Calibration References
A qualified quantified source of known value.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Calibration
-
General purpose calibration/diagnostic tool.Built in precision resistors.Simple manual contact/routing/resistor selection.4mm terminal posts on key device connections.In line mode to aid fixture wiring/DUT debugging.Comprehensive documentation including circuit schematics.Connecting cables.
-
Product
Calibration Devices For Spring Impact Hammer
CX-TF06A
-
Shenzhen Chuangxin Instruments Co., Ltd.
Calibration Devices for Spring Impact Hammer
-
Product
Velocity Calibration
-
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Temperature Calibrator
Model KM-CAL-906
-
Kusam Electrical Industries Limited
This temperature Calibrator gives high accuracy of 0.02% for measure and source. It has dual display, 5 digits for measure and 6 digits for source & white LED for backlight. Volts, RTD & Thermocouple. It gives output up to 500W to 5kW and output for calibrating R, S, K, E, J, T, N, B, L, U type of Thermocouples RTD & Continuity.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
-
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Optical Power Meter W/6 Wavelength Calibrating Spots
-
With six wavelength calibrating spots (980nm, 1310nm, 1490nm, 1550nm, 1590nm and 1610nm), refined design, easy operation, linearity or non-linearity display, SC connector, the MXOPM26-50 hand-held optical power meter can be used for direct optical power measurement as well as relative measurement of optical link loss. It’s an essential test instrument in Optical Communication systems, CATV systems, construction and maintenance applications and more.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (m) 50 Ohm
CK520A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
RF Calibration Kit
SMK-3000
-
The SMK calibration kits are precision, high power calibration standards that are used to calibrate RF radios, wattmeters, directional couplers and other high-power RF test equipment in the field or metrology lab. Unlike other calibration solutions, the SMK-3000 calibration kits reduce the cost of ownership and provide a much faster time-to-calibration with lab precision and accuracy you’ve come to expect from Bird.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
-
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Reference Solutions
-
As you seek solutions to evolving test challenges, Keysight Reference Solutions provide the right combination of hardware, software, and measurement expertise through programming examples highly optimized for specific applications. Reference Solutions show you how to get the most out of your test equipment, helping you achieve half the time to insight.
-
Product
Dry-Well Calibrators
-
Electronic Development Labs, Inc.
Portable, highly stable, and precise heat sources used to calibrate, test, and verify temperature sensors—such as thermocouples and resistance thermometers (RTDs)—without using oil or liquid baths.
-
Product
Calibration Pulse Processor
2401
-
TESCO’s Calibration Pulse Processor (Catalog No. 2401) adapts to any Next Generation three phase test board to directly calibrate with three independent single phase standards.
-
Product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Traditional Handheld Refractometer Calibration
104XXVP Series
-
Two-point NIST Traceable Certified Calibration for the following refractometers: 10430VP, 10431VP, 10433VP, and 10440VP.
-
Product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
-
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 26.5 GHz, 4-ports
N4433D
-
The Keysight N4433D RF electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4433D is a precision 4-ports ECal module that supports selection of 3.5 mm connector and can be mixed up to 26.5 GHz. Select either female-female, male-male, or female-male connectors.
-
Product
Calibration Measurement
-
The process of comparing a measuring instrument's readings to a known, more accurate standard to detect and correct errors.
-
Product
NI Real-Time Test Cell Reference System
778820-35
test
DIAdem Advanced with DAC Bundle, Perpetual License, Include 1 Year SSP
-
Product
Pressure Calibration Custom Systems
-
Our custom systems integrate standard Fluke Calibration products, pressure generation and control accessories and/or data acquisition hardware to meet customer requirements. Systems may be mobile calibration carts or rack mounted instrument panels or benches. 7250-sys Ruska gas pressure controller system, and engineered systems customized to fit your application needs.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Reference Magnet
-
Reference magnets generate a homogeneous magnetic field in an air gap. They are mainly used to calibrate hall probes for their full scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using reference magnets.
-
Product
Calibrator for Battery Charger-Analyzers
VCM-100
-
The VCM 100 is an instrument designed to verify the performance and to calibrate Battery Charger-Analyzers used on Nickel-Cadmium, Lead-Acid and other types of batteries.
-
Product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
-
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
Product
Volume Calibration
-
Trescal provides full Volume Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Volume Calibration services can be delivered at your site or at our lab. Accreditations for our volume calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.