Filter Results By:
Products
Applications
Manufacturers
-
product
Magnetic Flux Leakage Testing
PRÜFTECHNIK Condition Monitoring GmbH
NOVAFLUX - Flux Leakage Inspection for Black or Bright Steel Bars
-
product
Industrial Gaussmeter
The industrial gaussmeter IGM11 is used to measure magnetic DC and AC fields. The measurands are flux density in Tesla or Gauss and the field strength in Amps per meter.
-
product
Electromagnet
The electromagnet can generate strong magnetic fields for experimental applications. Depending on the required magnetic flux density and Equipment under test volume the air gap can be adjustedcontinuously. The magnet poles come with conical shape close to the test volume to improve accessability and to optimize the achievable magnetic flux density.
-
product
Hall Effect Measurement system
HMS-3300
Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.
-
product
Polarity Tester
PT-1
International Electro-Magnetics, Inc.
The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.
-
product
Continuous Magnetic Measurement Equipment
CWM
The automatic measurement equipment to continuously measure magnetic property in commercial power frequency of magnetic steel sheet sample on line, is used for quality control. Core loss in definite time of magnetic flux density [B] or magnetic flux density [B] in definite time of strength of magnetic field [H] for excited magnetic steel sheet is measured on line.
-
product
Hall probes
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.
-
product
Zero Field Cavity
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
product
AC Magnetostriction Measurement Equipment
TLVM
This equipment measures quantitatively magnetostriction to indicate mechanical striction in magnetizing direction caused when magnetic steel sheet sample was alternately magnetized and is used for research and development of magnetic steel sheet. Magnetostriction is detected as speed signal through the parameters of magnetic flux density and compressive stress with laser doppler vibration meter.
-
product
Fluxmeters
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.
-
product
Wire Rope Detector
It adopts the method of magnetic flux leakage and magnetic flux, and uses the Ethernet high-speed transmission method, which can accurately complete the non-destructive testing of the wire rope in service.
-
product
Search Coils And Field Measuring Coils
Designed to measure the magnetic flux on magnets or in the airgap of magnet systems.
-
product
D.C. Recording Fluxmeter
TRF
This is the equipment being able to measure direct current magnetization property of wide-ranging magnetic materials from soft magnetic materials to high performance permanent magnet with magnetic flux meter based on M integral closed magnetic circuit system.
-
product
Handheld Gaussmeter
HGM09
Data storage on a personal computer via keystroke. The HGM09s is easy to use and has a good price/performance ratio. The handheld gaussmeter HGM09s is used to measure magnetic DC and AC fields. The measurands are flux density in Tesla or Gauss and the field strength in Amps per meter.
-
product
Fluxmeter
480
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
product
Digital Flux Meters
Digital Fluxmeter is instrument made by electronic integration principle and displays the magnetic flux digitally. It can test magnetic materials. It not only measures flux but also directly tests magnetic performance for the purpose of quality control. With the features of legible display and convenient operation, it is an ideal device for flux measurement.
-
product
Magnetic Field And Permeability Measurement
MAGNETOMAT 1.790
Foerster Instruments, Incorporated
The MAGNETOMAT 1.790 is a measuring system for the precision detection of magnetic flux density and relative permeability. The MAGNETOMAT software is used for displaying the measured values and saving and exporting data. The wide range of probes facilitates optimal adjustment to the conditions of the application, such as the measurement of relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys. Further applications include the long-term monitoring of the magnetic environment, e.g. prior to installing magnetically sensitive devices, and the localization of ferrite enclosures in stainless steel and NE materials. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.
-
product
Fluxmeter
480
The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.
-
product
Motor/Gasoline Engine RPM Detector
OM-1500/1200
The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).
-
product
Microprocessorized fluxmeter
MSM-101
Mobile meter designed to measuring the quasi-static changes of magnetic flux association with induction sensors. The minimal range of meter is equal 0.001Wb/V and drift under 7x10-6Wb/min.
-
product
Magnastick
MSL
The Magnastick™ MSL™ magnetometers seeks ferromagnetic objects by sensing their magnetic fields. Dual toroidal sensor coils are highly sensitive to the magnetic lines of flux naturally present in ferrous (iron) materials and are not affected by non-ferrous materials such as brass, aluminum, or copper.
-
product
Fluxmeters
Hirst Magnetic Instruments Ltd
Fluxmeters for advanced measurements a Fluxmeter can be used to measure Magnetic Flux Linkage where a surface reading with a Gaussmeter is not sufficient.
-
product
Custom Magnetic Recording Heads
International Electro-Magnetics, Inc.
We have manufactured over 5,000 different head designs. If we don't have one to suit your requirements, we will design and build to your specification. Our toolroom is well equipped to produce precision parts, and our design projects have included flux sensing systems, magnetic disk encoding, and electronic test equipment.
-
product
Reference Magnet
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
product
Probes for Tube Inspection
Probes for tube inspection are lightweight but solidly constructed eddy current, remote field, magnetic flux leakage, and IRIS ultrasound. These probes are used for ferromagnetic or non-ferromagnetic tube inspection applications.
-
product
Magnetic Particle Inspection
Shanghai Xianda Denshijiki Industry Co.,Ltd
Using the "leakage magnetic flux" phenomenon generated from the scratches, the magnetic powder (or fluorescent magnetic powder) of the ferromagnetic material scattered on the surface by magnetizing the specimen is adsorbed to the scratch. Observe this and detect scratches.
-
product
L.V.D.T Products
Columbia Research Laboratories
Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.
-
product
Field Strength Measuring Instruments and Sensors
MAGNET-PHYSIK Dr. Steingroever GmbH
Field strength measuring devices are measuring devices for measuring the magnetic flux density B (formerly also called induction) and the magnetic field strength H of direct and alternating fields. They are also called Gaussmeters or Teslameters.
-
product
Helmholtz Coil
In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.
-
product
Digital Tesla Meter
HT208
Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours