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
Calibration Kit
N912
*N912 Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Line Impedance
KIT
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53