PXI Generators
-
product
PXI Power Multiplexer, 18-Channel, 1-Pole
40-665A-001
Model 40-665A-001 is a 18-Channel 1-Pole Power Multiplexer, suitable for switching inductive/capacitive loads up to 10A at 250VAC. It is available with a choice of 1-pole (10A) or 2-pole (8A versions).
-
product
Programming File Generation
Corelis will process your design information, create all necessary programming files, and verify the programming works using your actual hardware. This is a complete "turn-key" service resulting in a fully functional flash programming solution. For companies short of resources, those who are under a tight deadline, or for those who are new to boundary-scan and need a programming solution in the shortest time possible, this is an excellent way to minimize your investment and maximize your effectiveness.
-
product
GNSS Signal Generation System
GSS6300
The Spirent GSS6300 has been specifically designed to facilitate high-volume production testing for GNSS-enabled applications. Capable of generating a single channel of multiple GNSS in the L1 band individually or concurrently, the GSS6300 offers the fidelity and reliability needed for final functional testing of high-value critical systems.
-
product
6U I7 PXI Controller
GX7927 Series
The GX7927 is a Single Board Computer (SBC) that features the high performance, highly integrated Core i7 processor platform from Intel. Core i7 offers an integrated graphics and memory controller plus dual core processing, operating at speeds up to 2.53 GHz. Coupled with the Mobile Intel QM57 Express Chipset, the GX7927 provides an unmatched level of I/O bandwidth for both onboard and off-board functions. The module is supplied with 4 GB of DDR3 SDRAM and 16 GB of NAND Flash memory. Both standard and extended temperture operation range versions are available.
-
product
Optical Delay Generator
The FR-203 provides periodic linear optical delay (~200ps) for ultrashort laser pulses. It is useful for applications such as time resolved spectroscopy and time domain terahertz spectroscopy. A well defined optical delay is generated with interferometric precision.
-
product
High-Power PXI Switch Matrix Modules
These high-power PXI switch matrix modules provide higher current and power ratings than the high-density switch versions. These modules are designed for the switching of AC or DC loads or for controlling large relay or solenoid systems. The solid state relay matrices occupy two PXI slots and are suitable for automotive and aerospace test applications.
-
product
Handheld Broadband Noise Generator
NS-1
The Model NS-1 is a handheld broadband white Gaussian noise source. It generates a wide, even, RF noise-signal. The NS-1 is popular for testing network components and aligning a building's coaxial cable network. The NS-1's noise-signal is also used to provide the RF source for measuring insertion loss of cable, splitters, taps and more.
-
product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
product
PXI Power Relay Module, 10xSPST, 16 A
40-161A-003
The 40/42-161A-003 is a PXI/PXIe 10xSPST power relay module and is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock. Electro-mechanical power relays are used wich are suitable for switching loads up to 16 A at 250 VAC.
-
product
PXI Fault Insertion (Fault Injection) Modules
PXI Fault Insertion Units (FIU), also known as Fault Injection switch products, are designed specifically for safety-critical applications where the response of a control system is required to be evaluated when sensor connections behave in unexpected ways. These modules are scalable solutions that can be used to switch signals between simulations and real-life devices in a multitude of hardware-in-the-loop (HIL) simulation and test systems. The fault insertion unit can significantly simplify and accelerate the testing, diagnosis and integration work in HIL applications.
-
product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3D-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
PXI Vector Network Analyzer
PXI Vector Network Analyzers feature two ports, so you can choose between T/R test sets or full S-parameter capabilities. The PXI Vector Network Analyzer supports automatic precision calibration, full vector analysis, and reference plane extensions, so it is an ideal vector network analysis solution for your validation and production operations without the high cost and large footprint associated with a traditional benchtop VNA. These models seamlessly integrate into test systems for highly accurate, fast RF measurements.
-
product
PXI And PXIe Chassis
PXI chassis and PXI Express (PXIe) chassis available in 8 to 19 slots and different performance characteristics. These chassis are fully compliant with PXI standards and can house any vendor’s modules. Our Gen 3 PXIe chassis offers full hybrid capability on all peripheral slots, giving you the flexibility needed to choose whichever PXI or PXIe products best fit your applications.
-
product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2J40-1
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
PXI Integration Platform
ATS-3100
The new ATS-3100 enables you to rise above the module level and shift your focus to the sophisticated test solution you’re actually building. Simply add your instruments, software, and customization to create a complete solution. Or, if you're short on time or resources, ask Astronics Test Systems to do the finishing work for you.
-
product
PXI 2A Multiplexer, 8-Bank, 8-Channel 2-Pole
40-614-004
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PXI Instrumentation
Build high-performance, mixed-measurement systems with NI’s easy-to-scale PXI platform.
-
product
Connect Generators to the Grid
GridCode
DIgSILENT has developed a new verification tool called DIgSILENT GridCode. The software has been designed in response to the need to verify whether a conventional or renewable power plant is compliant with local Grid Code interconnection requirements on basis of generating unit tests. There is a new trend towards verification of requirements at the point of interconnection of a power plant using transient stability simulations with numerical models. An increasing number of Transmission System Operators are including model validation methods to quantify the risk and uncertainty when using these simulation models in stability studies. These new methods have been included in the DIgSILENT GridCode tool.
-
product
Double Voltage Double Frequency Generator Setup
DVDF
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
product
Internal 6 GHz Arbitrary Waveform Generation
S93072B
Enables active device measurements with modulated signals from the internal sources of PNA/PNA-X including the XSB port on 4-port PNA-X
-
product
PXI Voltage Amplifier SMB Type Connector
41-650-002
A 5 channel voltage amplifier ideal for increasing the output voltage from other PXI modules, enabling users to easily generate the signal voltages commonly required in applications such as automotive test.
-
product
Generators
Saw-Tooth Signal Generator
The Software Signal generator allows to produce triangular and saw-tooth (descending, ascending) signals at the DAC output.
-
product
Pulse Generators
Active Technologies Pulse Generators can be used to set up continuous or triggered pulse streams and offers flexibility to address the most challenging applications like big physics, automated testing, microwaves, modulators, wireless communication, medical and chemistry.
-
product
PXI 40Amp 14Volt 2xSPST Automotive Relay
40-180-001
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDCThe 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
product
PXI 2A Multiplexer, 2-Bank, 64-Channel 1-Pole
40-614-010
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
product
PathWave BenchVue Function Generator App
BV0002B
The PathWave BenchVue function generator app helps control function generators intuitively, load/design arbitrary waveforms, and build automated tests quickly.
-
product
General Purpose Probe
HT-2
HT-2 ''Workhorse'' General Purpose Probe - designed for temperature measurement of liquids, gases and semi-solids. Plastic handle with straight 9'' stainless shaft. Not good for surface temperatures. Maximum temperature 400°C, Time constant 0.5 Seconds. 5 foot lead. Not isolated.
-
product
PXI 10A Power MUX 4-Bank 8-Channel
40-661-002
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3G-1
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02




























