Filter Results By:
Products
Applications
Manufacturers
-
product
Interface Converter
ZET 7070
Basic delivery scope with digital transducers for laboratory use includes the following: interface converter ZET 7070, power supply module 220V→ +24V, measuring line connector ZET 7001 (these components are mounted on a din-rail 300 mm); cable USB 2.0 A→B – length 1,8 m; terminal resistance 120 Ohm (for industrial use — steel plug); CD with ZETLAB SENSOR software, enabling connection of up to 60 digital sensors; set of operational documentation.
-
product
Analog Transducers
CR Magnetics Analog Transducers provide the easy to use tools to monitor any electrical power system, power supply, or electrical load. From simple DC to DC voltage transducers, to complex real and imaginary power transducers, CR Magnetics has the exact input, output, and sensing technology to meet the needs of any electrical power sensing application.
-
product
Power Line Transducers
Current Transducers measure AC Current and converts it to an industry standard output signal which is directly proportional to the measured input. These Transducers provide an output which is load independent and isolated from the input. The output can be connected to Controllers, Data-Loggers, PLC''''s, Analog / Digital Indicators, Recorders for display, analysis or control. They are ideal for SCADA, Energy Management, Telemetering for Remote, Local as well as Central Monitoring Systems.
-
product
Autonomous RTU
BSC-50E
Infinite Industrial Informatics Lt
BSC-50E is an ultra low power, wireless RTU with data logging and alarming capabilities. The battery powered RTU incorporates a quad band GSM/GPRS modem, four digital inputs, three analog inputs, two pulse counters and multiple excitation options for powering measuring transducers.
-
product
Autonomous RTUs
Infinite Industrial Informatics Lt
Autonomous RTUs are power network independent devices, opening up new horizons for telemetry in off-grid areas. An autonomous RTU features in measuring capabilities and contains a wireless MODEM for data and alarm transmission. It can also provide all necessary circuits for powering measuring transducers and sensors. The device is commonly powered by an internal battery and is housed in a IP66 to IP68 enclosure for outdoor use. The battery lifetime requirements extend from few months to 15 years. Another common requirement is continuous, maintenance free operation in harsh environmental conditions and extended temperature ranges.
-
product
Three Phase Power Meter
929A
Model 929A Three Phase Power Meter is an economical alternative to both the Model 931A Power System Analyzer and the Model 930A Three Phase Power Analyzer when serial communication, dc voltage measurement, transducer calibration and timer features are not required. The Model 929A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis, and is a complete diagnostic tool for use in the substation and industrial power environment.
-
product
Ultrasonic Transducers
Ultrasonic transducers send and receive waves for many types of sensing. Examples include distance, proximity, level, nondestructive evaluation, web break detection, counting, and security applications. They typically operate at their resonant frequency with various construction options, beam patterns, and power levels.
-
product
Power Measurements Conditioner
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
product
LED Power Driver ATS
8491
1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series
-
product
High Speed Data Acquisition
Data acquisition (DAQ) is the measurement, recording, analyzing, and presentation of real world phenomena. It includes electrical measurements such as voltage, current, power as well as measurements through sensors and transducers including temperature, pressure, flow, level, strain, acceleration, vibration, humidity, and more.
-
product
Three Phase Power Calibrators And Tester Of Power Engineering Devices
C300B
Calmet Smart Calibration Devices
Three phase, class 0.02 and 0.05 power quality calibrator up to 120A (360A) and 560VAC with programmable power quality parameters. It makes possible to make automatic test of electricity meters, measurement transducers, current transformers and protection relays.
-
product
Humidity Sensors
Humidity sensors can have analog, digital or video type displays and can have a number of different form factors. They can be PCB-mount devices, standard sensors or transducers, or a simple gauge or indicator. They can also be various types of instruments, whether handheld, benchtop or mounted.In addition to pressure and temperature compensation, humidity sensors can have a number of features to make them more useful or easier to use. Humidity sensors can include data logging, event triggering, self-testing, self-calibration, and battery power.
-
product
3-28V Cordless Circuit Tester
1948
Peaceful Thriving Enterprise Co Ltd
*With CE & UKCA Approvals.*Detect voltage from 3V to 28V.*No ground wire or clip required.*Replaceable long-life alkaline batteries included.(Power supply: SUM5 1.5V X 2 pc)*Safe with ECMs, sensors, transducers and air bags.
-
product
Power modules
G.R.A.S. Sound & Vibration A/S
It provides polarization voltage for the transducer, ensuring that the microphone gets the charging voltage it needs.It provides supply voltage for the microphone preamplifier. The preamplifier acts as a unity gain impedance converter. It provides a certain amount of line drive capability by providing a low output impedance and output current, making it possible to transmit the signal from the transducer to the Power Module without significant degradation.A power module can provide amplification or attenuation to the signal, thus making it possible to fine tune the measurement chain to the signals being measured and the hardware being used.Selectable filters make it possible to exclude unwanted noise from the measurement, e.g. wind induced noise from outdoor measurements.Overload detection makes it possible to validate the measurements and is a useful tool in monitoring setups.When a Power Module with gain is used, you can use longer cables because of the power module's ability to deliver current.A Power module introduces electrical isolation
-
product
Small Engine Dynamometers
Toroidal-flow water-brake absorber (with 5" high-RPM rotor), electronic torque-arm transducer, engine load control, DYNOmite handheld data-acquisition computer, AC power supply, stainless-braided hoses, magnetic RPM sensor, data wiring harness, and protective carrying case.
-
product
Precision Transducers
Transducers that cover the entire audio spectrum, combining absence of distortion with the ability to withstand high power levels over a long period of time.
-
product
Portable Digital Manometer
PS309
Featured are an integral variable reluctance transducer, solid state electronics module, 3 digit liquid crystal display (LCD)* and battery pack with six 1.5V penlight cells for truly portable operation. The units can also be powered from an external DC power supply or AC battery eliminator (converter) module. The transducer features all corrosion resistant materials in contact with the pressure media (both ports in differential units), very low internal cavity volumes and ultra-low volumetric displacement with full-scale pressure excursion. Transducer calibration is unaffected by dielectric properties of the sensed fluid. Gauge and differential transducers may be disassembled and range changed by simple diaphragm replacement.
-
product
Vibration Monitoring
Encore Electronics offers a full line of vibration monitoring equipment, ranging from DIN-rail mounted accelerometer signal conditioners to complete multi-channel monitor / alarm cabinets. Most are equipped with a 4mA power source for IEPE (Integral Electronic Piezo-Electric) transducers.
-
product
NI-9375 , 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module
781030-01
30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.
-
product
Ultrasonic NDT Transducers
United Western Technologies Corp
The Quick Change Transducer (QCT) series of transducers that makes changing wedge angle and transducer frequency rapid and easy, saving both time and money. The QCT connects straight into the wedges allowing for many combinations all within one kit. All QC Transducers are fitted with top mounted microdot connectors allowing for seamless transition from one transducer to the next. The stainless steel transducer housing will resist even the harshest working conditions. The emphasis of the QCT is general purpose with a balance of power and resolution, a High resolution version is available upon request.The Quick Change Wedge (QCW) is simple to setup and operate, utilizing incorporated noise dampening material on the wedge. Offered in steel, aluminum and titanium refracted angle. Custom contours, radii and wear pins available upon request.The QCT and QCW series are extremely versatile and can be used in many different applications and in a wide variety of industries and environments.
-
product
NI-9437, 24 VDC to 250 VDC, 8-Channel (Sinking Input), 1 µs C Series Digital Module
783393-02
24 VDC to 250 VDC, 8-Channel (Sinking Input), 1 µs C Series Digital Module - The NI‑9437 is well suited for direct connection in rail and power applications along with a wide array of industrial and automotive switches, transducers, and devices with high-voltage input needs. It features ratiometric thresholds that automatically adjust to 2/3 of the user supply voltage.
-
product
Flexible Current Sensor Probe
CTA
The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.
-
product
Automatic Relay Test Set
DRTS 64
DRTS 64 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 4 Voltage generators simultaneously available.
-
product
Current Clamps and Transducers
High-accuracy Current Sensors and TransducersHigh-accuracy sensors for AC/DC current measurement and power analysis. From current clamps to high-precision zero flux current transducers and Rogowsky coils.
-
product
Ruggedized Pressure Transducer
P24
The P24 Differential Pressure Transducer is the combination of a variable reluctance pressure transducer and a miniature carrier demodulator integrated into a single package to provide for operation from mobile dc power and deliver a standardized dc output suitable for recording or telemetry.
-
product
NI-9476, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module
NI-9476 / 779140-01
36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module - The NI‑9476 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 36 V, based on the external power supply, and features transient overvoltage protection between the output channels and the backplane. You can programmatically monitor the built-in overcurrent and short-circuit protection status of each channel.
-
product
Datum Universal Interface
DUI
Datum Electronics specifically designed the Universal Torque Sensor Interface which accepts serial data, displaying the output data and a wide range of additional analogue and digital outputs, s 4-20mA, +/-5Vdc, 0-5Vdc, +/-10Vdc, 0-10Vdc as well as RS232/485 serial data.The Datum Universal Interface (DUI) interfaces with all our rotary, static, reaction, digital torque sensors and torque transducers, as well as shaft power measurement solutions.
-
product
Split Core Current Transformers
Application:Watt Transducer, Current Transducer, KWH Meter, Demand Meter, Power Factor Meter, Current Sensing Relays, Energy Management SystemsContinuous Thermal: Rating 1.25 at 30° C, 1.0 at 55° C Standard 5-amp secondary. Others available.
-
product
Load Cell Transmitter
MODEL SST-LV
The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
product
sbRIO-9476 , Non-Enclosed, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module
783951-01
Non-Enclosed, 36 V, 32-Channel (Sourcing Output), 500 µs C Series Digital Module - The sbRIO‑9476 works with industrial logic levels and signals to connect directly to a wide array of industrial switches, transducers, and devices. Each channel is compatible with signals from 6 V to 36 V, based on the external power supply, and features transient overvoltage protection between the output channels and the backplane. You can programmatically monitor the built-in overcurrent and short-circuit protection status of each channel. Non-enclosed modules are designed for OEM applications.