Furnaces
-
Product
High Temperature Furnace COD Gages (1200 C or 1600 C)
Model 3548COD
-
Jinan Testing Equipment IE Corporation
These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
Product
Non Contact Temperature Sensors
-
Non Contact Type temperature measurement involves determining temperature of object surface without direct contact with the surface. Tempsens offers both single point and area inspection model devices which are infrared thermometers and infrared camera and industrial furnace monitoring camera.
-
Product
Hydrogen Analyzer
H‑500
-
Determination of hydrogen using the heat extraction method is a special requirement for the characterization of steel, steel alloys, copper and other metals. ELTRA’s H-500 is designed for the rapid and accurate determination of hydrogen in these materials. The H-500 analyzer uses the heat extraction technique and is equipped with a resistance furnace with quartz tube. The temperature can be set up to 1000 °C in steps of 1 °C. The usual working range of the H-500 is about 900° to 1000° C.
-
Product
OEM Gas Pressure Switch
1996
-
Reliable and convenient, the 1996-5 and 1996-20 Gas Pressure Switches serve as a compact, low cost switch for gas fired furnaces and equipment. Pressure ranges for both models are ideal for high or low gas pressure interlock. Visible set point and on-off indicators add convenience in servicing
-
Product
Furnace Calibrators
-
Electronic Development Labs, Inc.
High-precision heating instruments designed to calibrate temperature sensors.
-
Product
Carbon / Sulfer Analyzer
ELEMENTRAC CS‑i
-
The elemental analyzer ELEMENTRAC CS-i measures the carbon and sulfur concentration in predominantly inorganic samples through combustion in an induction furnace and the subsequent analysis of the gaseous combustion products carbon dioxide and sulfur dioxide.
-
Product
Spherical Blackbody Source
Cyclops Model 878
-
The Cyclops Model 878 is a spherical blackbody source. It consists of an inner black sphere that sits inside a spherical furnace and is suitable for use as a radiation source for infrared thermometers.
-
Product
Air Core Harmonic Filter Reactors
-
Use of nonlinear loads such as power electronics based equipment and electric furnaces have been on the rise for the last decades. Such loads decrease the power quality of the network that they are connected to. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Thyristor Switches
SC Series
-
SC Series Thyristor Switches are used in systems which contain fastswitching inductive loads. The capacitors, which will be used to provide capacitive power to the system, can be switched on and off with a switching time shorter than 20 ms (1 period) by using SC Series Static Contactors, thereby providing a more effective compensation for fast-switching loads such as tack welding machines, cranes and arc furnaces.
-
Product
Pyroelectric and Thermal Testing
-
The optional Chamber Task measures the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled within a thermal chamber, on a hot chuck or in a furnace. From these measurements the Spontaneous Polarization Pr(q) and the Dielectric Constant er(q) are computed. These are then combined to determine the Electrical Displacement D(q) as a function of the temperature q.
-
Product
Radar solution for level of melting furnaces
-
With OndoSense radar sensors, you can measure the fill level in the melting furnace or crucible contact-free with sub-millimeter accuracy – even at metal temperatures of up to 1600 degrees Celsius. A high-precision, continuous level measurement in the melting furnace is required in particular for the recycling of scrap metal such as aluminum, steel or copper. This way, you can determine exactly when the metal has completely melted.