Harmonic
Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.
-
product
DR Range Broadband Power Amplifiers 10 KHZ - 400 MHZ
DR Series
Class A solid stateBroadband (instantaneous single band): 10 kHz 400 MHzTypical output power : 60 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB > 40 W and H<-20 dBc up to 250 MHz andP1dB > 25 W and H<-20 dBc from 250 MHz to 400 MHzAir cooling: self contained fansCan operate in full mismatch conditions without damageReliable, efficient and robust19" Rack3 years standard warranty
-
product
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger
SD750100G
Zhejiang Sandi Electric Co., Ltd
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.
-
product
Digital Power Meter, 30A
66205
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
product
Nonlinear Pulse-Envelope Domain
S94518B
The S94518B Nonlinear Pulse-Envelope Domain measures the vector corrected amplitude and phase of the fundamental and harmonic pulse envelopes of your DUT.
-
product
LV Iron Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Portable Test System
MT786
Actual value, vector, curve displayCurrent and voltage generationerror measurementMeasurement of harmonics up to the 40th
-
product
Digital Multitesters
SDM620/622
4000 Counts Display. 41 Segments Analog Bar Graph. True-RMS. Capacitance (Max 4000uF) ? Temperature. Harmonic distortion (SDM622 Only)
-
product
Automotive Radar Echo Generator
AREG800A
The R&S®AREG800A Automotive Radar Echo Generator is an innovative and versatile solution for testing automotive radar sensors. Thanks to the flexible and scalable concept of the R&S®AREG800A and the full harmonization with the R&S®QAT100 Advanced Antenna Array, the solution fulfills the test requirements of the most advanced radar echo generation applications. The R&S®AREG800A
-
product
Power Analyzers & Wattmeters
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
product
Power & Energy Analyzer
PS3550
The PowerSight PS3550 Power Analyzer is a versatile, easy-to-use 3-phase power analyzer that is ideal for energy audits, load studies, harmonic analysis, and more. The PS3550 couples its small size with a wide range of operating modes and measurement accessories to help you get the measurements you need, both now and into the future.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
HVDC Power Filter Characteristic Test Set
FT3000
FT3000 Power Filter Characteristic Testing equipment has the functions of automatic sweep harmonic signal output, A-F and P-F characteristic measurement/display etc. It can perform HVDC Power Filter Testing and is mainly used in AC filter of DC convertor station, DC filter tuning characteristics test and parameter test of R, L and C. It is also used in electrified railway HV filter, passive power filter client and conventional AC substation reactive compensation device.
-
product
Test Compliance
MX CTS Series
AMETEK Programmable Power, Inc.
A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.
-
product
Power Quality Analyzer
PQA820
PQA820 respectively record 383 and 44 quantities which can be recalled and dragged onto the screen to be compared between each other; for example, if you are displaying the trend of voltages and you want to check for the possible presence of harmonic distortion, it will be sufficient to scroll through the list of recorded measures and drag the one relevant to harmonics to the screen. The same can be done for all other quantities: power, cosphi, current, energy, etc.
-
product
Solid State GaN (Gallium Nitride) Amplifiers
Fairview Microwave’s solid state GaN (Gallium Nitride) power amplifiers (also called SSPAs) feature broad frequency bands ranging from 30 MHz to 7.5 GHz and very high gain levels from 43 to 60 dB. These GaN SSPAs also show impressive harmonic response (-15 to -20 dBc) under worst case conditions. Saturated output power levels range from 10W to 100W with 20% to 35% Power Added Efficiency (PAE). All of our high power solid state GaN amplifiers from Fairview have internally regulated single voltage supplies. Our GaN SSPAs are designed to withstand environmental conditions such as humidity, altitude, shock and vibration with an operating temperature ranges from -40°C to +85°C. Some models are also equipped with integrated heat sinks and cooling fans. Most designs are EAR99.
-
product
High Voltage Power Capacitors
Lifasa - International Capacitors, SA
Capacitors of correction power of cos φ and filtering of harmonics for AT of Lifasa, are manufactured under the base of the container / stainless steel box and porcelain terminals. There are two types, depending on the connection mode that we are going to use:*Single-phase (1 or 2 terminals) with internal fuses, for connection to the network through a double star. Recommended for networks of tension superior to 11 Kv or need of equipment of high power.*Three-phase (3 terminals) with internal fuses, for direct connection to three-phase network. Recommended for voltage networks lower than 11 Kv.
-
product
AC Power Source
LSP-500VAR
• AC-DC-AC frequency conversion technology, Controlled & tested by 16 bits MCU • Protection for over hot, thundering voltage and current • Total voltage distortion: ≤0.3%; Voltage stability: ≤0.05%/30min • Load adjust rate: ≤0.05%; Frequency stability: ≤0.01%/30min • Output voltage range: AC 0.0~300.0V, Output Frequency Range: 45~70Hz, 100Hz, 200Hz and 400Hz • It is pure sine wave AC power source with low harmonic and high accuracy • Input Power: 220V and 50/60Hz (110V can be option) • Communicate with PC via software, the Voltage & Current set by the software and Power Output can be remote controlled.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Phase Noise Measurement Up To 125 GHz
S930321B
S930321B enables phase noise measurements using a PNA or PNA-X vector network analyzer. Simplify your measurement workflow by measuring phase noise on the same connection as your network analysis measurement of 2-port active devices up to 125 GHz, without needing to connect a spectrum analyzer or harmonic mixer.
-
product
RF Front-end
The RF integrated passive device (RF IPD) uses a high-resistivity substrate to integrate quality factor components such as capacitors and indictors. Many functions like impedance matching networks, harmonic filters, couplers, baluns, and power combiners/splitters can be designed using IPD technology. ST's IPDs are manufactured using thick film and HiRes Si or glass wafer manufacturing technology and photolithography processing.
-
product
Power Quality Analyzers
GF334
Beijing GFUVE Electronics Co.,Ltd.
GF334 harmonics power analyzer is small size, handheld design, with current measurement directly from 0 to 20A, accuracy 0.05%, harmonics measurement from 2nd to 64th, display harmonic content and bar graph. As a high precision power analyzer.
-
product
Three-Phase AC Power Source 320 Vrms, 6 KVA, 5000 Hz
AC6906H
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Three-Phase AC Power Source 320 Vrms, 3 KVA, 5000 Hz
AC6903H
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
Three-Phase Relay Test Equipment
AK-6
*5 automatic or manual test modules: DC test, AC test, distance test, harmonics and frequency protection*Phase, frequency and amplitude are continuously and independently adjustable.*All-in-one design: built-in Windows CE & rotary encoder & keyboard & 6.4" TFT LCD (RJ45/USB for updates and downloads)*High power: 3x450VA at 0...35A average voltage test
-
product
Automated Tuners / Impedance Tuners / Load Pull Tuners
MT97x, MT98x and XT98x series automated tuners (also known as automated impedance tuners and automated load pull tuners) are precision instruments that are optimized for a broad class of in-fixture and on-wafer applications, and may be used in any automated or manual application requiring the ability to match the impedance of a microwave circuit element or to establish specific impedances at a terminal interface. The tuner design is based on the slide screw concept using the inherently broadband slab-line transmission structure. Each unit has two non-contacting probes deliver high VSWR with superb accuracy and reliability over a wide frequency range. These probes can be fully retracted leaving a low-loss, well-matched transmission line, which is a significant benefit in power related applications where two-port tuners capable of handling large amounts of power are required. As integral components of Maury Device Characterization Solutions, these PC-based tuners are controlled using Maury's family of Device Characterization Software tools, including MT930 IVCAD, MT993 ATS and the DLL-based measurement automation environment. Maury Microwave automed impedance tuners are ideal for load pull, harmonic load pull, active load pull, hybrid active load pull, noise figure, noise parameters and all automated tuner applications.
-
product
Capacitors And Reactors, LV
Wide range of cylindrical and prismatic capacitors for power factor correction in 50 or 60 Hz networks. Models with Heavy Duty system to ensure enhanced performance in extreme environments. Reactors are required to protect capacitors in installations with a high presence of harmonics, maintaining their characteristics and useful life without affecting their operation.
-
product
Test Analysis for Land Seismic Systems
Testif-i Land
Testif-i Land is an independent, powerful and cost effective software suite that allows you independently process instruments, source and receiver tests to confirm that the equipment is performing correctly and within specification. The software includes modules to perform comprehensive analysis of vibrator wireline similarity test data. Analysis includes a harmonic intensity plot which can highlight problems such as sub-harmonics which may not be seen on numerical results. Geophone pulse tests can be analysed using the receiver response module and test data from third party geophone testers can be graphed and statistics produced for ease of interpretation.
-
product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
product
Digital Arrester Clamp Tester
ALCL-40
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
product
sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781118-01
Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.





























