Transformer Oil
See Also: Oil Dielectric Test Set
-
Product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
-
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
Product
Split type AC Current Transformer
CTF-100T
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
Product
Transformer Turns Ratio Meters
-
Vanguard Instruments Company, Inc.
The ATRT-01 S3 is Vanguard’s fourth generation, micro-processor based, single phase, automatic transformer turns-ratio tester. The ATRT-01 S3 uses the IEEE C57.12.90 measuring method to determine the transformer turns-ratio. The transformer turns-ratio is determined by precisely measuring the voltages across the unloaded transformer windings. The ATRT-01 S3’s measuring circuitry self adjusts before each measurement to ensure turns-ratio accuracy. Two selectable test voltages, 4Vac and 40Vac, offer flexibility in testing different types of transformers.
-
Product
Upstream Oil & Gas Solutions
-
Measure, automate, and optimize your fieldAs a leader in automation to the oil and gas industry, ABB offers a complete solution of primary meters, transmitters and flow computers. ABB’s automation intelligence technology enables you to make more profit in a sustainable way.Whatever your application, ABB provides a wide range of instrumentation, analyzers and automation solutions for the upstream oil and gas chain to help you manage your operations safely, productively, and profitably.
-
Product
Voltage Transformer
-
Beijing GFUVE Electronics Co.,Ltd.
Are a parallel-connected type of instrument transformer. They are designed to present a negligible load to the supply being measured and have an accurate voltage ratio and phase relationship to enable accurate secondary connected metering.
-
Product
Oil in Water/Soil Analyzers
-
Oil in Water/Soil Analyzers simplify and streamline the on-site oil analysis process, so high-quality information and actionable intelligence leads to effective decision making.SPECTRO's Enterprise Fluid Intelligence offers two key product types: TruVu 360 and Online Training.
-
Product
Control Transformers
-
Osborne’s Control Transformers are commonly used to step down primary circuit voltages to lower voltages to be used for control circuit applications. These units set the standard for premium, high performance, hand crafted control transformers. Your customers will appreciate your decision to work with the quality and reliability of Osborne Transformer’s control transformers.
-
Product
Oil & Gas Single Stream Analyzers
Verax SSG & SSL
-
They provide rapid and reliable measurement of key compositional and physical properties for a wide variety of natural gas analysis (Verax SSG) and liquid (Verax SSL) applications in crude oil, condensates, NGLs and refined fuels.
-
Product
BMS Transformers
-
In large battery pack applications with daisy chain connections, the number of cells connected in series is very high, and the large voltage differences demand component-to-component isolation. The serial communication links between boards need to be isolated by transformer coupling circuits instead of capacitor coupling.
-
Product
Transformer & Capacitor Testers
-
*Quick and easy check for opens or shorts on transformers before energizing*Provides clear indications of open circuits, short connections and confirmation that the test results are OK*Tests overhead, pad-mount and other distribution transformers*Tests the primary and secondary sides of de‑energized transformers without disconnecting*Helps prevent line workers from installing a fuse on a shorted transformer*Automatic self-test feature*Magnet holds the tester in place while testing
-
Product
Transformer Turns Ratio Meter
-
We are considered as one of the leading manufacturers and exporters of Transformer Turns Ratio Meter With/ Without Phase. The equipment is widely used in power generation and engineering industry for testing of transformers. We engineer and develop this testing equipment in accordance with industry standards using best grade components and raw materials. This Transformer Turns Ratio Meter With/ Without Phase can be also optimized according to client's specific requirement. We offer this testing equipment at competitive price.
-
Product
Current Transformer
ST-9RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 800~2000
-
Product
Multiple Gas Transformer DGA
MULTITRANS
-
The MULTITRANS is an 8-gas on-line transformer DGA monitoring unit designed to monitor a bank of three single-phase transformers in close proximity. Based on the same core technology as the highly successful TRANSFIX the MULTITRANS measures all significant fault gases (in ppm) as outlined by international standards as well as moisture in oil (%RH & ppm).
-
Product
Current Transformer Test Set
-
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
Product
IC & Transformer
-
Mornsun Guangzhou Science & Technology
MORNSUN launched the self-designed electronic integrated circuits according to the different product lines, types of the integrated circuit include AC/DC power supply control ICs, DC/DC power supply control ICs, interface ICs, start-up ICs, contactor power saving controller ICs and digital isolator ICs. MORNSUN IC chip can be widely used in industrial equipment, process control, data acquisition system, building automation, smart meter, etc. Adopting MORNSUN's AC/DC transformers and DC/DC transformers, with the use of its control ICs, can achieve wide voltage input flyback power supply design with multiple protection functions and superior EMI performance. We hope that those power transformers along with the integrated circuits & chips electronics can be an ideal fit for your application needs.
-
Product
Single-Phase Transformer Winding Resistance Meters
RMO-TT Series
-
RMO-TT series is perfect for measuring winding resistance of inductive objects such as power and distribution transformers or autotransformers. Additionally, every transformer resistance meter from RMO-TT series can analyze:tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.Transformer demagnetization can also be performed with all RMO-TT instruments.The series is consisted of 3 models, with maximal test current from 40 A (RMO40TT) to 100 A (RMO100TT). RMO100TT is the only portable transformer resistance meter in the market with 100 A DC output current.The three independent channels enable testing of three windings in series. Consequently, a user can measure winding resistance in every tap position of an on-load tap changer without discharging between the tests.In addition to winding resistance measurement, a user can perform a detailed on-load tap changer analysis by analyzing recorded graphs (10 kHz sampling rate) and by measuring vibrations on an external tap changer tank.All RMO-TT instruments have a built-in tap changer control unit. Because of this, it is possible to remotely control on-load tap changer (OLTC) directly from the device. Also, a user can program DV-Win software to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Transformer Turns Ratio Tester
CX-BY
-
Shenzhen Chuangxin Instruments Co., Ltd.
It is to test voltage ratio, vector, polarity, ratio error of current transformer and voltage transformer.
-
Product
Complete Transformer Test Bench
-
Weshine Electric Manufacturing Co., Ltd
Our multifunction Transformer Test Bench (VS-ZHSY Series) is intuitive with all of the ease of working with individual, dedicated instruments. We deliver this experience through our design philosophy. Rather than producing a single, complex system with afterthought towards rendering it friendly, we uniquely combine several intelligent instruments packaged as a single system.
-
Product
AC Current Transformers
-
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
Product
ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
-
Chongqing Assen Power Equipment Co., Ltd
ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
-
Product
Transformer Resistance Testing
-
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the Megger Transformer Ohmmeter (MTO) series of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
Product
Automatic Liquid Interface Tension Meter,Surface Tension Analyzer,Oil Interface Tension Meter
-
Chongqing Assen Power Equipment Co., Ltd
Our HTID-1 Automatic Interface Tension Tester is used to test various liquid surface tension and interface tension based on the ring method that is simple and high accurate, which is widely applied in electric, petroleum, chemical, medicine, food, and teaching filed.
-
Product
Transformer Capacity Tester
-
Weshine Electric Manufacturing Co., Ltd
In many industries, including health care, manufacturing, electrical contracting, higher education and corrections, reliable, high-quality transformers are essential for keeping operations running efficiently. Large facilities and industrial processes require substantial amounts of power, and they need dependable transformers to convert the energy coming from the power plant into a form they can use for their equipment and building utilities.
-
Product
Electric Insulation Oil Automatic Measurement System
DAC-5016
-
DAC-5016 is an automatic test system of insulation oils according to JIS C-2101.The system automatically enables changing over samples (liquid cells) up to max 8 pieces and testing the dielectric loss tangents and the volume resistivities.In automatic mode, the dielectric loss tangents and the volume resistivities are automatically measured, and then the results are printed out with the built-in printer. And the relative permittivities and the volume resistivities calculated are also printed out. Therefore the test time is greatly saved compared to the conventional test methods.
-
Product
Current Transformers & Bushings
-
Measurements International Ltd.
AC Current Transformer, Reference Standard for the Calibration of Precision CTs, Currents as high as 10,000 A, Portable with carrying handle for smaller CTs, Wheels on heavier CTs, Passive or Electronically Aided Compensation.
-
Product
Portable Single Phase Transformer
-
Supreme Instrument Laboratories
Portable single phase double wound transformers both step-up and step-down, natural air cooled construction, housed in well ventilated sheet steel cabinet duly powder coated. All the input and output terminals are brought out and terminated on highly insulated bakelite panels duly marked for easy connection.
-
Product
Split type AC Current Transformer
CTS-200
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Short circuit switch for secondary output is provided for safe operation.*High accurate transformer for the application of first class meter.*Easy installation by metal fitting.
-
Product
Three-Phase Transformer Winding Resistance Meters
TWA Standard Series
-
When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.





























