Luminous Flux
-
Product
Total Luminous Flux Measurement System
-
This system enables the total luminous flux measurement of luminous intensity distribution 2 and 4 light sources based on the measurement standards of LED lightings LM-78 and LM-79 approved by IESNA (Illuminating Engineering society of North America) .
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Absolute Luminous Flux Integrators
-
Photometric Solutions International Pty Ltd
The Absolute Luminous Flux Integrator (ALFI) is a special device for absolute measurement of the luminous flux output of lamps. It can also to measure the luminous intensity distribution of small lamps and luminaires.
-
Product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
Product
LED Fast-Scan Micro-Spectrophoto Colori meter
8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.
-
Product
PCE Series Opto-Electric Measurement System
-
Hangzhou Everfine Photo-E-Info Co., LTD
This system delivers various photometric, colorimetric and electrical parameters as required by CIE standards.Measurement parameters are luminous flux (with integrating sphere), relative spectral power distribution, chromaticity coordinate, CCT(correlated colour temperature), CRI (color rendering index), SDCM (standard deviation of color matching), color purity, peak wavelength, dominant wavelength, etc.
-
Product
Integrating Sphere Based Spectroradiometer Systems
-
Spectroradiometer systems with integrating sphere for the measurement of UV-VIS-NIR spectral radiant flux (W/nm) and luminous flux (lm) and chromaticity metrics.
-
Product
Spectroradiometer
-
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
Product
Backlights for Machine Vision
-
Backlighting is one of the most important components of machine vision systems; it must provide the required luminous flux, response speed, area and duration of exposure. Our experience in machine vision systems led us to the need to develop an LED backlight module for flash operation.
-
Product
Light Meters For Photometry
-
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
Product
Spectral Light Meters For Photometric And Colorimetric Measurements
-
Comprehensive range of spectroradiometers for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens), luminous intensity (cd) as well as the colorimetric characteristic values such as chromaticity coordinates (x,y,u',v') or color rendering index (CRI), etc.
-
Product
LED Goniophotometer For Led Tester
CX-880
-
Shenzhen Chuangxin Instruments Co., Ltd.
880 LED Test machine is used to measure: 1.the luminous intensity dirstribution curve, 2.intensity data, 3.spread angle and equivalent luminous flux of small lamps.
-
Product
LED Tester0.3m-2m Integrating Sphere
CX-8000
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
Product
Integrating Sphere
-
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
Product
Goniophotometer
-
A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.
-
Product
GO-NR1000 Near-Field Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
Product
PHOTO-2000Z Multiphotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
PHOTO-2000Z can be used for luminous flux (supporting integrating sphere) and illuminance test, portable design, high test accuracy, not only suitable for laboratory, quality inspection department, R&D department, but also for industrial and commercial field measurement.
-
Product
Integrating Spheres
IP-Series
-
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
Product
Optical Meters
-
The Gamma Scientific range of light meters includes handheld and benchtop models. Configuration options include a wide range of sensors and calibrations in units including: Luminous Flux (lumens) or Radiant Flux (Watts), Illuminance (lux, foot-candle) or Irradiance (W/cm2 ), Luminous Intensity (candela) or Radiant Intensity (W/sr), Luminance (cd/m2 , foot-Lambert) or Radiance (W/m2 sr), or Pulse Energy (Joules). Cooled sensors and reference standard detectors are also available.
-
Product
Integrating Spheres - Luminous Flux Measurement For LEDs And Lamps
-
Konica Minolta Sensing Americas, Inc
One of the most important tests in light measurement is the assessment of the total radiant power or luminous flux of light sources using integrating spheres. An integrating sphere’s inside surface is coated with a diffusely reflecting material which guarantees complete integration and homogenization of the emitted radiation. The integrated light is then measured at the detector port.
-
Product
GO-SPEX100 Goniospectroradiometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
GO-SPEX100 delivers photmetric, colorimetric, electrical comprehensive test function for LEDs, and built-in precision temperature control platform,not only for measuring the specific temperature of the photometric and colorimetric parameters of LED, but also to measure the characteristics curve of its photometric and colorimetric performance with temperature.The test parameters include: spatial luminous intensity distribution curve, luminous flux, spatial spectral distribution, relative spectrum, absolute spectrum, color parameter, forward current and forward voltage, etc.
-
Product
Integrating Spheres
-
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
Product
Instrument Systems LED And Display Measurement
-
Konica Minolta Sensing Americas, Inc
Instrument Systems is a frontrunner in developing state-of-the-art light measurement equipment, software, and accessories, taking great pride in constructing products that provide fast, accurate readings to ensure precise data for laboratory, production and quality assurance testing. All Instrument Systems products have stringent quality and performance requirements to ensure that customers get the highest quality equipment. As a leading supplier world-wide, they provide cost-sensitive support to a diverse clientele to help them measure luminance, flux, intensity, illuminance, and chromaticity of LEDS, lamps and displays throughout all aspects of product development and production.
-
Product
GO-R5000 Full-Field Speed Goniophotometer
-
Hangzhou Everfine Photo-E-Info Co., LTD
The GO-R5000 integrates more powerful functions such as near field, middle field and far field distribution goniophotometer, which can be used for spatial luminous intensity distribution and total luminous flux test of indoor lighting lamps, floodlights, street lamps, etc. Equipped with imaging luminance meter and spectroradiometer, it can measure the spatial luminance distribution and spatial spectral color distribution of the light source.
-
Product
LED Goniophotometer for Lamps
880
-
Shenzhen Chuangxin Instruments Co., Ltd.
Be used to measure the luminous intensity distribution curve intensity data spread angle and equivalent luminous flux of luminaries. Computer controls the whole test process automatically with low cost and simple operations.
-
Product
RGB Laser Illuminance, Luminance & Optical Power Meters
TM6102/TM6103/TM6104
-
Accurately evaluate the white balance of displays that use lasers by measuring centroid wavelength and optical power, which are key characteristics in the evaluation of laser light sources. Designed to adjust and inspect RGB lasers. Meters measure radiant illumination, centroid wavelength, illuminance, luminance, chromaticity, Radiant flux (optical power) and luminous flux.
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
High Power LED Photo-color-semi Automatic Selector
-
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
Product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
-
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.